Cargando…

Analysis of clinical effect and radiographic outcomes of Isobar TTL system for two-segment lumbar degenerative disease: a retrospective study

BACKGROUND: Nonfusion fixation is an effective way to treat lumbar degeneration. In the present study, we analyzed the clinical effects and radiographic outcomes of the Isobar TTL system used to treat two-segment lumbar degenerative disease. METHOD: Forty-one patients diagnosed with two-segment lumb...

Descripción completa

Detalles Bibliográficos
Autores principales: Ji, Zhi-Sheng, Yang, Hua, Yang, Yu-Hao, Li, Shao-Jin, Luo, Jian-Xian, Zhang, Guo-Wei, Lin, Hong-Sheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6969481/
https://www.ncbi.nlm.nih.gov/pubmed/31952499
http://dx.doi.org/10.1186/s12893-020-0680-8
_version_ 1783489339345338368
author Ji, Zhi-Sheng
Yang, Hua
Yang, Yu-Hao
Li, Shao-Jin
Luo, Jian-Xian
Zhang, Guo-Wei
Lin, Hong-Sheng
author_facet Ji, Zhi-Sheng
Yang, Hua
Yang, Yu-Hao
Li, Shao-Jin
Luo, Jian-Xian
Zhang, Guo-Wei
Lin, Hong-Sheng
author_sort Ji, Zhi-Sheng
collection PubMed
description BACKGROUND: Nonfusion fixation is an effective way to treat lumbar degeneration. In the present study, we analyzed the clinical effects and radiographic outcomes of the Isobar TTL system used to treat two-segment lumbar degenerative disease. METHOD: Forty-one patients diagnosed with two-segment lumbar degenerative disease underwent surgical implantation of the Isobar TTL dynamic stabilization system (n = 20) or a rigid system (n = 21) from January 2013 to June 2017. The mean follow-up time was 23.6 (range 15–37) months. Clinical results were evaluated with the Oswestry Disability Index (ODI), modified Macnab criteria, and the visual analog score (VAS). Radiographic evaluations included the height of the intervertebral space and the range of motion (ROM) of the treated and adjacent segments. The intervertebral disc signal was classified using the modified Pfirrmann grading system and the University of California at Los Angeles (UCLA) system. RESULTS: The clinical results, including the ODI and VAS, showed that there was significant improvement in the two groups after implantation and that the difference between the two groups was not significant. In addition, the clinical efficacy indicated by the modified Macnab criteria for the two groups was similar. Radiological outcomes included the height of the intervertebral space, lumbar mobility, and intervertebral disc signal. The height of the intervertebral space of the upper adjacent segment L2/3 in the rigid group was significantly lower than that in the Isobar TTL group at the last follow-up. Furthermore, the number of ROMs of the fixed-segment L3/4 in the Isobar TTL group was significantly less than that before implantation, suggesting that the fixed-segment ROMs in the Isobar TTL group were limited. In addition, the ROM of the upper adjacent segment L2/3 in the last follow-up of the rigid group increased significantly, while that of the Isobar TTL group did not change after implantation. Finally, the incidence of adjacent-segment degeneration (ASD) was significantly greater in the rigid group than in the Isobar TTL group according to the UCLA system. CONCLUSION: The Isobar TTL system can be clinically effective for treating two-segment lumbar degenerative disease. Compared with rigid fixation, the Isobar TTL system yielded better radiographic outcomes and maintained the mobility of the treated segments with less impact on the proximal adjacent segment.
format Online
Article
Text
id pubmed-6969481
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-69694812020-01-27 Analysis of clinical effect and radiographic outcomes of Isobar TTL system for two-segment lumbar degenerative disease: a retrospective study Ji, Zhi-Sheng Yang, Hua Yang, Yu-Hao Li, Shao-Jin Luo, Jian-Xian Zhang, Guo-Wei Lin, Hong-Sheng BMC Surg Research Article BACKGROUND: Nonfusion fixation is an effective way to treat lumbar degeneration. In the present study, we analyzed the clinical effects and radiographic outcomes of the Isobar TTL system used to treat two-segment lumbar degenerative disease. METHOD: Forty-one patients diagnosed with two-segment lumbar degenerative disease underwent surgical implantation of the Isobar TTL dynamic stabilization system (n = 20) or a rigid system (n = 21) from January 2013 to June 2017. The mean follow-up time was 23.6 (range 15–37) months. Clinical results were evaluated with the Oswestry Disability Index (ODI), modified Macnab criteria, and the visual analog score (VAS). Radiographic evaluations included the height of the intervertebral space and the range of motion (ROM) of the treated and adjacent segments. The intervertebral disc signal was classified using the modified Pfirrmann grading system and the University of California at Los Angeles (UCLA) system. RESULTS: The clinical results, including the ODI and VAS, showed that there was significant improvement in the two groups after implantation and that the difference between the two groups was not significant. In addition, the clinical efficacy indicated by the modified Macnab criteria for the two groups was similar. Radiological outcomes included the height of the intervertebral space, lumbar mobility, and intervertebral disc signal. The height of the intervertebral space of the upper adjacent segment L2/3 in the rigid group was significantly lower than that in the Isobar TTL group at the last follow-up. Furthermore, the number of ROMs of the fixed-segment L3/4 in the Isobar TTL group was significantly less than that before implantation, suggesting that the fixed-segment ROMs in the Isobar TTL group were limited. In addition, the ROM of the upper adjacent segment L2/3 in the last follow-up of the rigid group increased significantly, while that of the Isobar TTL group did not change after implantation. Finally, the incidence of adjacent-segment degeneration (ASD) was significantly greater in the rigid group than in the Isobar TTL group according to the UCLA system. CONCLUSION: The Isobar TTL system can be clinically effective for treating two-segment lumbar degenerative disease. Compared with rigid fixation, the Isobar TTL system yielded better radiographic outcomes and maintained the mobility of the treated segments with less impact on the proximal adjacent segment. BioMed Central 2020-01-17 /pmc/articles/PMC6969481/ /pubmed/31952499 http://dx.doi.org/10.1186/s12893-020-0680-8 Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Ji, Zhi-Sheng
Yang, Hua
Yang, Yu-Hao
Li, Shao-Jin
Luo, Jian-Xian
Zhang, Guo-Wei
Lin, Hong-Sheng
Analysis of clinical effect and radiographic outcomes of Isobar TTL system for two-segment lumbar degenerative disease: a retrospective study
title Analysis of clinical effect and radiographic outcomes of Isobar TTL system for two-segment lumbar degenerative disease: a retrospective study
title_full Analysis of clinical effect and radiographic outcomes of Isobar TTL system for two-segment lumbar degenerative disease: a retrospective study
title_fullStr Analysis of clinical effect and radiographic outcomes of Isobar TTL system for two-segment lumbar degenerative disease: a retrospective study
title_full_unstemmed Analysis of clinical effect and radiographic outcomes of Isobar TTL system for two-segment lumbar degenerative disease: a retrospective study
title_short Analysis of clinical effect and radiographic outcomes of Isobar TTL system for two-segment lumbar degenerative disease: a retrospective study
title_sort analysis of clinical effect and radiographic outcomes of isobar ttl system for two-segment lumbar degenerative disease: a retrospective study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6969481/
https://www.ncbi.nlm.nih.gov/pubmed/31952499
http://dx.doi.org/10.1186/s12893-020-0680-8
work_keys_str_mv AT jizhisheng analysisofclinicaleffectandradiographicoutcomesofisobarttlsystemfortwosegmentlumbardegenerativediseasearetrospectivestudy
AT yanghua analysisofclinicaleffectandradiographicoutcomesofisobarttlsystemfortwosegmentlumbardegenerativediseasearetrospectivestudy
AT yangyuhao analysisofclinicaleffectandradiographicoutcomesofisobarttlsystemfortwosegmentlumbardegenerativediseasearetrospectivestudy
AT lishaojin analysisofclinicaleffectandradiographicoutcomesofisobarttlsystemfortwosegmentlumbardegenerativediseasearetrospectivestudy
AT luojianxian analysisofclinicaleffectandradiographicoutcomesofisobarttlsystemfortwosegmentlumbardegenerativediseasearetrospectivestudy
AT zhangguowei analysisofclinicaleffectandradiographicoutcomesofisobarttlsystemfortwosegmentlumbardegenerativediseasearetrospectivestudy
AT linhongsheng analysisofclinicaleffectandradiographicoutcomesofisobarttlsystemfortwosegmentlumbardegenerativediseasearetrospectivestudy