Cargando…

A Modified Customized Rigid Gas Permeable Contact Lens to Improve Visualization During Phacoemulsification in Ectatic Corneas

Advanced Keratoconus and ectatic corneal diseases may lead to corneal thinning and irregular astigmatism. The optical distortion caused by these pathologies may result in poor visibility for the surgeon during phacoemulsification. Thus, the risk of complication would be increased intraoperatively (c...

Descripción completa

Detalles Bibliográficos
Autores principales: Chanbour, Wassef, Harb, Fadi, Jarade, Elias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medical Hypothesis, Discovery & Innovation Ophthalmology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6969555/
https://www.ncbi.nlm.nih.gov/pubmed/31976337
_version_ 1783489346145353728
author Chanbour, Wassef
Harb, Fadi
Jarade, Elias
author_facet Chanbour, Wassef
Harb, Fadi
Jarade, Elias
author_sort Chanbour, Wassef
collection PubMed
description Advanced Keratoconus and ectatic corneal diseases may lead to corneal thinning and irregular astigmatism. The optical distortion caused by these pathologies may result in poor visibility for the surgeon during phacoemulsification. Thus, the risk of complication would be increased intraoperatively (capsular rupture, vitreous loss). The aim of this case series was to use a modified customized Rigid Gas Permeable (RGP) contact lens to improve visualization during all the stages of phacoemulsification in irregular corneas and to avoid open sky technique for cataract removal during penetrating keratoplasty (PK). A customized, 12 mm, RGP contact lens was designed and manufactured. Two peripheral notches were customized to fit the hand position of the surgeon (at 11 O’clock and 2 Clock in this case series) to allow clear corneal incisions. Six eyes of 6 patients were included (3 eyes with advanced keratoconus and a severely optically distorted, yet clear corneas, planned for PK on the same day; 2 eyes were status post-intracorneal ring segment implantation for stage 4 keratoconus and 1 eye had combined phacoemulsification with superficial keratectomy to remove paracentral corneal Salzmann’s nodule). Lens opacities ranged from +2 to +4 nuclear sclerosis in all eyes. Good visualization of the anterior lens and capsule attained with the RGP contact lens fitting. Improved visualization was reported during all the steps (Capsulorhexis, Irrigation/Aspiration, Phaco. Intraocular lens implantation). The phacoemulsification was smooth and non-complicated in a total of 6 eyes of 6 patients. In these cases, without RGP fitting, the operation was not technically possible. The customized notches allowed any insertion of surgical instruments, and with the help of viscoelastic maintained a good stability of the contact lens during the operation. We concluded that customized method RGP contact lens, may help reducing complications during phacoemulsification in advanced corneal ectasia and perhaps in irregular corneas as well.
format Online
Article
Text
id pubmed-6969555
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Medical Hypothesis, Discovery & Innovation Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-69695552020-01-23 A Modified Customized Rigid Gas Permeable Contact Lens to Improve Visualization During Phacoemulsification in Ectatic Corneas Chanbour, Wassef Harb, Fadi Jarade, Elias Med Hypothesis Discov Innov Ophthalmol Original Article Advanced Keratoconus and ectatic corneal diseases may lead to corneal thinning and irregular astigmatism. The optical distortion caused by these pathologies may result in poor visibility for the surgeon during phacoemulsification. Thus, the risk of complication would be increased intraoperatively (capsular rupture, vitreous loss). The aim of this case series was to use a modified customized Rigid Gas Permeable (RGP) contact lens to improve visualization during all the stages of phacoemulsification in irregular corneas and to avoid open sky technique for cataract removal during penetrating keratoplasty (PK). A customized, 12 mm, RGP contact lens was designed and manufactured. Two peripheral notches were customized to fit the hand position of the surgeon (at 11 O’clock and 2 Clock in this case series) to allow clear corneal incisions. Six eyes of 6 patients were included (3 eyes with advanced keratoconus and a severely optically distorted, yet clear corneas, planned for PK on the same day; 2 eyes were status post-intracorneal ring segment implantation for stage 4 keratoconus and 1 eye had combined phacoemulsification with superficial keratectomy to remove paracentral corneal Salzmann’s nodule). Lens opacities ranged from +2 to +4 nuclear sclerosis in all eyes. Good visualization of the anterior lens and capsule attained with the RGP contact lens fitting. Improved visualization was reported during all the steps (Capsulorhexis, Irrigation/Aspiration, Phaco. Intraocular lens implantation). The phacoemulsification was smooth and non-complicated in a total of 6 eyes of 6 patients. In these cases, without RGP fitting, the operation was not technically possible. The customized notches allowed any insertion of surgical instruments, and with the help of viscoelastic maintained a good stability of the contact lens during the operation. We concluded that customized method RGP contact lens, may help reducing complications during phacoemulsification in advanced corneal ectasia and perhaps in irregular corneas as well. Medical Hypothesis, Discovery & Innovation Ophthalmology 2020 2019-11-30 /pmc/articles/PMC6969555/ /pubmed/31976337 Text en © 2020, Author(s). This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial 4.0 International License (http://creativecommons.org/licenses/by/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.
spellingShingle Original Article
Chanbour, Wassef
Harb, Fadi
Jarade, Elias
A Modified Customized Rigid Gas Permeable Contact Lens to Improve Visualization During Phacoemulsification in Ectatic Corneas
title A Modified Customized Rigid Gas Permeable Contact Lens to Improve Visualization During Phacoemulsification in Ectatic Corneas
title_full A Modified Customized Rigid Gas Permeable Contact Lens to Improve Visualization During Phacoemulsification in Ectatic Corneas
title_fullStr A Modified Customized Rigid Gas Permeable Contact Lens to Improve Visualization During Phacoemulsification in Ectatic Corneas
title_full_unstemmed A Modified Customized Rigid Gas Permeable Contact Lens to Improve Visualization During Phacoemulsification in Ectatic Corneas
title_short A Modified Customized Rigid Gas Permeable Contact Lens to Improve Visualization During Phacoemulsification in Ectatic Corneas
title_sort modified customized rigid gas permeable contact lens to improve visualization during phacoemulsification in ectatic corneas
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6969555/
https://www.ncbi.nlm.nih.gov/pubmed/31976337
work_keys_str_mv AT chanbourwassef amodifiedcustomizedrigidgaspermeablecontactlenstoimprovevisualizationduringphacoemulsificationinectaticcorneas
AT harbfadi amodifiedcustomizedrigidgaspermeablecontactlenstoimprovevisualizationduringphacoemulsificationinectaticcorneas
AT jaradeelias amodifiedcustomizedrigidgaspermeablecontactlenstoimprovevisualizationduringphacoemulsificationinectaticcorneas
AT chanbourwassef modifiedcustomizedrigidgaspermeablecontactlenstoimprovevisualizationduringphacoemulsificationinectaticcorneas
AT harbfadi modifiedcustomizedrigidgaspermeablecontactlenstoimprovevisualizationduringphacoemulsificationinectaticcorneas
AT jaradeelias modifiedcustomizedrigidgaspermeablecontactlenstoimprovevisualizationduringphacoemulsificationinectaticcorneas