Cargando…
Severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement
BACKGROUND: Severe mitral regurgitation (MR) after aortic valve replacement (AVR) is a serious complication. Although several causes of MR after AVR have been reported, severe MR due to geometric changes in the mitral valve imposed by an aortic valve prosthesis has not been reported. We here report...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6967239/ https://www.ncbi.nlm.nih.gov/pubmed/32025917 http://dx.doi.org/10.1186/s40981-019-0277-3 |
_version_ | 1783488912364142592 |
---|---|
author | Wakabayashi, Ryo Ide, Susumu Ishida, Takashi Tanaka, Satoshi Kawamata, Mikito |
author_facet | Wakabayashi, Ryo Ide, Susumu Ishida, Takashi Tanaka, Satoshi Kawamata, Mikito |
author_sort | Wakabayashi, Ryo |
collection | PubMed |
description | BACKGROUND: Severe mitral regurgitation (MR) after aortic valve replacement (AVR) is a serious complication. Although several causes of MR after AVR have been reported, severe MR due to geometric changes in the mitral valve imposed by an aortic valve prosthesis has not been reported. We here report a case of severe MR after AVR that was improved after re-AVR. CASE PRESENTATION: A 77-year-old male underwent elective total aortic arch replacement and AVR. Mild MR was preoperatively identified. After surgery and separation from cardiopulmonary bypass, transesophageal echocardiography (TEE) demonstrated restriction and distortion of the anterior mitral leaflet and severe MR. Displacement of the anterior mitral annulus by the prosthetic aortic valve was strongly suspected to be the cause of MR, which should be surgically restored. Re-AVR using a small-sized valve was then performed. Consequently, the structural changes in the mitral valve were reverted and the MR was reduced. CONCLUSIONS: Geometric changes in the mitral valve induced by an aortic valve prosthesis can cause massive increment of MR. Intraoperative TEE examination of the mitral apparatus is important when severe MR occurs after AVR. |
format | Online Article Text |
id | pubmed-6967239 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-69672392020-02-04 Severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement Wakabayashi, Ryo Ide, Susumu Ishida, Takashi Tanaka, Satoshi Kawamata, Mikito JA Clin Rep Case Report BACKGROUND: Severe mitral regurgitation (MR) after aortic valve replacement (AVR) is a serious complication. Although several causes of MR after AVR have been reported, severe MR due to geometric changes in the mitral valve imposed by an aortic valve prosthesis has not been reported. We here report a case of severe MR after AVR that was improved after re-AVR. CASE PRESENTATION: A 77-year-old male underwent elective total aortic arch replacement and AVR. Mild MR was preoperatively identified. After surgery and separation from cardiopulmonary bypass, transesophageal echocardiography (TEE) demonstrated restriction and distortion of the anterior mitral leaflet and severe MR. Displacement of the anterior mitral annulus by the prosthetic aortic valve was strongly suspected to be the cause of MR, which should be surgically restored. Re-AVR using a small-sized valve was then performed. Consequently, the structural changes in the mitral valve were reverted and the MR was reduced. CONCLUSIONS: Geometric changes in the mitral valve induced by an aortic valve prosthesis can cause massive increment of MR. Intraoperative TEE examination of the mitral apparatus is important when severe MR occurs after AVR. Springer Berlin Heidelberg 2019-09-05 /pmc/articles/PMC6967239/ /pubmed/32025917 http://dx.doi.org/10.1186/s40981-019-0277-3 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Case Report Wakabayashi, Ryo Ide, Susumu Ishida, Takashi Tanaka, Satoshi Kawamata, Mikito Severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement |
title | Severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement |
title_full | Severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement |
title_fullStr | Severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement |
title_full_unstemmed | Severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement |
title_short | Severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement |
title_sort | severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6967239/ https://www.ncbi.nlm.nih.gov/pubmed/32025917 http://dx.doi.org/10.1186/s40981-019-0277-3 |
work_keys_str_mv | AT wakabayashiryo severemitralregurgitationduetogeometricchangesinthemitralvalveaftersurgicalaorticvalvereplacement AT idesusumu severemitralregurgitationduetogeometricchangesinthemitralvalveaftersurgicalaorticvalvereplacement AT ishidatakashi severemitralregurgitationduetogeometricchangesinthemitralvalveaftersurgicalaorticvalvereplacement AT tanakasatoshi severemitralregurgitationduetogeometricchangesinthemitralvalveaftersurgicalaorticvalvereplacement AT kawamatamikito severemitralregurgitationduetogeometricchangesinthemitralvalveaftersurgicalaorticvalvereplacement |