Cargando…
“Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
PURPOSE: Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the “dose of the day”. The purpose of this study is to investigate the “dose of the day”...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964750/ https://www.ncbi.nlm.nih.gov/pubmed/31816170 http://dx.doi.org/10.1002/acm2.12793 |
_version_ | 1783488512671088640 |
---|---|
author | Yuan, Zilong Rong, Yi Benedict, Stanley H. Daly, Megan E. Qiu, Jianfeng Yamamoto, Tokihiro |
author_facet | Yuan, Zilong Rong, Yi Benedict, Stanley H. Daly, Megan E. Qiu, Jianfeng Yamamoto, Tokihiro |
author_sort | Yuan, Zilong |
collection | PubMed |
description | PURPOSE: Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the “dose of the day”. The purpose of this study is to investigate the “dose of the day” calculation accuracy based on CBCT and deformable image registration (DIR) for lung cancer radiotherapy. METHODS: A total of 12 lung cancer patients were identified, for which daily CBCT imaging was performed for treatment positioning. A re‐planning CT (rCT) was acquired after 20 Gy for all patients. A virtual CT (vCT) was created by deforming initial planning CT (pCT) to the simulated CBCT that was generated from deforming CBCT to rCT acquired on the same day. Treatment beams from the initial plan were copied to the vCT and rCT for dose calculation. Dosimetric agreement between vCT‐based and rCT‐based accumulated doses was evaluated using the Bland‐Altman analysis. RESULTS: Mean differences in dose‐volume metrics between vCT and rCT were smaller than 1.5%, and most discrepancies fell within the range of ± 5% for the target volume, lung, esophagus, and heart. For spinal cord D(max), a large mean difference of −5.55% was observed, which was largely attributed to very limited CBCT image quality (e.g., truncation artifacts). CONCLUSION: This study demonstrated a reasonable agreement in dose‐volume metrics between dose accumulation based on vCT and rCT, with the exception for cases with poor CBCT image quality. These findings suggest potential utility of vCT for providing a reasonable estimate of the “dose of the day”, and thus facilitating the process of ART for lung cancer. |
format | Online Article Text |
id | pubmed-6964750 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-69647502020-01-27 “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy Yuan, Zilong Rong, Yi Benedict, Stanley H. Daly, Megan E. Qiu, Jianfeng Yamamoto, Tokihiro J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the “dose of the day”. The purpose of this study is to investigate the “dose of the day” calculation accuracy based on CBCT and deformable image registration (DIR) for lung cancer radiotherapy. METHODS: A total of 12 lung cancer patients were identified, for which daily CBCT imaging was performed for treatment positioning. A re‐planning CT (rCT) was acquired after 20 Gy for all patients. A virtual CT (vCT) was created by deforming initial planning CT (pCT) to the simulated CBCT that was generated from deforming CBCT to rCT acquired on the same day. Treatment beams from the initial plan were copied to the vCT and rCT for dose calculation. Dosimetric agreement between vCT‐based and rCT‐based accumulated doses was evaluated using the Bland‐Altman analysis. RESULTS: Mean differences in dose‐volume metrics between vCT and rCT were smaller than 1.5%, and most discrepancies fell within the range of ± 5% for the target volume, lung, esophagus, and heart. For spinal cord D(max), a large mean difference of −5.55% was observed, which was largely attributed to very limited CBCT image quality (e.g., truncation artifacts). CONCLUSION: This study demonstrated a reasonable agreement in dose‐volume metrics between dose accumulation based on vCT and rCT, with the exception for cases with poor CBCT image quality. These findings suggest potential utility of vCT for providing a reasonable estimate of the “dose of the day”, and thus facilitating the process of ART for lung cancer. John Wiley and Sons Inc. 2019-12-09 /pmc/articles/PMC6964750/ /pubmed/31816170 http://dx.doi.org/10.1002/acm2.12793 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Yuan, Zilong Rong, Yi Benedict, Stanley H. Daly, Megan E. Qiu, Jianfeng Yamamoto, Tokihiro “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy |
title | “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy |
title_full | “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy |
title_fullStr | “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy |
title_full_unstemmed | “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy |
title_short | “Dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy |
title_sort | “dose of the day” based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964750/ https://www.ncbi.nlm.nih.gov/pubmed/31816170 http://dx.doi.org/10.1002/acm2.12793 |
work_keys_str_mv | AT yuanzilong doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy AT rongyi doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy AT benedictstanleyh doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy AT dalymegane doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy AT qiujianfeng doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy AT yamamototokihiro doseofthedaybasedonconebeamcomputedtomographyanddeformableimageregistrationforlungcancerradiotherapy |