Cargando…
Treatment planning of VMAT and step‐and‐shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom‐based quality assurance measurements
PURPOSE: To retrospectively compare clinically treated step‐and‐shoot intensity modulated radiotherapy (ssIMRT) and volumetric modulated arc therapy (VMAT) spine stereotactic body radiotherapy (SBRT) plans in dosimetric endpoints and pretreatment quality assurance (QA) measurements. METHODS: Five si...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964769/ https://www.ncbi.nlm.nih.gov/pubmed/31821729 http://dx.doi.org/10.1002/acm2.12788 |
_version_ | 1783488517015339008 |
---|---|
author | Ouyang, Zi LaHurd, Danielle V. Balagamwala, Ehsan H. Chao, Samuel T. Suh, John H. Xia, Ping |
author_facet | Ouyang, Zi LaHurd, Danielle V. Balagamwala, Ehsan H. Chao, Samuel T. Suh, John H. Xia, Ping |
author_sort | Ouyang, Zi |
collection | PubMed |
description | PURPOSE: To retrospectively compare clinically treated step‐and‐shoot intensity modulated radiotherapy (ssIMRT) and volumetric modulated arc therapy (VMAT) spine stereotactic body radiotherapy (SBRT) plans in dosimetric endpoints and pretreatment quality assurance (QA) measurements. METHODS: Five single fraction spine SBRT (18 Gy) cases — including one cervical, two thoracic, and two lumbar spines — clinically treated with ssIMRT were replanned with VMAT, and all plans were delivered to a phantom for comparing plan quality and delivery accuracy. Furthermore, we analyzed 98 clinically treated plans (18 Gy single fraction), including 34 ssIMRT and 29 VMAT for cervical/thoracic spine, and 19 ssIMRT and 16 VMAT for lumbar spine. The conformality index (CI) and homogeneity index (HI) were calculated, and QA measurement records were compared. For the spinal cord/cauda equina, the maximum dose to 0.03 cc (D(0.03cc)) and volume receiving 10 or 12 Gy (V(10Gy)/V(12Gy)) were recorded. Statistical significance was tested with the Mann–Whitney U test. RESULTS: Compared to ssIMRT, replanned VMAT plans had lower V(10Gy)/V(12Gy) and D(0.03cc) to the spinal cord/cauda equina in all five cases, and better CI in three out of five cases. The VMAT replans were slightly less homogeneous than those of ssIMRT plans. Both modalities passed IMRT QA with >95% passing rate with (3%, 3 mm) gamma criteria. With the 98 clinical cases, for cervical/thoracic ssIMRT and VMAT plans, the median V(10Gy) of spinal cord was 4.15% and 1.85% (P = 0.004); the median D(0.03cc) of spinal cord was 10.85 Gy and 10.10 Gy (P = 0.032); the median CI was 1.28 and 1.08 (P = 0.009); the median HI were 1.34 and 1.33 (P = 0.697), respectively. For lumbar spine, no significant dosimetric endpoint differences were observed. The two modalities were comparable in delivery accuracy. CONCLUSION: From our clinically treated plans, we found that VMAT plans provided better dosimetric quality and comparable delivery accuracy when compared to ssIMRT for single fraction spine SBRT. |
format | Online Article Text |
id | pubmed-6964769 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-69647692020-01-27 Treatment planning of VMAT and step‐and‐shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom‐based quality assurance measurements Ouyang, Zi LaHurd, Danielle V. Balagamwala, Ehsan H. Chao, Samuel T. Suh, John H. Xia, Ping J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To retrospectively compare clinically treated step‐and‐shoot intensity modulated radiotherapy (ssIMRT) and volumetric modulated arc therapy (VMAT) spine stereotactic body radiotherapy (SBRT) plans in dosimetric endpoints and pretreatment quality assurance (QA) measurements. METHODS: Five single fraction spine SBRT (18 Gy) cases — including one cervical, two thoracic, and two lumbar spines — clinically treated with ssIMRT were replanned with VMAT, and all plans were delivered to a phantom for comparing plan quality and delivery accuracy. Furthermore, we analyzed 98 clinically treated plans (18 Gy single fraction), including 34 ssIMRT and 29 VMAT for cervical/thoracic spine, and 19 ssIMRT and 16 VMAT for lumbar spine. The conformality index (CI) and homogeneity index (HI) were calculated, and QA measurement records were compared. For the spinal cord/cauda equina, the maximum dose to 0.03 cc (D(0.03cc)) and volume receiving 10 or 12 Gy (V(10Gy)/V(12Gy)) were recorded. Statistical significance was tested with the Mann–Whitney U test. RESULTS: Compared to ssIMRT, replanned VMAT plans had lower V(10Gy)/V(12Gy) and D(0.03cc) to the spinal cord/cauda equina in all five cases, and better CI in three out of five cases. The VMAT replans were slightly less homogeneous than those of ssIMRT plans. Both modalities passed IMRT QA with >95% passing rate with (3%, 3 mm) gamma criteria. With the 98 clinical cases, for cervical/thoracic ssIMRT and VMAT plans, the median V(10Gy) of spinal cord was 4.15% and 1.85% (P = 0.004); the median D(0.03cc) of spinal cord was 10.85 Gy and 10.10 Gy (P = 0.032); the median CI was 1.28 and 1.08 (P = 0.009); the median HI were 1.34 and 1.33 (P = 0.697), respectively. For lumbar spine, no significant dosimetric endpoint differences were observed. The two modalities were comparable in delivery accuracy. CONCLUSION: From our clinically treated plans, we found that VMAT plans provided better dosimetric quality and comparable delivery accuracy when compared to ssIMRT for single fraction spine SBRT. John Wiley and Sons Inc. 2019-12-10 /pmc/articles/PMC6964769/ /pubmed/31821729 http://dx.doi.org/10.1002/acm2.12788 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Ouyang, Zi LaHurd, Danielle V. Balagamwala, Ehsan H. Chao, Samuel T. Suh, John H. Xia, Ping Treatment planning of VMAT and step‐and‐shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom‐based quality assurance measurements |
title | Treatment planning of VMAT and step‐and‐shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom‐based quality assurance measurements |
title_full | Treatment planning of VMAT and step‐and‐shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom‐based quality assurance measurements |
title_fullStr | Treatment planning of VMAT and step‐and‐shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom‐based quality assurance measurements |
title_full_unstemmed | Treatment planning of VMAT and step‐and‐shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom‐based quality assurance measurements |
title_short | Treatment planning of VMAT and step‐and‐shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom‐based quality assurance measurements |
title_sort | treatment planning of vmat and step‐and‐shoot imrt delivery techniques for single fraction spine sbrt: an intercomparative dosimetric analysis and phantom‐based quality assurance measurements |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6964769/ https://www.ncbi.nlm.nih.gov/pubmed/31821729 http://dx.doi.org/10.1002/acm2.12788 |
work_keys_str_mv | AT ouyangzi treatmentplanningofvmatandstepandshootimrtdeliverytechniquesforsinglefractionspinesbrtanintercomparativedosimetricanalysisandphantombasedqualityassurancemeasurements AT lahurddaniellev treatmentplanningofvmatandstepandshootimrtdeliverytechniquesforsinglefractionspinesbrtanintercomparativedosimetricanalysisandphantombasedqualityassurancemeasurements AT balagamwalaehsanh treatmentplanningofvmatandstepandshootimrtdeliverytechniquesforsinglefractionspinesbrtanintercomparativedosimetricanalysisandphantombasedqualityassurancemeasurements AT chaosamuelt treatmentplanningofvmatandstepandshootimrtdeliverytechniquesforsinglefractionspinesbrtanintercomparativedosimetricanalysisandphantombasedqualityassurancemeasurements AT suhjohnh treatmentplanningofvmatandstepandshootimrtdeliverytechniquesforsinglefractionspinesbrtanintercomparativedosimetricanalysisandphantombasedqualityassurancemeasurements AT xiaping treatmentplanningofvmatandstepandshootimrtdeliverytechniquesforsinglefractionspinesbrtanintercomparativedosimetricanalysisandphantombasedqualityassurancemeasurements |