Cargando…
Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis
Gait analysis is used widely in clinical practice to evaluate abnormal gait caused by disease. Conventionally, medical professionals use motion capture systems or make visual observations to evaluate a patient's gait. Recent biomedical engineering studies have proposed easy-to-use gait analysis...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6966410/ https://www.ncbi.nlm.nih.gov/pubmed/31998138 http://dx.doi.org/10.3389/fphys.2019.01530 |
_version_ | 1783488725469102080 |
---|---|
author | Hori, Koyu Mao, Yufeng Ono, Yumi Ora, Hiroki Hirobe, Yuki Sawada, Hiroyuki Inaba, Akira Orimo, Satoshi Miyake, Yoshihiro |
author_facet | Hori, Koyu Mao, Yufeng Ono, Yumi Ora, Hiroki Hirobe, Yuki Sawada, Hiroyuki Inaba, Akira Orimo, Satoshi Miyake, Yoshihiro |
author_sort | Hori, Koyu |
collection | PubMed |
description | Gait analysis is used widely in clinical practice to evaluate abnormal gait caused by disease. Conventionally, medical professionals use motion capture systems or make visual observations to evaluate a patient's gait. Recent biomedical engineering studies have proposed easy-to-use gait analysis methods employing wearable sensors with inertial measurement units (IMUs). IMUs placed on the shanks just above the ankles allow for long-term gait monitoring because the participant can walk with or without shoes during the analysis. To the knowledge of the authors, no IMU-based gait analysis method has been reported that estimates stride length, gait speed, stride duration, stance duration, and swing duration simultaneously. In the present study, we tested a proposed gait analysis method that uses IMUs attached on the shanks to estimate foot trajectory and temporal gait parameters. Our proposed method comprises two steps: stepwise dissociation of continuous gait data into multiple steps and three-dimensional trajectory estimation from data obtained from accelerometers and gyroscopes. We evaluated this proposed method by analyzing the gait of 19 able-bodied participants (mean age 23.9 years, 9 men and 10 women). Wearable sensors were attached on the participants' shanks, and we measured three-axis acceleration and three-axis angular velocity with the sensors to estimate foot trajectory during walking. We compared gait parameters estimated from the foot trajectory obtained with the proposed method and those measured with a motion capture system. Mean accuracy (± standard deviation) was 0.054 ± 0.031 m for stride length, 0.034 ± 0.039 m/s for gait speed, 0.002 ± 0.020 s for stride duration, 0.000 ± 0.017 s for stance duration, and 0.002 ± 0.024 s for swing duration. These results suggest that the proposed method is suitable for gait analysis, whereas there is a room for improvement of its accuracy and further development of this IMU-based gait analysis method will enable us to use such systems for clinical gait analysis. |
format | Online Article Text |
id | pubmed-6966410 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-69664102020-01-29 Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis Hori, Koyu Mao, Yufeng Ono, Yumi Ora, Hiroki Hirobe, Yuki Sawada, Hiroyuki Inaba, Akira Orimo, Satoshi Miyake, Yoshihiro Front Physiol Physiology Gait analysis is used widely in clinical practice to evaluate abnormal gait caused by disease. Conventionally, medical professionals use motion capture systems or make visual observations to evaluate a patient's gait. Recent biomedical engineering studies have proposed easy-to-use gait analysis methods employing wearable sensors with inertial measurement units (IMUs). IMUs placed on the shanks just above the ankles allow for long-term gait monitoring because the participant can walk with or without shoes during the analysis. To the knowledge of the authors, no IMU-based gait analysis method has been reported that estimates stride length, gait speed, stride duration, stance duration, and swing duration simultaneously. In the present study, we tested a proposed gait analysis method that uses IMUs attached on the shanks to estimate foot trajectory and temporal gait parameters. Our proposed method comprises two steps: stepwise dissociation of continuous gait data into multiple steps and three-dimensional trajectory estimation from data obtained from accelerometers and gyroscopes. We evaluated this proposed method by analyzing the gait of 19 able-bodied participants (mean age 23.9 years, 9 men and 10 women). Wearable sensors were attached on the participants' shanks, and we measured three-axis acceleration and three-axis angular velocity with the sensors to estimate foot trajectory during walking. We compared gait parameters estimated from the foot trajectory obtained with the proposed method and those measured with a motion capture system. Mean accuracy (± standard deviation) was 0.054 ± 0.031 m for stride length, 0.034 ± 0.039 m/s for gait speed, 0.002 ± 0.020 s for stride duration, 0.000 ± 0.017 s for stance duration, and 0.002 ± 0.024 s for swing duration. These results suggest that the proposed method is suitable for gait analysis, whereas there is a room for improvement of its accuracy and further development of this IMU-based gait analysis method will enable us to use such systems for clinical gait analysis. Frontiers Media S.A. 2020-01-10 /pmc/articles/PMC6966410/ /pubmed/31998138 http://dx.doi.org/10.3389/fphys.2019.01530 Text en Copyright © 2020 Hori, Mao, Ono, Ora, Hirobe, Sawada, Inaba, Orimo and Miyake. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Hori, Koyu Mao, Yufeng Ono, Yumi Ora, Hiroki Hirobe, Yuki Sawada, Hiroyuki Inaba, Akira Orimo, Satoshi Miyake, Yoshihiro Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis |
title | Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis |
title_full | Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis |
title_fullStr | Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis |
title_full_unstemmed | Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis |
title_short | Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis |
title_sort | inertial measurement unit-based estimation of foot trajectory for clinical gait analysis |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6966410/ https://www.ncbi.nlm.nih.gov/pubmed/31998138 http://dx.doi.org/10.3389/fphys.2019.01530 |
work_keys_str_mv | AT horikoyu inertialmeasurementunitbasedestimationoffoottrajectoryforclinicalgaitanalysis AT maoyufeng inertialmeasurementunitbasedestimationoffoottrajectoryforclinicalgaitanalysis AT onoyumi inertialmeasurementunitbasedestimationoffoottrajectoryforclinicalgaitanalysis AT orahiroki inertialmeasurementunitbasedestimationoffoottrajectoryforclinicalgaitanalysis AT hirobeyuki inertialmeasurementunitbasedestimationoffoottrajectoryforclinicalgaitanalysis AT sawadahiroyuki inertialmeasurementunitbasedestimationoffoottrajectoryforclinicalgaitanalysis AT inabaakira inertialmeasurementunitbasedestimationoffoottrajectoryforclinicalgaitanalysis AT orimosatoshi inertialmeasurementunitbasedestimationoffoottrajectoryforclinicalgaitanalysis AT miyakeyoshihiro inertialmeasurementunitbasedestimationoffoottrajectoryforclinicalgaitanalysis |