The use of 0.5r(cav) as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses

Electron dosimetry can be performed using cylindrical chambers, plane‐parallel chambers, and diode detectors. The finite volume of these detectors results in a displacement effect which is taken into account using an effective point of measurement (EPOM). Dosimetry protocols have recommended a shift...

Descripción completa

Detalles Bibliográficos
Autores principales: Anusionwu, Princess C., Alpuche Aviles, Jorge E., Pistorius, Stephen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964751/
https://www.ncbi.nlm.nih.gov/pubmed/31898872
http://dx.doi.org/10.1002/acm2.12797
_version_ 1783488512909115392
author Anusionwu, Princess C.
Alpuche Aviles, Jorge E.
Pistorius, Stephen
author_facet Anusionwu, Princess C.
Alpuche Aviles, Jorge E.
Pistorius, Stephen
author_sort Anusionwu, Princess C.
collection PubMed
description Electron dosimetry can be performed using cylindrical chambers, plane‐parallel chambers, and diode detectors. The finite volume of these detectors results in a displacement effect which is taken into account using an effective point of measurement (EPOM). Dosimetry protocols have recommended a shift of 0.5 r(cav) for cylindrical chambers; however, various studies have shown that the optimal shift may deviate from this recommended value. This study investigated the effect that the selection of EPOM shift for cylindrical chamber has on percentage depth dose (PDD) curves. Depth dose curves were measured in a water phantom for electron beams with energies ranging from 6 to 18 MeV. The detectors investigated were of three different types: diodes (Diode‐E PTW 60017 and SFD IBA), cylindrical (Semiflex PTW 31010, PinPoint PTW 31015, and A12 Exradin), and parallel plate ionization chambers (Advanced Markus PTW 34045 and Markus PTW 23343). Depth dose curves measured with Diode‐E and Advanced Markus agreed within 0.2 mm at R(50) except for 18 MeV and extremely large field size. The PDDs measured with the Semiflex chamber and Exradin A12 were about 1.1 mm (with respect to the Advanced Markus chamber) shallower than those measured with the other detectors using a 0.5 r(cav) shift. The difference between the PDDs decreased when a Pinpoint chamber, with a smaller cavity radius, was used. Agreement improved at lower energies, with the use of previously published EPOM corrections (0.3 r(cav)). Therefore, the use of 0.5 r(cav) as an EPOM may result in a systematic shift of the therapeutic portion of the PDD (distances < R(90)). Our results suggest that a 0.1 r(cav) shift is more appropriate for one chamber model (Semiflex PTW 31010).
format Online
Article
Text
id pubmed-6964751
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-69647512020-01-27 The use of 0.5r(cav) as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses Anusionwu, Princess C. Alpuche Aviles, Jorge E. Pistorius, Stephen J Appl Clin Med Phys Radiation Measurements Electron dosimetry can be performed using cylindrical chambers, plane‐parallel chambers, and diode detectors. The finite volume of these detectors results in a displacement effect which is taken into account using an effective point of measurement (EPOM). Dosimetry protocols have recommended a shift of 0.5 r(cav) for cylindrical chambers; however, various studies have shown that the optimal shift may deviate from this recommended value. This study investigated the effect that the selection of EPOM shift for cylindrical chamber has on percentage depth dose (PDD) curves. Depth dose curves were measured in a water phantom for electron beams with energies ranging from 6 to 18 MeV. The detectors investigated were of three different types: diodes (Diode‐E PTW 60017 and SFD IBA), cylindrical (Semiflex PTW 31010, PinPoint PTW 31015, and A12 Exradin), and parallel plate ionization chambers (Advanced Markus PTW 34045 and Markus PTW 23343). Depth dose curves measured with Diode‐E and Advanced Markus agreed within 0.2 mm at R(50) except for 18 MeV and extremely large field size. The PDDs measured with the Semiflex chamber and Exradin A12 were about 1.1 mm (with respect to the Advanced Markus chamber) shallower than those measured with the other detectors using a 0.5 r(cav) shift. The difference between the PDDs decreased when a Pinpoint chamber, with a smaller cavity radius, was used. Agreement improved at lower energies, with the use of previously published EPOM corrections (0.3 r(cav)). Therefore, the use of 0.5 r(cav) as an EPOM may result in a systematic shift of the therapeutic portion of the PDD (distances < R(90)). Our results suggest that a 0.1 r(cav) shift is more appropriate for one chamber model (Semiflex PTW 31010). John Wiley and Sons Inc. 2020-01-03 /pmc/articles/PMC6964751/ /pubmed/31898872 http://dx.doi.org/10.1002/acm2.12797 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Measurements
Anusionwu, Princess C.
Alpuche Aviles, Jorge E.
Pistorius, Stephen
The use of 0.5r(cav) as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses
title The use of 0.5r(cav) as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses
title_full The use of 0.5r(cav) as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses
title_fullStr The use of 0.5r(cav) as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses
title_full_unstemmed The use of 0.5r(cav) as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses
title_short The use of 0.5r(cav) as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses
title_sort use of 0.5r(cav) as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses
topic Radiation Measurements
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964751/
https://www.ncbi.nlm.nih.gov/pubmed/31898872
http://dx.doi.org/10.1002/acm2.12797
work_keys_str_mv AT anusionwuprincessc theuseof05rcavasaneffectivepointofmeasurementforcylindricalchambersmayresultinasystematicshiftofelectronpercentagedepthdoses
AT alpucheavilesjorgee theuseof05rcavasaneffectivepointofmeasurementforcylindricalchambersmayresultinasystematicshiftofelectronpercentagedepthdoses
AT pistoriusstephen theuseof05rcavasaneffectivepointofmeasurementforcylindricalchambersmayresultinasystematicshiftofelectronpercentagedepthdoses
AT anusionwuprincessc useof05rcavasaneffectivepointofmeasurementforcylindricalchambersmayresultinasystematicshiftofelectronpercentagedepthdoses
AT alpucheavilesjorgee useof05rcavasaneffectivepointofmeasurementforcylindricalchambersmayresultinasystematicshiftofelectronpercentagedepthdoses
AT pistoriusstephen useof05rcavasaneffectivepointofmeasurementforcylindricalchambersmayresultinasystematicshiftofelectronpercentagedepthdoses