INTRODUCTION: Recanalization in an antegrade fashion in complex infrainguinal arterial disease can prove challenging and use of the Outback re-entry device via a retrograde approach may be an option. CASE PRESENTATION: Using an antegrade approach we were unable to cross the native occluded superfici...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6966385/ https://www.ncbi.nlm.nih.gov/pubmed/32026118 http://dx.doi.org/10.1186/s42155-019-0088-7 |
_version_ | 1783488721222369280 |
---|---|
author | Patrone, Lorenzo Stehno, Ondrej |
author_facet | Patrone, Lorenzo Stehno, Ondrej |
author_sort | Patrone, Lorenzo |
collection | PubMed |
description | INTRODUCTION: Recanalization in an antegrade fashion in complex infrainguinal arterial disease can prove challenging and use of the Outback re-entry device via a retrograde approach may be an option. CASE PRESENTATION: Using an antegrade approach we were unable to cross the native occluded superficial femoral artery in a patient after two occluded bypasses, with ulcers and was unfit for general anaesthesia. We successfully attempted retrograde re-entry using an Outback device via a phantom segment of the anterior tibial artery. After angioplasty and stenting a satisfactory result was achieved with one artery runoff. CONCLUSIONS: At the 24 months follow up reconstruction was patent and ulcers were healed after 4 months. The outcome of more cases will be decisive for the broader applicability of this technique. |
format | Online Article Text |
id | pubmed-6966385 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-69663852020-02-04 Retrograde insertion of the outback reentry device from a tibial artery for complex infrainguinal recanalization Patrone, Lorenzo Stehno, Ondrej CVIR Endovasc Case Report INTRODUCTION: Recanalization in an antegrade fashion in complex infrainguinal arterial disease can prove challenging and use of the Outback re-entry device via a retrograde approach may be an option. CASE PRESENTATION: Using an antegrade approach we were unable to cross the native occluded superficial femoral artery in a patient after two occluded bypasses, with ulcers and was unfit for general anaesthesia. We successfully attempted retrograde re-entry using an Outback device via a phantom segment of the anterior tibial artery. After angioplasty and stenting a satisfactory result was achieved with one artery runoff. CONCLUSIONS: At the 24 months follow up reconstruction was patent and ulcers were healed after 4 months. The outcome of more cases will be decisive for the broader applicability of this technique. Springer International Publishing 2019-12-30 /pmc/articles/PMC6966385/ /pubmed/32026118 http://dx.doi.org/10.1186/s42155-019-0088-7 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Case Report Patrone, Lorenzo Stehno, Ondrej Retrograde insertion of the outback reentry device from a tibial artery for complex infrainguinal recanalization |
title | Retrograde insertion of the outback reentry device from a tibial artery for complex infrainguinal recanalization |
title_full | Retrograde insertion of the outback reentry device from a tibial artery for complex infrainguinal recanalization |
title_fullStr | Retrograde insertion of the outback reentry device from a tibial artery for complex infrainguinal recanalization |
title_full_unstemmed | Retrograde insertion of the outback reentry device from a tibial artery for complex infrainguinal recanalization |
title_short | Retrograde insertion of the outback reentry device from a tibial artery for complex infrainguinal recanalization |
title_sort | retrograde insertion of the outback reentry device from a tibial artery for complex infrainguinal recanalization |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6966385/ https://www.ncbi.nlm.nih.gov/pubmed/32026118 http://dx.doi.org/10.1186/s42155-019-0088-7 |
work_keys_str_mv | AT patronelorenzo retrogradeinsertionoftheoutbackreentrydevicefromatibialarteryforcomplexinfrainguinalrecanalization AT stehnoondrej retrogradeinsertionoftheoutbackreentrydevicefromatibialarteryforcomplexinfrainguinalrecanalization |