Cargando…

Non-invasive assessment of vibration perception and protective sensation in people with diabetes mellitus: inter- and intra-rater reliability

BACKGROUND: Testing of protective sensation and vibration perception are two of the most commonly used non-invasive methods of screening for diabetes-related peripheral neuropathy (DPN). However, there is limited research investigating the reliability of these tests in people with diabetes. The aim...

Descripción completa

Detalles Bibliográficos
Autores principales: Lanting, Sean Michael, Spink, Martin Jeremy, Tehan, Peta Ellen, Vickers, Stephanie, Casey, Sarah Louise, Chuter, Vivienne Helaine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6966840/
https://www.ncbi.nlm.nih.gov/pubmed/31988664
http://dx.doi.org/10.1186/s13047-020-0371-9
_version_ 1783488827964260352
author Lanting, Sean Michael
Spink, Martin Jeremy
Tehan, Peta Ellen
Vickers, Stephanie
Casey, Sarah Louise
Chuter, Vivienne Helaine
author_facet Lanting, Sean Michael
Spink, Martin Jeremy
Tehan, Peta Ellen
Vickers, Stephanie
Casey, Sarah Louise
Chuter, Vivienne Helaine
author_sort Lanting, Sean Michael
collection PubMed
description BACKGROUND: Testing of protective sensation and vibration perception are two of the most commonly used non-invasive methods of screening for diabetes-related peripheral neuropathy (DPN). However, there is limited research investigating the reliability of these tests in people with diabetes. The aim of this study was to determine the inter- and intra-rater reliability of methods used to test vibration perception and protective sensation in a community-based population of adults with type 2 diabetes. METHODS: Three podiatrists with varying clinical experience tested four- and 10-site, 10 g monofilament and vibration perception threshold (VPT). In a separate cohort, the reliability of a graduated tuning fork as well as two methods of conventional tuning fork (on/off method and dampening method) was undertaken by a new graduate podiatrist and podiatrist with one-year’s clinical experience. The intra- (Cohen’s К) and inter-rater (Cohen’s or Fleiss’ К) reliability of each test was determined. RESULTS: Fifty participants (66% male, 100% type 2, 32% with DPN) underwent monofilament and neurothesiometer testing with 44 returning for the retest. Twenty-four participants (63% male, 100% type 2, 4% with DPN) underwent tuning fork testing and returned for retest. All tests demonstrated acceptable inter-rater reliability ranging from moderate (10-site monofilament, К: 0.54, CI: 0.38–0.70, p = 0.02) to substantial (graduated tuning fork, К: 0.68, CI: 0.41–0.95, p < 0.01). The 10-site monofilament (К: 0.44–0.77) outperformed the 4-site test (К: 0.34–0.67) and the dampened tuning fork method (К: 0.41–0.49) showed lower intra-rater reliability compared to both conventional (К: 0.52–0.57) and graduated methods (К: 0.50–0.57). CONCLUSION: We support the current recommendations of using more than one test to screen and monitor progression of DPN. Four- and 10-site 10 g monofilament testing have similarly acceptable levels of reliability and the neurothesiometer is the most reliable method of assessing vibration perception function. Use of a graduated tuning fork was slightly more reliable than other methods of tuning fork application however all had substantial reliability. Years of clinical experience only marginally affected test reliability overall and due to subjective nature of the tests we suggest that testing should be performed regularly and repetitively.
format Online
Article
Text
id pubmed-6966840
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-69668402020-01-27 Non-invasive assessment of vibration perception and protective sensation in people with diabetes mellitus: inter- and intra-rater reliability Lanting, Sean Michael Spink, Martin Jeremy Tehan, Peta Ellen Vickers, Stephanie Casey, Sarah Louise Chuter, Vivienne Helaine J Foot Ankle Res Research BACKGROUND: Testing of protective sensation and vibration perception are two of the most commonly used non-invasive methods of screening for diabetes-related peripheral neuropathy (DPN). However, there is limited research investigating the reliability of these tests in people with diabetes. The aim of this study was to determine the inter- and intra-rater reliability of methods used to test vibration perception and protective sensation in a community-based population of adults with type 2 diabetes. METHODS: Three podiatrists with varying clinical experience tested four- and 10-site, 10 g monofilament and vibration perception threshold (VPT). In a separate cohort, the reliability of a graduated tuning fork as well as two methods of conventional tuning fork (on/off method and dampening method) was undertaken by a new graduate podiatrist and podiatrist with one-year’s clinical experience. The intra- (Cohen’s К) and inter-rater (Cohen’s or Fleiss’ К) reliability of each test was determined. RESULTS: Fifty participants (66% male, 100% type 2, 32% with DPN) underwent monofilament and neurothesiometer testing with 44 returning for the retest. Twenty-four participants (63% male, 100% type 2, 4% with DPN) underwent tuning fork testing and returned for retest. All tests demonstrated acceptable inter-rater reliability ranging from moderate (10-site monofilament, К: 0.54, CI: 0.38–0.70, p = 0.02) to substantial (graduated tuning fork, К: 0.68, CI: 0.41–0.95, p < 0.01). The 10-site monofilament (К: 0.44–0.77) outperformed the 4-site test (К: 0.34–0.67) and the dampened tuning fork method (К: 0.41–0.49) showed lower intra-rater reliability compared to both conventional (К: 0.52–0.57) and graduated methods (К: 0.50–0.57). CONCLUSION: We support the current recommendations of using more than one test to screen and monitor progression of DPN. Four- and 10-site 10 g monofilament testing have similarly acceptable levels of reliability and the neurothesiometer is the most reliable method of assessing vibration perception function. Use of a graduated tuning fork was slightly more reliable than other methods of tuning fork application however all had substantial reliability. Years of clinical experience only marginally affected test reliability overall and due to subjective nature of the tests we suggest that testing should be performed regularly and repetitively. BioMed Central 2020-01-16 /pmc/articles/PMC6966840/ /pubmed/31988664 http://dx.doi.org/10.1186/s13047-020-0371-9 Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Lanting, Sean Michael
Spink, Martin Jeremy
Tehan, Peta Ellen
Vickers, Stephanie
Casey, Sarah Louise
Chuter, Vivienne Helaine
Non-invasive assessment of vibration perception and protective sensation in people with diabetes mellitus: inter- and intra-rater reliability
title Non-invasive assessment of vibration perception and protective sensation in people with diabetes mellitus: inter- and intra-rater reliability
title_full Non-invasive assessment of vibration perception and protective sensation in people with diabetes mellitus: inter- and intra-rater reliability
title_fullStr Non-invasive assessment of vibration perception and protective sensation in people with diabetes mellitus: inter- and intra-rater reliability
title_full_unstemmed Non-invasive assessment of vibration perception and protective sensation in people with diabetes mellitus: inter- and intra-rater reliability
title_short Non-invasive assessment of vibration perception and protective sensation in people with diabetes mellitus: inter- and intra-rater reliability
title_sort non-invasive assessment of vibration perception and protective sensation in people with diabetes mellitus: inter- and intra-rater reliability
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6966840/
https://www.ncbi.nlm.nih.gov/pubmed/31988664
http://dx.doi.org/10.1186/s13047-020-0371-9
work_keys_str_mv AT lantingseanmichael noninvasiveassessmentofvibrationperceptionandprotectivesensationinpeoplewithdiabetesmellitusinterandintraraterreliability
AT spinkmartinjeremy noninvasiveassessmentofvibrationperceptionandprotectivesensationinpeoplewithdiabetesmellitusinterandintraraterreliability
AT tehanpetaellen noninvasiveassessmentofvibrationperceptionandprotectivesensationinpeoplewithdiabetesmellitusinterandintraraterreliability
AT vickersstephanie noninvasiveassessmentofvibrationperceptionandprotectivesensationinpeoplewithdiabetesmellitusinterandintraraterreliability
AT caseysarahlouise noninvasiveassessmentofvibrationperceptionandprotectivesensationinpeoplewithdiabetesmellitusinterandintraraterreliability
AT chuterviviennehelaine noninvasiveassessmentofvibrationperceptionandprotectivesensationinpeoplewithdiabetesmellitusinterandintraraterreliability