Cargando…
Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: Normal behavior and validation in patients with amyloidosis
BACKGROUND: T1 mapping using modified Look-Locker inversion recovery (MOLLI) provides quantitative information on myocardial tissue composition. T1 results differ between sites due to variations in hardware and software equipment, limiting the comparability of results. The aim was to test if Z-score...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6970284/ https://www.ncbi.nlm.nih.gov/pubmed/31955712 http://dx.doi.org/10.1186/s12968-019-0595-7 |
_version_ | 1783489488745398272 |
---|---|
author | Kranzusch, Riccardo aus dem Siepen, Fabian Wiesemann, Stephanie Zange, Leonora Jeuthe, Sarah Ferreira da Silva, Tiago Kuehne, Titus Pieske, Burkert Tillmanns, Christoph Friedrich, Matthias G. Schulz-Menger, Jeanette Messroghli, Daniel R. |
author_facet | Kranzusch, Riccardo aus dem Siepen, Fabian Wiesemann, Stephanie Zange, Leonora Jeuthe, Sarah Ferreira da Silva, Tiago Kuehne, Titus Pieske, Burkert Tillmanns, Christoph Friedrich, Matthias G. Schulz-Menger, Jeanette Messroghli, Daniel R. |
author_sort | Kranzusch, Riccardo |
collection | PubMed |
description | BACKGROUND: T1 mapping using modified Look-Locker inversion recovery (MOLLI) provides quantitative information on myocardial tissue composition. T1 results differ between sites due to variations in hardware and software equipment, limiting the comparability of results. The aim was to test if Z-scores can be used to compare the results of MOLLI T1 mapping from different cardiovascular magnetic resonance (CMR) platforms. METHODS: First, healthy subjects (n = 15) underwent 11 combinations of native short-axis T1 mapping (four CMR systems from two manufacturers at 1.5 T and 3 T, three MOLLI schemes). Mean and standard deviation (SD) of septal myocardial T1 were derived for each combination. T1 maps were transformed into Z-score maps based on mean and SD values using a prototype post-processing module. Second, Z-score mapping was applied to a validation sample of patients with cardiac amyloidosis at 1.5 T (n = 25) or 3 T (n = 13). RESULTS: In conventional T1 analysis, results were confounded by variations in field strength, MOLLI scheme, and manufacturer-specific system characteristics. Z-score-based analysis yielded consistent results without significant differences between any two of the combinations in part 1 of the study. In the validation sample, Z-score mapping differentiated between patients with cardiac amyloidosis and healthy subjects with the same diagnostic accuracy as standard T1 analysis regardless of field strength. CONCLUSIONS: T1 analysis based on Z-score mapping provides consistent results without significant differences due to field strengths, CMR systems, or MOLLI variants, and detects cardiac amyloidosis with the same diagnostic accuracy as conventional T1 analysis. Z-score mapping provides a means to compare native T1 results acquired with MOLLI across different CMR platforms. |
format | Online Article Text |
id | pubmed-6970284 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-69702842020-01-27 Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: Normal behavior and validation in patients with amyloidosis Kranzusch, Riccardo aus dem Siepen, Fabian Wiesemann, Stephanie Zange, Leonora Jeuthe, Sarah Ferreira da Silva, Tiago Kuehne, Titus Pieske, Burkert Tillmanns, Christoph Friedrich, Matthias G. Schulz-Menger, Jeanette Messroghli, Daniel R. J Cardiovasc Magn Reson Research BACKGROUND: T1 mapping using modified Look-Locker inversion recovery (MOLLI) provides quantitative information on myocardial tissue composition. T1 results differ between sites due to variations in hardware and software equipment, limiting the comparability of results. The aim was to test if Z-scores can be used to compare the results of MOLLI T1 mapping from different cardiovascular magnetic resonance (CMR) platforms. METHODS: First, healthy subjects (n = 15) underwent 11 combinations of native short-axis T1 mapping (four CMR systems from two manufacturers at 1.5 T and 3 T, three MOLLI schemes). Mean and standard deviation (SD) of septal myocardial T1 were derived for each combination. T1 maps were transformed into Z-score maps based on mean and SD values using a prototype post-processing module. Second, Z-score mapping was applied to a validation sample of patients with cardiac amyloidosis at 1.5 T (n = 25) or 3 T (n = 13). RESULTS: In conventional T1 analysis, results were confounded by variations in field strength, MOLLI scheme, and manufacturer-specific system characteristics. Z-score-based analysis yielded consistent results without significant differences between any two of the combinations in part 1 of the study. In the validation sample, Z-score mapping differentiated between patients with cardiac amyloidosis and healthy subjects with the same diagnostic accuracy as standard T1 analysis regardless of field strength. CONCLUSIONS: T1 analysis based on Z-score mapping provides consistent results without significant differences due to field strengths, CMR systems, or MOLLI variants, and detects cardiac amyloidosis with the same diagnostic accuracy as conventional T1 analysis. Z-score mapping provides a means to compare native T1 results acquired with MOLLI across different CMR platforms. BioMed Central 2020-01-20 /pmc/articles/PMC6970284/ /pubmed/31955712 http://dx.doi.org/10.1186/s12968-019-0595-7 Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Kranzusch, Riccardo aus dem Siepen, Fabian Wiesemann, Stephanie Zange, Leonora Jeuthe, Sarah Ferreira da Silva, Tiago Kuehne, Titus Pieske, Burkert Tillmanns, Christoph Friedrich, Matthias G. Schulz-Menger, Jeanette Messroghli, Daniel R. Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: Normal behavior and validation in patients with amyloidosis |
title | Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: Normal behavior and validation in patients with amyloidosis |
title_full | Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: Normal behavior and validation in patients with amyloidosis |
title_fullStr | Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: Normal behavior and validation in patients with amyloidosis |
title_full_unstemmed | Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: Normal behavior and validation in patients with amyloidosis |
title_short | Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: Normal behavior and validation in patients with amyloidosis |
title_sort | z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified look-locker inversion recovery (molli) t1 data: normal behavior and validation in patients with amyloidosis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6970284/ https://www.ncbi.nlm.nih.gov/pubmed/31955712 http://dx.doi.org/10.1186/s12968-019-0595-7 |
work_keys_str_mv | AT kranzuschriccardo zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT ausdemsiepenfabian zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT wiesemannstephanie zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT zangeleonora zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT jeuthesarah zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT ferreiradasilvatiago zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT kuehnetitus zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT pieskeburkert zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT tillmannschristoph zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT friedrichmatthiasg zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT schulzmengerjeanette zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis AT messroghlidanielr zscoremappingforstandardizedanalysisandreportingofcardiovascularmagneticresonancemodifiedlooklockerinversionrecoverymollit1datanormalbehaviorandvalidationinpatientswithamyloidosis |