Cargando…

The influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials

OBJECTIVES: To evaluate the elastic recovery of a typical irreversible hydrocolloid impression material in terms of the amount of undercut identified and additional thickness of spacer provided before custom tray fabrication. METHODS: This study surveyed the undercut depths of the teeth surfaces and...

Descripción completa

Detalles Bibliográficos
Autores principales: Mudliar, Vidya Latchmi, Li, Kai Chun, van Vuuren, Ludwig Jansen, Waddell, John Neil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6965733/
https://www.ncbi.nlm.nih.gov/pubmed/31970297
http://dx.doi.org/10.1016/j.heliyon.2019.e03143
_version_ 1783488671317491712
author Mudliar, Vidya Latchmi
Li, Kai Chun
van Vuuren, Ludwig Jansen
Waddell, John Neil
author_facet Mudliar, Vidya Latchmi
Li, Kai Chun
van Vuuren, Ludwig Jansen
Waddell, John Neil
author_sort Mudliar, Vidya Latchmi
collection PubMed
description OBJECTIVES: To evaluate the elastic recovery of a typical irreversible hydrocolloid impression material in terms of the amount of undercut identified and additional thickness of spacer provided before custom tray fabrication. METHODS: This study surveyed the undercut depths of the teeth surfaces and lingual sulci of one hundred partially dentate mandibular dental casts which were subsequently scanned and the data exported as STL files. A typical cast from each undercut category (0.5mm, 1mm, 1.5mm, 2mm, 2.5mm, 3mm, 4mm, 5mm) was 3D printed. Three custom trays were constructed with spacer thicknesses representing 20%, 30% and 50% compression against the wall of the custom trays on removal, impressions recorded, and casts fabricated in dental stone. Measurements for elastic recovery of irreversible hydrocolloid were done using an internal caliper and a digital caliper. All measurements were done by the principal investigator. Non-parametric analyses were used for comparisons of the undercut values between the 3D printed and poured casts to determine the amount of elastic recovery of the irreversible hydrocolloid impression material. RESULTS: There was no statistically significant difference in measurements between the original 3D printed casts and the poured casts, irrespective of percentage compression (p [Formula: see text] 0.05). CONCLUSIONS: In removable partial denture construction, casts should be blocked out parallel to the path of insertion and then an additional 3mm of spacer applied as a standard technique before custom tray fabrication to ensure elastic recovery of the irreversible hydrocolloid impression. CLINICAL IMPLICATIONS: In severe undercut situations, accurate impressions can be taken using irreversible hydrocolloid by blocking out all undercut surfaces on the teeth and lingual sulci before adapting additional three-millimetre wax spacer on casts when constructing custom trays thereby ensuring accurate and reliable impressions for removable prosthesis construction.
format Online
Article
Text
id pubmed-6965733
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-69657332020-01-22 The influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials Mudliar, Vidya Latchmi Li, Kai Chun van Vuuren, Ludwig Jansen Waddell, John Neil Heliyon Article OBJECTIVES: To evaluate the elastic recovery of a typical irreversible hydrocolloid impression material in terms of the amount of undercut identified and additional thickness of spacer provided before custom tray fabrication. METHODS: This study surveyed the undercut depths of the teeth surfaces and lingual sulci of one hundred partially dentate mandibular dental casts which were subsequently scanned and the data exported as STL files. A typical cast from each undercut category (0.5mm, 1mm, 1.5mm, 2mm, 2.5mm, 3mm, 4mm, 5mm) was 3D printed. Three custom trays were constructed with spacer thicknesses representing 20%, 30% and 50% compression against the wall of the custom trays on removal, impressions recorded, and casts fabricated in dental stone. Measurements for elastic recovery of irreversible hydrocolloid were done using an internal caliper and a digital caliper. All measurements were done by the principal investigator. Non-parametric analyses were used for comparisons of the undercut values between the 3D printed and poured casts to determine the amount of elastic recovery of the irreversible hydrocolloid impression material. RESULTS: There was no statistically significant difference in measurements between the original 3D printed casts and the poured casts, irrespective of percentage compression (p [Formula: see text] 0.05). CONCLUSIONS: In removable partial denture construction, casts should be blocked out parallel to the path of insertion and then an additional 3mm of spacer applied as a standard technique before custom tray fabrication to ensure elastic recovery of the irreversible hydrocolloid impression. CLINICAL IMPLICATIONS: In severe undercut situations, accurate impressions can be taken using irreversible hydrocolloid by blocking out all undercut surfaces on the teeth and lingual sulci before adapting additional three-millimetre wax spacer on casts when constructing custom trays thereby ensuring accurate and reliable impressions for removable prosthesis construction. Elsevier 2020-01-14 /pmc/articles/PMC6965733/ /pubmed/31970297 http://dx.doi.org/10.1016/j.heliyon.2019.e03143 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Mudliar, Vidya Latchmi
Li, Kai Chun
van Vuuren, Ludwig Jansen
Waddell, John Neil
The influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials
title The influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials
title_full The influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials
title_fullStr The influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials
title_full_unstemmed The influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials
title_short The influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials
title_sort influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6965733/
https://www.ncbi.nlm.nih.gov/pubmed/31970297
http://dx.doi.org/10.1016/j.heliyon.2019.e03143
work_keys_str_mv AT mudliarvidyalatchmi theinfluenceofundercutdepthsontheaccuracyofcastspouredfromirreversiblehydrocolloidimpressionmaterials
AT likaichun theinfluenceofundercutdepthsontheaccuracyofcastspouredfromirreversiblehydrocolloidimpressionmaterials
AT vanvuurenludwigjansen theinfluenceofundercutdepthsontheaccuracyofcastspouredfromirreversiblehydrocolloidimpressionmaterials
AT waddelljohnneil theinfluenceofundercutdepthsontheaccuracyofcastspouredfromirreversiblehydrocolloidimpressionmaterials
AT mudliarvidyalatchmi influenceofundercutdepthsontheaccuracyofcastspouredfromirreversiblehydrocolloidimpressionmaterials
AT likaichun influenceofundercutdepthsontheaccuracyofcastspouredfromirreversiblehydrocolloidimpressionmaterials
AT vanvuurenludwigjansen influenceofundercutdepthsontheaccuracyofcastspouredfromirreversiblehydrocolloidimpressionmaterials
AT waddelljohnneil influenceofundercutdepthsontheaccuracyofcastspouredfromirreversiblehydrocolloidimpressionmaterials