Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy

This study aimed to compare screw placement accuracy and clinical aspects between Augmented Reality Surgical Navigation (ARSN) and free-hand (FH) technique. Twenty patients underwent spine surgery with screw placement using ARSN and were matched retrospectively to a cohort of 20 FH technique cases f...

Descripción completa

Detalles Bibliográficos
Autores principales: Elmi-Terander, Adrian, Burström, Gustav, Nachabé, Rami, Fagerlund, Michael, Ståhl, Fredrik, Charalampidis, Anastasios, Edström, Erik, Gerdhem, Paul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6971085/
https://www.ncbi.nlm.nih.gov/pubmed/31959895
http://dx.doi.org/10.1038/s41598-020-57693-5
_version_ 1783489646134558720
author Elmi-Terander, Adrian
Burström, Gustav
Nachabé, Rami
Fagerlund, Michael
Ståhl, Fredrik
Charalampidis, Anastasios
Edström, Erik
Gerdhem, Paul
author_facet Elmi-Terander, Adrian
Burström, Gustav
Nachabé, Rami
Fagerlund, Michael
Ståhl, Fredrik
Charalampidis, Anastasios
Edström, Erik
Gerdhem, Paul
author_sort Elmi-Terander, Adrian
collection PubMed
description This study aimed to compare screw placement accuracy and clinical aspects between Augmented Reality Surgical Navigation (ARSN) and free-hand (FH) technique. Twenty patients underwent spine surgery with screw placement using ARSN and were matched retrospectively to a cohort of 20 FH technique cases for comparison. All ARSN and FH cases were performed by the same surgeon. Matching was based on clinical diagnosis and similar proportions of screws placed in the thoracic and lumbosacral vertebrae in both groups. Accuracy of screw placement was assessed on postoperative scans according to the Gertzbein scale and grades 0 and 1 were considered accurate. Procedure time, blood loss and length of hospital stay, were collected as secondary endpoints. A total of 262 and 288 screws were assessed in the ARSN and FH groups, respectively. The share of clinically accurate screws was significantly higher in the ARSN vs FH group (93.9% vs 89.6%, p < 0.05). The proportion of screws placed without a cortical breach was twice as high in the ARSN group compared to the FH group (63.4% vs 30.6%, p < 0.0001). No statistical difference was observed for the secondary endpoints between both groups. This matched-control study demonstrated that ARSN provided higher screw placement accuracy compared to free-hand.
format Online
Article
Text
id pubmed-6971085
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-69710852020-01-27 Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy Elmi-Terander, Adrian Burström, Gustav Nachabé, Rami Fagerlund, Michael Ståhl, Fredrik Charalampidis, Anastasios Edström, Erik Gerdhem, Paul Sci Rep Article This study aimed to compare screw placement accuracy and clinical aspects between Augmented Reality Surgical Navigation (ARSN) and free-hand (FH) technique. Twenty patients underwent spine surgery with screw placement using ARSN and were matched retrospectively to a cohort of 20 FH technique cases for comparison. All ARSN and FH cases were performed by the same surgeon. Matching was based on clinical diagnosis and similar proportions of screws placed in the thoracic and lumbosacral vertebrae in both groups. Accuracy of screw placement was assessed on postoperative scans according to the Gertzbein scale and grades 0 and 1 were considered accurate. Procedure time, blood loss and length of hospital stay, were collected as secondary endpoints. A total of 262 and 288 screws were assessed in the ARSN and FH groups, respectively. The share of clinically accurate screws was significantly higher in the ARSN vs FH group (93.9% vs 89.6%, p < 0.05). The proportion of screws placed without a cortical breach was twice as high in the ARSN group compared to the FH group (63.4% vs 30.6%, p < 0.0001). No statistical difference was observed for the secondary endpoints between both groups. This matched-control study demonstrated that ARSN provided higher screw placement accuracy compared to free-hand. Nature Publishing Group UK 2020-01-20 /pmc/articles/PMC6971085/ /pubmed/31959895 http://dx.doi.org/10.1038/s41598-020-57693-5 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Elmi-Terander, Adrian
Burström, Gustav
Nachabé, Rami
Fagerlund, Michael
Ståhl, Fredrik
Charalampidis, Anastasios
Edström, Erik
Gerdhem, Paul
Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy
title Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy
title_full Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy
title_fullStr Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy
title_full_unstemmed Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy
title_short Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy
title_sort augmented reality navigation with intraoperative 3d imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6971085/
https://www.ncbi.nlm.nih.gov/pubmed/31959895
http://dx.doi.org/10.1038/s41598-020-57693-5
work_keys_str_mv AT elmiteranderadrian augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy
AT burstromgustav augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy
AT nachaberami augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy
AT fagerlundmichael augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy
AT stahlfredrik augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy
AT charalampidisanastasios augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy
AT edstromerik augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy
AT gerdhempaul augmentedrealitynavigationwithintraoperative3dimagingvsfluoroscopyassistedfreehandsurgeryforspinefixationsurgeryamatchedcontrolstudycomparingaccuracy