Cargando…

Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma

PURPOSE: To evaluate the role of contrast-enhanced ultrasound (CEUS) in differentiating bland thrombus from tumor thrombus of the inferior vena cava (IVC) in patients with renal cell carcinoma (RCC). MATERIALS AND METHODS: We retrospectively investigated 30 consecutive patients who underwent robot-a...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Qiuyang, Wang, Zhongxin, Ma, Xin, Tang, Jie, Luo, Yukun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Urologia 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6968914/
https://www.ncbi.nlm.nih.gov/pubmed/31851465
http://dx.doi.org/10.1590/S1677-5538.IBJU.2019.0304
_version_ 1783489230588084224
author Li, Qiuyang
Wang, Zhongxin
Ma, Xin
Tang, Jie
Luo, Yukun
author_facet Li, Qiuyang
Wang, Zhongxin
Ma, Xin
Tang, Jie
Luo, Yukun
author_sort Li, Qiuyang
collection PubMed
description PURPOSE: To evaluate the role of contrast-enhanced ultrasound (CEUS) in differentiating bland thrombus from tumor thrombus of the inferior vena cava (IVC) in patients with renal cell carcinoma (RCC). MATERIALS AND METHODS: We retrospectively investigated 30 consecutive patients who underwent robot-assisted radical nephrectomy with IVC thrombectomy and had pathologically confirmed RCC. All patients underwent US and CEUS examination. Two off-line readers observed and recorded thrombus imaging information and enhancement patterns. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value for bland thrombus were assessed. RESULTS: Of the 30 patients, no adverse events occurred during administration of the contrast agent. Early enhancement of the mass within the IVC lumen on CEUS was an indicator of tumor thrombus. Bland thrombus showed no intraluminal flow on CEUS. There were eight (26.7%) patients with bland thrombus, including three level II, two level III, and three level IV. There were three cases with cephalic bland thrombus and five cases with caudal bland thrombus. Three caudal bland thrombi extended to the iliac vein and underwent surgical IVC interruption. Based on no intraluminal flow, for bland thrombus, CEUS had 87.5% sensitivity, 100% specificity, 96.7% accuracy, 100% positive predictive value and 95.6% negative predictive value. CONCLUSION: Our study demonstrates the potential of CEUS in the differentiation of bland and tumor thrombus of the IVC in patients with RCC. Since CEUS is an effective, inexpensive, and non-invasive method, it could be a reliable tool in the evaluation of IVC thrombus in patients with RCC.
format Online
Article
Text
id pubmed-6968914
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Sociedade Brasileira de Urologia
record_format MEDLINE/PubMed
spelling pubmed-69689142020-08-03 Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma Li, Qiuyang Wang, Zhongxin Ma, Xin Tang, Jie Luo, Yukun Int Braz J Urol Original Article PURPOSE: To evaluate the role of contrast-enhanced ultrasound (CEUS) in differentiating bland thrombus from tumor thrombus of the inferior vena cava (IVC) in patients with renal cell carcinoma (RCC). MATERIALS AND METHODS: We retrospectively investigated 30 consecutive patients who underwent robot-assisted radical nephrectomy with IVC thrombectomy and had pathologically confirmed RCC. All patients underwent US and CEUS examination. Two off-line readers observed and recorded thrombus imaging information and enhancement patterns. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value for bland thrombus were assessed. RESULTS: Of the 30 patients, no adverse events occurred during administration of the contrast agent. Early enhancement of the mass within the IVC lumen on CEUS was an indicator of tumor thrombus. Bland thrombus showed no intraluminal flow on CEUS. There were eight (26.7%) patients with bland thrombus, including three level II, two level III, and three level IV. There were three cases with cephalic bland thrombus and five cases with caudal bland thrombus. Three caudal bland thrombi extended to the iliac vein and underwent surgical IVC interruption. Based on no intraluminal flow, for bland thrombus, CEUS had 87.5% sensitivity, 100% specificity, 96.7% accuracy, 100% positive predictive value and 95.6% negative predictive value. CONCLUSION: Our study demonstrates the potential of CEUS in the differentiation of bland and tumor thrombus of the IVC in patients with RCC. Since CEUS is an effective, inexpensive, and non-invasive method, it could be a reliable tool in the evaluation of IVC thrombus in patients with RCC. Sociedade Brasileira de Urologia 2020-01-13 /pmc/articles/PMC6968914/ /pubmed/31851465 http://dx.doi.org/10.1590/S1677-5538.IBJU.2019.0304 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Li, Qiuyang
Wang, Zhongxin
Ma, Xin
Tang, Jie
Luo, Yukun
Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title_full Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title_fullStr Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title_full_unstemmed Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title_short Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
title_sort diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6968914/
https://www.ncbi.nlm.nih.gov/pubmed/31851465
http://dx.doi.org/10.1590/S1677-5538.IBJU.2019.0304
work_keys_str_mv AT liqiuyang diagnosticaccuracyofcontrastenhancedultrasoundfordetectingblandthrombusfrominferiorvenacavatumorthrombusinpatientswithrenalcellcarcinoma
AT wangzhongxin diagnosticaccuracyofcontrastenhancedultrasoundfordetectingblandthrombusfrominferiorvenacavatumorthrombusinpatientswithrenalcellcarcinoma
AT maxin diagnosticaccuracyofcontrastenhancedultrasoundfordetectingblandthrombusfrominferiorvenacavatumorthrombusinpatientswithrenalcellcarcinoma
AT tangjie diagnosticaccuracyofcontrastenhancedultrasoundfordetectingblandthrombusfrominferiorvenacavatumorthrombusinpatientswithrenalcellcarcinoma
AT luoyukun diagnosticaccuracyofcontrastenhancedultrasoundfordetectingblandthrombusfrominferiorvenacavatumorthrombusinpatientswithrenalcellcarcinoma