Cargando…

Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns

BACKGROUND: The purpose of this in vivo study was to compare the marginal and internal gap widths of monolithic zirconia crowns fabricated by CAD/CAM technique and metal-ceramic crowns fabricated by conventional technique. MATERIAL AND METHODS: 10 participants needing a single restoration were selec...

Descripción completa

Detalles Bibliográficos
Autores principales: Paul, Nayana, Raghavendra Swamy, K. N, Dhakshaini, M. R, Sowmya, Sanjukta, Ravi, M. B
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6969964/
https://www.ncbi.nlm.nih.gov/pubmed/31976041
http://dx.doi.org/10.4317/jced.55946
_version_ 1783489421248561152
author Paul, Nayana
Raghavendra Swamy, K. N
Dhakshaini, M. R
Sowmya, Sanjukta
Ravi, M. B
author_facet Paul, Nayana
Raghavendra Swamy, K. N
Dhakshaini, M. R
Sowmya, Sanjukta
Ravi, M. B
author_sort Paul, Nayana
collection PubMed
description BACKGROUND: The purpose of this in vivo study was to compare the marginal and internal gap widths of monolithic zirconia crowns fabricated by CAD/CAM technique and metal-ceramic crowns fabricated by conventional technique. MATERIAL AND METHODS: 10 participants needing a single restoration were selected. Zirconia crowns using CAD/CAM technology (Group A) (n=10) and metal-ceramic crowns (Group B) (n=10) using lost wax casting technique were fabricated for each selected tooth. The marginal and internal gaps of crowns were recorded using a replica technique with light body silicone material stabilized with a regular set putty. Each replica was sectioned buccolingually and mesiodistally and then evaluated at five pre-determined sites. The points measured were PM for marginal gap, PA for axial gap, PAO for axio-occlusal transition gap and PO and PCO for occlusal gaps using a stereomicroscope at 30× magnification. The Paired Sample (t) test was used to detect significant differences between the two groups in terms of marginal and internal fit (α= 0.05). RESULTS: The mean for the marginal gap was 77.42μm (±39.5μm) for Group A compared with 95.86μm (±55.12μm) for Group B. Mean values for internal gap was 87.24 (±21.7 µm) for Group A and 132.91 µm (± 50.63 µm) for Group B. Significant differences were observed between both the groups for marginal (p=.010) and internal (p=.000) fit. CONCLUSIONS: The CAD/CAM fabricated zirconia crowns demonstrated a better accuracy of fit when compared to metal-ceramic crowns fabricated by conventional technology. Key words:Marginal fit, Internal fit, Computer-aided design/computer-aided manufacturing (CAD/CAM).
format Online
Article
Text
id pubmed-6969964
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-69699642020-01-23 Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns Paul, Nayana Raghavendra Swamy, K. N Dhakshaini, M. R Sowmya, Sanjukta Ravi, M. B J Clin Exp Dent Research BACKGROUND: The purpose of this in vivo study was to compare the marginal and internal gap widths of monolithic zirconia crowns fabricated by CAD/CAM technique and metal-ceramic crowns fabricated by conventional technique. MATERIAL AND METHODS: 10 participants needing a single restoration were selected. Zirconia crowns using CAD/CAM technology (Group A) (n=10) and metal-ceramic crowns (Group B) (n=10) using lost wax casting technique were fabricated for each selected tooth. The marginal and internal gaps of crowns were recorded using a replica technique with light body silicone material stabilized with a regular set putty. Each replica was sectioned buccolingually and mesiodistally and then evaluated at five pre-determined sites. The points measured were PM for marginal gap, PA for axial gap, PAO for axio-occlusal transition gap and PO and PCO for occlusal gaps using a stereomicroscope at 30× magnification. The Paired Sample (t) test was used to detect significant differences between the two groups in terms of marginal and internal fit (α= 0.05). RESULTS: The mean for the marginal gap was 77.42μm (±39.5μm) for Group A compared with 95.86μm (±55.12μm) for Group B. Mean values for internal gap was 87.24 (±21.7 µm) for Group A and 132.91 µm (± 50.63 µm) for Group B. Significant differences were observed between both the groups for marginal (p=.010) and internal (p=.000) fit. CONCLUSIONS: The CAD/CAM fabricated zirconia crowns demonstrated a better accuracy of fit when compared to metal-ceramic crowns fabricated by conventional technology. Key words:Marginal fit, Internal fit, Computer-aided design/computer-aided manufacturing (CAD/CAM). Medicina Oral S.L. 2020-01-01 /pmc/articles/PMC6969964/ /pubmed/31976041 http://dx.doi.org/10.4317/jced.55946 Text en Copyright: © 2020 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Paul, Nayana
Raghavendra Swamy, K. N
Dhakshaini, M. R
Sowmya, Sanjukta
Ravi, M. B
Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
title Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
title_full Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
title_fullStr Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
title_full_unstemmed Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
title_short Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
title_sort marginal and internal fit evaluation of conventional metal-ceramic versus zirconia cad/cam crowns
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6969964/
https://www.ncbi.nlm.nih.gov/pubmed/31976041
http://dx.doi.org/10.4317/jced.55946
work_keys_str_mv AT paulnayana marginalandinternalfitevaluationofconventionalmetalceramicversuszirconiacadcamcrowns
AT raghavendraswamykn marginalandinternalfitevaluationofconventionalmetalceramicversuszirconiacadcamcrowns
AT dhakshainimr marginalandinternalfitevaluationofconventionalmetalceramicversuszirconiacadcamcrowns
AT sowmyasanjukta marginalandinternalfitevaluationofconventionalmetalceramicversuszirconiacadcamcrowns
AT ravimb marginalandinternalfitevaluationofconventionalmetalceramicversuszirconiacadcamcrowns