Cargando…
A Set of Time-and-Frequency-Localized Short-Duration Speech-Like Stimuli for Assessing Hearing-Aid Performance via Cortical Auditory-Evoked Potentials
Short-duration speech-like stimuli, for example, excised from running speech, can be used in the clinical setting to assess the integrity of the human auditory pathway at the level of the cortex. Modeling of the cochlear response to these stimuli demonstrated an imprecision in the location of the sp...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6967206/ https://www.ncbi.nlm.nih.gov/pubmed/31858885 http://dx.doi.org/10.1177/2331216519885568 |
_version_ | 1783488904738897920 |
---|---|
author | Stone, Michael A. Visram, Anisa Harte, James M. Munro, Kevin J. |
author_facet | Stone, Michael A. Visram, Anisa Harte, James M. Munro, Kevin J. |
author_sort | Stone, Michael A. |
collection | PubMed |
description | Short-duration speech-like stimuli, for example, excised from running speech, can be used in the clinical setting to assess the integrity of the human auditory pathway at the level of the cortex. Modeling of the cochlear response to these stimuli demonstrated an imprecision in the location of the spectrotemporal energy, giving rise to uncertainty as to what and when of a stimulus caused any evoked electrophysiological response. This article reports the development and assessment of four short-duration, limited-bandwidth stimuli centered at low, mid, mid-high, and high frequencies, suitable for free-field delivery and, in addition, reproduction via hearing aids. The durations were determined by the British Society of Audiology recommended procedure for measuring Cortical Auditory-Evoked Potentials. The levels and bandwidths were chosen via a computational model to produce uniform cochlear excitation over a width exceeding that likely in a worst-case hearing-impaired listener. These parameters produce robustness against errors in insertion gains, and variation in frequency responses, due to transducer imperfections, room modes, and age-related variation in meatal resonances. The parameter choice predicts large spectral separation between adjacent stimuli on the cochlea. Analysis of the signals processed by examples of recent digital hearing aids mostly show similar levels of gain applied to each stimulus, independent of whether the stimulus was presented in isolation, bursts, continuous, or embedded in continuous speech. These stimuli seem to be suitable for measuring hearing-aided Cortical Auditory-Evoked Potentials and have the potential to be of benefit in the clinical setting. |
format | Online Article Text |
id | pubmed-6967206 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-69672062020-01-31 A Set of Time-and-Frequency-Localized Short-Duration Speech-Like Stimuli for Assessing Hearing-Aid Performance via Cortical Auditory-Evoked Potentials Stone, Michael A. Visram, Anisa Harte, James M. Munro, Kevin J. Trends Hear ManCAD100 Short-duration speech-like stimuli, for example, excised from running speech, can be used in the clinical setting to assess the integrity of the human auditory pathway at the level of the cortex. Modeling of the cochlear response to these stimuli demonstrated an imprecision in the location of the spectrotemporal energy, giving rise to uncertainty as to what and when of a stimulus caused any evoked electrophysiological response. This article reports the development and assessment of four short-duration, limited-bandwidth stimuli centered at low, mid, mid-high, and high frequencies, suitable for free-field delivery and, in addition, reproduction via hearing aids. The durations were determined by the British Society of Audiology recommended procedure for measuring Cortical Auditory-Evoked Potentials. The levels and bandwidths were chosen via a computational model to produce uniform cochlear excitation over a width exceeding that likely in a worst-case hearing-impaired listener. These parameters produce robustness against errors in insertion gains, and variation in frequency responses, due to transducer imperfections, room modes, and age-related variation in meatal resonances. The parameter choice predicts large spectral separation between adjacent stimuli on the cochlea. Analysis of the signals processed by examples of recent digital hearing aids mostly show similar levels of gain applied to each stimulus, independent of whether the stimulus was presented in isolation, bursts, continuous, or embedded in continuous speech. These stimuli seem to be suitable for measuring hearing-aided Cortical Auditory-Evoked Potentials and have the potential to be of benefit in the clinical setting. SAGE Publications 2019-12-20 /pmc/articles/PMC6967206/ /pubmed/31858885 http://dx.doi.org/10.1177/2331216519885568 Text en © The Author(s) 2019 http://www.creativecommons.org/licenses/by/4.0/ Creative Commons CC-BY: This article is distributed under the terms of the Creative Commons Attribution 4.0 License (http://www.creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | ManCAD100 Stone, Michael A. Visram, Anisa Harte, James M. Munro, Kevin J. A Set of Time-and-Frequency-Localized Short-Duration Speech-Like Stimuli for Assessing Hearing-Aid Performance via Cortical Auditory-Evoked Potentials |
title | A Set of Time-and-Frequency-Localized Short-Duration Speech-Like
Stimuli for Assessing Hearing-Aid Performance via Cortical Auditory-Evoked
Potentials |
title_full | A Set of Time-and-Frequency-Localized Short-Duration Speech-Like
Stimuli for Assessing Hearing-Aid Performance via Cortical Auditory-Evoked
Potentials |
title_fullStr | A Set of Time-and-Frequency-Localized Short-Duration Speech-Like
Stimuli for Assessing Hearing-Aid Performance via Cortical Auditory-Evoked
Potentials |
title_full_unstemmed | A Set of Time-and-Frequency-Localized Short-Duration Speech-Like
Stimuli for Assessing Hearing-Aid Performance via Cortical Auditory-Evoked
Potentials |
title_short | A Set of Time-and-Frequency-Localized Short-Duration Speech-Like
Stimuli for Assessing Hearing-Aid Performance via Cortical Auditory-Evoked
Potentials |
title_sort | set of time-and-frequency-localized short-duration speech-like
stimuli for assessing hearing-aid performance via cortical auditory-evoked
potentials |
topic | ManCAD100 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6967206/ https://www.ncbi.nlm.nih.gov/pubmed/31858885 http://dx.doi.org/10.1177/2331216519885568 |
work_keys_str_mv | AT stonemichaela asetoftimeandfrequencylocalizedshortdurationspeechlikestimuliforassessinghearingaidperformanceviacorticalauditoryevokedpotentials AT visramanisa asetoftimeandfrequencylocalizedshortdurationspeechlikestimuliforassessinghearingaidperformanceviacorticalauditoryevokedpotentials AT hartejamesm asetoftimeandfrequencylocalizedshortdurationspeechlikestimuliforassessinghearingaidperformanceviacorticalauditoryevokedpotentials AT munrokevinj asetoftimeandfrequencylocalizedshortdurationspeechlikestimuliforassessinghearingaidperformanceviacorticalauditoryevokedpotentials AT stonemichaela setoftimeandfrequencylocalizedshortdurationspeechlikestimuliforassessinghearingaidperformanceviacorticalauditoryevokedpotentials AT visramanisa setoftimeandfrequencylocalizedshortdurationspeechlikestimuliforassessinghearingaidperformanceviacorticalauditoryevokedpotentials AT hartejamesm setoftimeandfrequencylocalizedshortdurationspeechlikestimuliforassessinghearingaidperformanceviacorticalauditoryevokedpotentials AT munrokevinj setoftimeandfrequencylocalizedshortdurationspeechlikestimuliforassessinghearingaidperformanceviacorticalauditoryevokedpotentials |