Cargando…

“Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy

PURPOSE: Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the “dose of the day”. The purpose of this study is to investigate the “dose of the day”...

Descripción completa

Detalles Bibliográficos
Autores principales: Yuan, Zilong, Rong, Yi, Benedict, Stanley H., Daly, Megan E., Qiu, Jianfeng, Yamamoto, Tokihiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964750/
https://www.ncbi.nlm.nih.gov/pubmed/31816170
http://dx.doi.org/10.1002/acm2.12793
_version_ 1783488512671088640
author Yuan, Zilong
Rong, Yi
Benedict, Stanley H.
Daly, Megan E.
Qiu, Jianfeng
Yamamoto, Tokihiro
author_facet Yuan, Zilong
Rong, Yi
Benedict, Stanley H.
Daly, Megan E.
Qiu, Jianfeng
Yamamoto, Tokihiro
author_sort Yuan, Zilong
collection PubMed
description PURPOSE: Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the “dose of the day”. The purpose of this study is to investigate the “dose of the day” calculation accuracy based on CBCT and deformable image registration (DIR) for lung cancer radiotherapy. METHODS: A total of 12 lung cancer patients were identified, for which daily CBCT imaging was performed for treatment positioning. A re‐planning CT (rCT) was acquired after 20 Gy for all patients. A virtual CT (vCT) was created by deforming initial planning CT (pCT) to the simulated CBCT that was generated from deforming CBCT to rCT acquired on the same day. Treatment beams from the initial plan were copied to the vCT and rCT for dose calculation. Dosimetric agreement between vCT‐based and rCT‐based accumulated doses was evaluated using the Bland‐Altman analysis. RESULTS: Mean differences in dose‐volume metrics between vCT and rCT were smaller than 1.5%, and most discrepancies fell within the range of ± 5% for the target volume, lung, esophagus, and heart. For spinal cord D(max), a large mean difference of −5.55% was observed, which was largely attributed to very limited CBCT image quality (e.g., truncation artifacts). CONCLUSION: This study demonstrated a reasonable agreement in dose‐volume metrics between dose accumulation based on vCT and rCT, with the exception for cases with poor CBCT image quality. These findings suggest potential utility of vCT for providing a reasonable estimate of the “dose of the day”, and thus facilitating the process of ART for lung cancer.
format Online
Article
Text
id pubmed-6964750
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-69647502020-01-27 “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy Yuan, Zilong Rong, Yi Benedict, Stanley H. Daly, Megan E. Qiu, Jianfeng Yamamoto, Tokihiro J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the “dose of the day”. The purpose of this study is to investigate the “dose of the day” calculation accuracy based on CBCT and deformable image registration (DIR) for lung cancer radiotherapy. METHODS: A total of 12 lung cancer patients were identified, for which daily CBCT imaging was performed for treatment positioning. A re‐planning CT (rCT) was acquired after 20 Gy for all patients. A virtual CT (vCT) was created by deforming initial planning CT (pCT) to the simulated CBCT that was generated from deforming CBCT to rCT acquired on the same day. Treatment beams from the initial plan were copied to the vCT and rCT for dose calculation. Dosimetric agreement between vCT‐based and rCT‐based accumulated doses was evaluated using the Bland‐Altman analysis. RESULTS: Mean differences in dose‐volume metrics between vCT and rCT were smaller than 1.5%, and most discrepancies fell within the range of ± 5% for the target volume, lung, esophagus, and heart. For spinal cord D(max), a large mean difference of −5.55% was observed, which was largely attributed to very limited CBCT image quality (e.g., truncation artifacts). CONCLUSION: This study demonstrated a reasonable agreement in dose‐volume metrics between dose accumulation based on vCT and rCT, with the exception for cases with poor CBCT image quality. These findings suggest potential utility of vCT for providing a reasonable estimate of the “dose of the day”, and thus facilitating the process of ART for lung cancer. John Wiley and Sons Inc. 2019-12-09 /pmc/articles/PMC6964750/ /pubmed/31816170 http://dx.doi.org/10.1002/acm2.12793 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Yuan, Zilong
Rong, Yi
Benedict, Stanley H.
Daly, Megan E.
Qiu, Jianfeng
Yamamoto, Tokihiro
“Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
title “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
title_full “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
title_fullStr “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
title_full_unstemmed “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
title_short “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
title_sort “dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964750/
https://www.ncbi.nlm.nih.gov/pubmed/31816170
http://dx.doi.org/10.1002/acm2.12793
work_keys_str_mv AT yuanzilong doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy
AT rongyi doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy
AT benedictstanleyh doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy
AT dalymegane doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy
AT qiujianfeng doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy
AT yamamototokihiro doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy