Cargando…

Technical approach and outcomes of failed infrarenal endovascular aneurysm repairs rescued with fenestrated and branched endografts

BACKGROUND: Endovascular rescue of failed infrarenal repair (EVAR) has emerged as an attractive option to stent graft explantation. The procedure, however, is underutilized due to limited devices accessibility and the challenges associated with their implantation in this patient population. The purp...

Descripción completa

Detalles Bibliográficos
Autores principales: Manunga, Jesse, Stanberry, Larissa I., Alden, Peter, Alexander, Jason, Skeik, Nedaa, Stephenson, Elliot, Titus, Jessica, Karam, Joseph, Teng, Xiaoyi, Sullivan, Timothy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6966416/
https://www.ncbi.nlm.nih.gov/pubmed/32026021
http://dx.doi.org/10.1186/s42155-019-0075-z
_version_ 1783488726604709888
author Manunga, Jesse
Stanberry, Larissa I.
Alden, Peter
Alexander, Jason
Skeik, Nedaa
Stephenson, Elliot
Titus, Jessica
Karam, Joseph
Teng, Xiaoyi
Sullivan, Timothy
author_facet Manunga, Jesse
Stanberry, Larissa I.
Alden, Peter
Alexander, Jason
Skeik, Nedaa
Stephenson, Elliot
Titus, Jessica
Karam, Joseph
Teng, Xiaoyi
Sullivan, Timothy
author_sort Manunga, Jesse
collection PubMed
description BACKGROUND: Endovascular rescue of failed infrarenal repair (EVAR) has emerged as an attractive option to stent graft explantation. The procedure, however, is underutilized due to limited devices accessibility and the challenges associated with their implantation in this patient population. The purpose of this study was to report our outcomes and discuss our approach to rescuing previously failed infrarenal endovascular aneurysm repairs (EVAR) with fenestrated/branched endografts (f/b-EVAR). METHODS: A retrospective analysis of prospectively collected data of consecutive patients with failed EVAR rescued with f/b-EVAR at our institution from November 2013 to March 2019 was conducted. The study primary end point was technical success; defined as the implantation of the device with no type I a/b or type III endoleak or conversion to open repair. Secondary endpoints included major adverse events (MAEs), graft patency and reintervention rates. RESULTS: During this time, 202 patients with complex aortic aneurysms were treated with f/b-EVAR. Of these, 19 patients (Male: 17, mean age 79 ± 7 years) underwent repair for failed EVAR. The median time from failed repair to f/b-EVAR was 48 (30, 60) months. Treatment failure was attributed to stent graft migration in 9 (47.4%) patients, disease progression in 5 (26.3%), short initial neck in 3 (15.8%) and unable to be determined in 2 (10.5%). Three patients were treated urgently with surgeon modified stent graft. Technical success was achieved in 18 patients (95%), including two who had undergone emergent repair for rupture. Seventy-two targeted vessels (97.3%) were successfully incorporated. Sixteen (84.2%) patients required a thoracoabdominal repair to achieve a durable seal. Major adverse events (MAEs) occurred in 3 patients (15.7%) including paralysis and death in one (5.3%), compartment syndrome and temporary dialysis in another and laparotomy with snorkeling of one renal and bypass of the other in the third patient. Median (IQR) hospital length of stay was 3 (2, 4) days. Late reintervention, primary target vessel patency and primary assisted patency rates were 5.3%, 98.6% and 100%, respectively. CONCLUSION: Implantation of f/b-EVAR in patients with failed previous EVAR is a challenging undertaking that can be performed safely with a high technical success and low reintervention rates.
format Online
Article
Text
id pubmed-6966416
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-69664162020-02-04 Technical approach and outcomes of failed infrarenal endovascular aneurysm repairs rescued with fenestrated and branched endografts Manunga, Jesse Stanberry, Larissa I. Alden, Peter Alexander, Jason Skeik, Nedaa Stephenson, Elliot Titus, Jessica Karam, Joseph Teng, Xiaoyi Sullivan, Timothy CVIR Endovasc Original Article BACKGROUND: Endovascular rescue of failed infrarenal repair (EVAR) has emerged as an attractive option to stent graft explantation. The procedure, however, is underutilized due to limited devices accessibility and the challenges associated with their implantation in this patient population. The purpose of this study was to report our outcomes and discuss our approach to rescuing previously failed infrarenal endovascular aneurysm repairs (EVAR) with fenestrated/branched endografts (f/b-EVAR). METHODS: A retrospective analysis of prospectively collected data of consecutive patients with failed EVAR rescued with f/b-EVAR at our institution from November 2013 to March 2019 was conducted. The study primary end point was technical success; defined as the implantation of the device with no type I a/b or type III endoleak or conversion to open repair. Secondary endpoints included major adverse events (MAEs), graft patency and reintervention rates. RESULTS: During this time, 202 patients with complex aortic aneurysms were treated with f/b-EVAR. Of these, 19 patients (Male: 17, mean age 79 ± 7 years) underwent repair for failed EVAR. The median time from failed repair to f/b-EVAR was 48 (30, 60) months. Treatment failure was attributed to stent graft migration in 9 (47.4%) patients, disease progression in 5 (26.3%), short initial neck in 3 (15.8%) and unable to be determined in 2 (10.5%). Three patients were treated urgently with surgeon modified stent graft. Technical success was achieved in 18 patients (95%), including two who had undergone emergent repair for rupture. Seventy-two targeted vessels (97.3%) were successfully incorporated. Sixteen (84.2%) patients required a thoracoabdominal repair to achieve a durable seal. Major adverse events (MAEs) occurred in 3 patients (15.7%) including paralysis and death in one (5.3%), compartment syndrome and temporary dialysis in another and laparotomy with snorkeling of one renal and bypass of the other in the third patient. Median (IQR) hospital length of stay was 3 (2, 4) days. Late reintervention, primary target vessel patency and primary assisted patency rates were 5.3%, 98.6% and 100%, respectively. CONCLUSION: Implantation of f/b-EVAR in patients with failed previous EVAR is a challenging undertaking that can be performed safely with a high technical success and low reintervention rates. Springer International Publishing 2019-10-27 /pmc/articles/PMC6966416/ /pubmed/32026021 http://dx.doi.org/10.1186/s42155-019-0075-z Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Manunga, Jesse
Stanberry, Larissa I.
Alden, Peter
Alexander, Jason
Skeik, Nedaa
Stephenson, Elliot
Titus, Jessica
Karam, Joseph
Teng, Xiaoyi
Sullivan, Timothy
Technical approach and outcomes of failed infrarenal endovascular aneurysm repairs rescued with fenestrated and branched endografts
title Technical approach and outcomes of failed infrarenal endovascular aneurysm repairs rescued with fenestrated and branched endografts
title_full Technical approach and outcomes of failed infrarenal endovascular aneurysm repairs rescued with fenestrated and branched endografts
title_fullStr Technical approach and outcomes of failed infrarenal endovascular aneurysm repairs rescued with fenestrated and branched endografts
title_full_unstemmed Technical approach and outcomes of failed infrarenal endovascular aneurysm repairs rescued with fenestrated and branched endografts
title_short Technical approach and outcomes of failed infrarenal endovascular aneurysm repairs rescued with fenestrated and branched endografts
title_sort technical approach and outcomes of failed infrarenal endovascular aneurysm repairs rescued with fenestrated and branched endografts
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6966416/
https://www.ncbi.nlm.nih.gov/pubmed/32026021
http://dx.doi.org/10.1186/s42155-019-0075-z
work_keys_str_mv AT manungajesse technicalapproachandoutcomesoffailedinfrarenalendovascularaneurysmrepairsrescuedwithfenestratedandbranchedendografts
AT stanberrylarissai technicalapproachandoutcomesoffailedinfrarenalendovascularaneurysmrepairsrescuedwithfenestratedandbranchedendografts
AT aldenpeter technicalapproachandoutcomesoffailedinfrarenalendovascularaneurysmrepairsrescuedwithfenestratedandbranchedendografts
AT alexanderjason technicalapproachandoutcomesoffailedinfrarenalendovascularaneurysmrepairsrescuedwithfenestratedandbranchedendografts
AT skeiknedaa technicalapproachandoutcomesoffailedinfrarenalendovascularaneurysmrepairsrescuedwithfenestratedandbranchedendografts
AT stephensonelliot technicalapproachandoutcomesoffailedinfrarenalendovascularaneurysmrepairsrescuedwithfenestratedandbranchedendografts
AT titusjessica technicalapproachandoutcomesoffailedinfrarenalendovascularaneurysmrepairsrescuedwithfenestratedandbranchedendografts
AT karamjoseph technicalapproachandoutcomesoffailedinfrarenalendovascularaneurysmrepairsrescuedwithfenestratedandbranchedendografts
AT tengxiaoyi technicalapproachandoutcomesoffailedinfrarenalendovascularaneurysmrepairsrescuedwithfenestratedandbranchedendografts
AT sullivantimothy technicalapproachandoutcomesoffailedinfrarenalendovascularaneurysmrepairsrescuedwithfenestratedandbranchedendografts