Cargando…
Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy
This study aimed to compare screw placement accuracy and clinical aspects between Augmented Reality Surgical Navigation (ARSN) and free-hand (FH) technique. Twenty patients underwent spine surgery with screw placement using ARSN and were matched retrospectively to a cohort of 20 FH technique cases f...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6971085/ https://www.ncbi.nlm.nih.gov/pubmed/31959895 http://dx.doi.org/10.1038/s41598-020-57693-5 |
_version_ | 1783489646134558720 |
---|---|
author | Elmi-Terander, Adrian Burström, Gustav Nachabé, Rami Fagerlund, Michael Ståhl, Fredrik Charalampidis, Anastasios Edström, Erik Gerdhem, Paul |
author_facet | Elmi-Terander, Adrian Burström, Gustav Nachabé, Rami Fagerlund, Michael Ståhl, Fredrik Charalampidis, Anastasios Edström, Erik Gerdhem, Paul |
author_sort | Elmi-Terander, Adrian |
collection | PubMed |
description | This study aimed to compare screw placement accuracy and clinical aspects between Augmented Reality Surgical Navigation (ARSN) and free-hand (FH) technique. Twenty patients underwent spine surgery with screw placement using ARSN and were matched retrospectively to a cohort of 20 FH technique cases for comparison. All ARSN and FH cases were performed by the same surgeon. Matching was based on clinical diagnosis and similar proportions of screws placed in the thoracic and lumbosacral vertebrae in both groups. Accuracy of screw placement was assessed on postoperative scans according to the Gertzbein scale and grades 0 and 1 were considered accurate. Procedure time, blood loss and length of hospital stay, were collected as secondary endpoints. A total of 262 and 288 screws were assessed in the ARSN and FH groups, respectively. The share of clinically accurate screws was significantly higher in the ARSN vs FH group (93.9% vs 89.6%, p < 0.05). The proportion of screws placed without a cortical breach was twice as high in the ARSN group compared to the FH group (63.4% vs 30.6%, p < 0.0001). No statistical difference was observed for the secondary endpoints between both groups. This matched-control study demonstrated that ARSN provided higher screw placement accuracy compared to free-hand. |
format | Online Article Text |
id | pubmed-6971085 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-69710852020-01-27 Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy Elmi-Terander, Adrian Burström, Gustav Nachabé, Rami Fagerlund, Michael Ståhl, Fredrik Charalampidis, Anastasios Edström, Erik Gerdhem, Paul Sci Rep Article This study aimed to compare screw placement accuracy and clinical aspects between Augmented Reality Surgical Navigation (ARSN) and free-hand (FH) technique. Twenty patients underwent spine surgery with screw placement using ARSN and were matched retrospectively to a cohort of 20 FH technique cases for comparison. All ARSN and FH cases were performed by the same surgeon. Matching was based on clinical diagnosis and similar proportions of screws placed in the thoracic and lumbosacral vertebrae in both groups. Accuracy of screw placement was assessed on postoperative scans according to the Gertzbein scale and grades 0 and 1 were considered accurate. Procedure time, blood loss and length of hospital stay, were collected as secondary endpoints. A total of 262 and 288 screws were assessed in the ARSN and FH groups, respectively. The share of clinically accurate screws was significantly higher in the ARSN vs FH group (93.9% vs 89.6%, p < 0.05). The proportion of screws placed without a cortical breach was twice as high in the ARSN group compared to the FH group (63.4% vs 30.6%, p < 0.0001). No statistical difference was observed for the secondary endpoints between both groups. This matched-control study demonstrated that ARSN provided higher screw placement accuracy compared to free-hand. Nature Publishing Group UK 2020-01-20 /pmc/articles/PMC6971085/ /pubmed/31959895 http://dx.doi.org/10.1038/s41598-020-57693-5 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Elmi-Terander, Adrian Burström, Gustav Nachabé, Rami Fagerlund, Michael Ståhl, Fredrik Charalampidis, Anastasios Edström, Erik Gerdhem, Paul Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy |
title | Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy |
title_full | Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy |
title_fullStr | Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy |
title_full_unstemmed | Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy |
title_short | Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy |
title_sort | augmented reality navigation with intraoperative 3d imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6971085/ https://www.ncbi.nlm.nih.gov/pubmed/31959895 http://dx.doi.org/10.1038/s41598-020-57693-5 |
work_keys_str_mv | AT elmiteranderadrian augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy AT burstromgustav augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy AT nachaberami augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy AT fagerlundmichael augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy AT stahlfredrik augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy AT charalampidisanastasios augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy AT edstromerik augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy AT gerdhempaul augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy |