A self‐checking treatment couch coordinate calculation system in radiotherapy

PURPOSE: Traditionally, the treatment couch coordinates (TCCs) for patients undergoing radiotherapy can only be determined at the time of treatment, placing pressure on the treating therapists and leaving several pathways for errors such as wrong‐site treatment or wrong treatment table shift from a...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsai, Pingfang, Liu, Chihray, Kahler, Darren L., Li, Jonathan G., Lu, Bo, Yan, Guanghua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964758/
https://www.ncbi.nlm.nih.gov/pubmed/31737999
http://dx.doi.org/10.1002/acm2.12771
_version_ 1783488514634022912
author Tsai, Pingfang
Liu, Chihray
Kahler, Darren L.
Li, Jonathan G.
Lu, Bo
Yan, Guanghua
author_facet Tsai, Pingfang
Liu, Chihray
Kahler, Darren L.
Li, Jonathan G.
Lu, Bo
Yan, Guanghua
author_sort Tsai, Pingfang
collection PubMed
description PURPOSE: Traditionally, the treatment couch coordinates (TCCs) for patients undergoing radiotherapy can only be determined at the time of treatment, placing pressure on the treating therapists and leaving several pathways for errors such as wrong‐site treatment or wrong treatment table shift from a reference point. The purpose of this work is to propose an accurate, robust, and streamlined system that calculates TCC in advance. METHODS: The proposed system combines the advantages of two different calculation methods that use an indexed immobilization device. The first method uses an array of reference ball bearings (BBs) embedded in the CT scanner’s couch‐top. To obtain the patient‐specific TCC, the spatial offset of the treatment planning isocenter from the reference BB is used. The second method performs a calculation using the one‐to‐one mapping relationship between the CT scanner’s DICOM (Digital Imaging and Communications in Medicine) coordinate system and the TCC system. Both methods use a reference point in the CT coordinate system to correlate a point in the TCC system to perform the coordinate transfer between the two systems. Both methods were used to calculate the TCC and the results were checked against each other, creating an integrated workflow via automated self‐checking. The accuracy of the calculation system was retrospectively evaluated with 275 patients, where the actual treatment position determined with cone‐beam CT was used as a reference. RESULTS: An efficient workflow transparent to the therapists at both CT simulation and treatment was created. It works with any indexed immobilization device and can be universally applied to all treatment sites. The two methods had comparable accuracy, with 95% of the calculations within 3 mm. The inter‐fraction variation was within ± 1.0 cm for 95% of the coordinates across all the treatment sites. CONCLUSIONS: A robust, accurate, and streamlined system was implemented to calculate TCCs in advance. It eases the pressure on the treating therapists, reduces patient setup time, and enhances the patient safety by preventing setup errors.
format Online
Article
Text
id pubmed-6964758
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-69647582020-01-27 A self‐checking treatment couch coordinate calculation system in radiotherapy Tsai, Pingfang Liu, Chihray Kahler, Darren L. Li, Jonathan G. Lu, Bo Yan, Guanghua J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: Traditionally, the treatment couch coordinates (TCCs) for patients undergoing radiotherapy can only be determined at the time of treatment, placing pressure on the treating therapists and leaving several pathways for errors such as wrong‐site treatment or wrong treatment table shift from a reference point. The purpose of this work is to propose an accurate, robust, and streamlined system that calculates TCC in advance. METHODS: The proposed system combines the advantages of two different calculation methods that use an indexed immobilization device. The first method uses an array of reference ball bearings (BBs) embedded in the CT scanner’s couch‐top. To obtain the patient‐specific TCC, the spatial offset of the treatment planning isocenter from the reference BB is used. The second method performs a calculation using the one‐to‐one mapping relationship between the CT scanner’s DICOM (Digital Imaging and Communications in Medicine) coordinate system and the TCC system. Both methods use a reference point in the CT coordinate system to correlate a point in the TCC system to perform the coordinate transfer between the two systems. Both methods were used to calculate the TCC and the results were checked against each other, creating an integrated workflow via automated self‐checking. The accuracy of the calculation system was retrospectively evaluated with 275 patients, where the actual treatment position determined with cone‐beam CT was used as a reference. RESULTS: An efficient workflow transparent to the therapists at both CT simulation and treatment was created. It works with any indexed immobilization device and can be universally applied to all treatment sites. The two methods had comparable accuracy, with 95% of the calculations within 3 mm. The inter‐fraction variation was within ± 1.0 cm for 95% of the coordinates across all the treatment sites. CONCLUSIONS: A robust, accurate, and streamlined system was implemented to calculate TCCs in advance. It eases the pressure on the treating therapists, reduces patient setup time, and enhances the patient safety by preventing setup errors. John Wiley and Sons Inc. 2019-11-18 /pmc/articles/PMC6964758/ /pubmed/31737999 http://dx.doi.org/10.1002/acm2.12771 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Tsai, Pingfang
Liu, Chihray
Kahler, Darren L.
Li, Jonathan G.
Lu, Bo
Yan, Guanghua
A self‐checking treatment couch coordinate calculation system in radiotherapy
title A self‐checking treatment couch coordinate calculation system in radiotherapy
title_full A self‐checking treatment couch coordinate calculation system in radiotherapy
title_fullStr A self‐checking treatment couch coordinate calculation system in radiotherapy
title_full_unstemmed A self‐checking treatment couch coordinate calculation system in radiotherapy
title_short A self‐checking treatment couch coordinate calculation system in radiotherapy
title_sort self‐checking treatment couch coordinate calculation system in radiotherapy
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964758/
https://www.ncbi.nlm.nih.gov/pubmed/31737999
http://dx.doi.org/10.1002/acm2.12771
work_keys_str_mv AT tsaipingfang aselfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT liuchihray aselfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT kahlerdarrenl aselfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT lijonathang aselfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT lubo aselfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT yanguanghua aselfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT tsaipingfang selfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT liuchihray selfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT kahlerdarrenl selfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT lijonathang selfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT lubo selfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy
AT yanguanghua selfcheckingtreatmentcouchcoordinatecalculationsysteminradiotherapy