Cargando…

Comparative Evaluation of the Masking Ability of Lithium Disilicate Ceramic with Different Core Thickness on the Shade Match of Indirect Restorations over Metallic Substrate: An In vitro Study

PURPOSE: The purpose of this in vitro study was to comparatively evaluate the masking ability of lithium disilicate ceramic with different core thickness on the shade match of indirect restorations over metallic substrate. MATERIALS AND METHODS: A total of 30 heat pressed lithium disilicate ceramic...

Descripción completa

Detalles Bibliográficos
Autores principales: Thilagar, Priyadarshini, Sampathkumar, Jayakrishnakumar, Krishnan, Chitra Shankar, Ramakrishnan, Hariharan, Ramasubramanian, Hariharan, Azhagarasan, N. S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6974991/
https://www.ncbi.nlm.nih.gov/pubmed/32015643
http://dx.doi.org/10.4103/ccd.ccd_301_18
_version_ 1783490210880815104
author Thilagar, Priyadarshini
Sampathkumar, Jayakrishnakumar
Krishnan, Chitra Shankar
Ramakrishnan, Hariharan
Ramasubramanian, Hariharan
Azhagarasan, N. S.
author_facet Thilagar, Priyadarshini
Sampathkumar, Jayakrishnakumar
Krishnan, Chitra Shankar
Ramakrishnan, Hariharan
Ramasubramanian, Hariharan
Azhagarasan, N. S.
author_sort Thilagar, Priyadarshini
collection PubMed
description PURPOSE: The purpose of this in vitro study was to comparatively evaluate the masking ability of lithium disilicate ceramic with different core thickness on the shade match of indirect restorations over metallic substrate. MATERIALS AND METHODS: A total of 30 heat pressed lithium disilicate ceramic discs of low translucency were fabricated with diameter 10mm and thickness of 1 mm, 1.3 mm and 1.6mm with each thickness consisting of 10 samples to be used in the study. Thirty Ni-Cr metal discs of diameter 10mm were used to simulate metallic substrates .The colour difference of the lithium disilicate ceramic disc before and after cementation were measured using CIE LAB system. RESULTS: The mean colour difference (ΔE) of Group I,Group II, Group III before cementation with the Ni-Cr metal discs was 17.32,13.01 and 11.73 respectively. The mean colour difference (ΔE) of Group I,Group II, Group III after cementation with the Ni-Cr metal discs was 16.32,12.10, 11.05 respectively. CONCLUSION: The mean colour difference of the three groups were found to be more than the clinically acceptable perceptibility threshold (ΔE < 3.3) indicative of reduced masking ability of all the three groups of ceramic discs over metallic substrate used in this study.
format Online
Article
Text
id pubmed-6974991
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-69749912020-02-03 Comparative Evaluation of the Masking Ability of Lithium Disilicate Ceramic with Different Core Thickness on the Shade Match of Indirect Restorations over Metallic Substrate: An In vitro Study Thilagar, Priyadarshini Sampathkumar, Jayakrishnakumar Krishnan, Chitra Shankar Ramakrishnan, Hariharan Ramasubramanian, Hariharan Azhagarasan, N. S. Contemp Clin Dent Original Article PURPOSE: The purpose of this in vitro study was to comparatively evaluate the masking ability of lithium disilicate ceramic with different core thickness on the shade match of indirect restorations over metallic substrate. MATERIALS AND METHODS: A total of 30 heat pressed lithium disilicate ceramic discs of low translucency were fabricated with diameter 10mm and thickness of 1 mm, 1.3 mm and 1.6mm with each thickness consisting of 10 samples to be used in the study. Thirty Ni-Cr metal discs of diameter 10mm were used to simulate metallic substrates .The colour difference of the lithium disilicate ceramic disc before and after cementation were measured using CIE LAB system. RESULTS: The mean colour difference (ΔE) of Group I,Group II, Group III before cementation with the Ni-Cr metal discs was 17.32,13.01 and 11.73 respectively. The mean colour difference (ΔE) of Group I,Group II, Group III after cementation with the Ni-Cr metal discs was 16.32,12.10, 11.05 respectively. CONCLUSION: The mean colour difference of the three groups were found to be more than the clinically acceptable perceptibility threshold (ΔE < 3.3) indicative of reduced masking ability of all the three groups of ceramic discs over metallic substrate used in this study. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC6974991/ /pubmed/32015643 http://dx.doi.org/10.4103/ccd.ccd_301_18 Text en Copyright: © 2019 Contemporary Clinical Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Thilagar, Priyadarshini
Sampathkumar, Jayakrishnakumar
Krishnan, Chitra Shankar
Ramakrishnan, Hariharan
Ramasubramanian, Hariharan
Azhagarasan, N. S.
Comparative Evaluation of the Masking Ability of Lithium Disilicate Ceramic with Different Core Thickness on the Shade Match of Indirect Restorations over Metallic Substrate: An In vitro Study
title Comparative Evaluation of the Masking Ability of Lithium Disilicate Ceramic with Different Core Thickness on the Shade Match of Indirect Restorations over Metallic Substrate: An In vitro Study
title_full Comparative Evaluation of the Masking Ability of Lithium Disilicate Ceramic with Different Core Thickness on the Shade Match of Indirect Restorations over Metallic Substrate: An In vitro Study
title_fullStr Comparative Evaluation of the Masking Ability of Lithium Disilicate Ceramic with Different Core Thickness on the Shade Match of Indirect Restorations over Metallic Substrate: An In vitro Study
title_full_unstemmed Comparative Evaluation of the Masking Ability of Lithium Disilicate Ceramic with Different Core Thickness on the Shade Match of Indirect Restorations over Metallic Substrate: An In vitro Study
title_short Comparative Evaluation of the Masking Ability of Lithium Disilicate Ceramic with Different Core Thickness on the Shade Match of Indirect Restorations over Metallic Substrate: An In vitro Study
title_sort comparative evaluation of the masking ability of lithium disilicate ceramic with different core thickness on the shade match of indirect restorations over metallic substrate: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6974991/
https://www.ncbi.nlm.nih.gov/pubmed/32015643
http://dx.doi.org/10.4103/ccd.ccd_301_18
work_keys_str_mv AT thilagarpriyadarshini comparativeevaluationofthemaskingabilityoflithiumdisilicateceramicwithdifferentcorethicknessontheshadematchofindirectrestorationsovermetallicsubstrateaninvitrostudy
AT sampathkumarjayakrishnakumar comparativeevaluationofthemaskingabilityoflithiumdisilicateceramicwithdifferentcorethicknessontheshadematchofindirectrestorationsovermetallicsubstrateaninvitrostudy
AT krishnanchitrashankar comparativeevaluationofthemaskingabilityoflithiumdisilicateceramicwithdifferentcorethicknessontheshadematchofindirectrestorationsovermetallicsubstrateaninvitrostudy
AT ramakrishnanhariharan comparativeevaluationofthemaskingabilityoflithiumdisilicateceramicwithdifferentcorethicknessontheshadematchofindirectrestorationsovermetallicsubstrateaninvitrostudy
AT ramasubramanianhariharan comparativeevaluationofthemaskingabilityoflithiumdisilicateceramicwithdifferentcorethicknessontheshadematchofindirectrestorationsovermetallicsubstrateaninvitrostudy
AT azhagarasanns comparativeevaluationofthemaskingabilityoflithiumdisilicateceramicwithdifferentcorethicknessontheshadematchofindirectrestorationsovermetallicsubstrateaninvitrostudy