Cargando…

Two-wavelength oximetry of tissue microcirculation based on sidestream dark-field imaging

Monitoring oxygen saturation ([Formula: see text]) in microcirculation is effective for understanding disease dynamics. We have developed an [Formula: see text] estimation method, sidestream dark-field (SDF) oximetry, based on SDF imaging. SDF imaging is a noninvasive and clinically applicable techn...

Descripción completa

Detalles Bibliográficos
Autores principales: Hashimoto, Ryohei, Kurata, Tomohiro, Sekine, Masashi, Nakano, Kazuya, Ohnishi, Takashi, Haneishi, Hideaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6975279/
https://www.ncbi.nlm.nih.gov/pubmed/30378349
http://dx.doi.org/10.1117/1.JBO.24.3.031013
_version_ 1783490259804225536
author Hashimoto, Ryohei
Kurata, Tomohiro
Sekine, Masashi
Nakano, Kazuya
Ohnishi, Takashi
Haneishi, Hideaki
author_facet Hashimoto, Ryohei
Kurata, Tomohiro
Sekine, Masashi
Nakano, Kazuya
Ohnishi, Takashi
Haneishi, Hideaki
author_sort Hashimoto, Ryohei
collection PubMed
description Monitoring oxygen saturation ([Formula: see text]) in microcirculation is effective for understanding disease dynamics. We have developed an [Formula: see text] estimation method, sidestream dark-field (SDF) oximetry, based on SDF imaging. SDF imaging is a noninvasive and clinically applicable technique to observe microcirculation. We report the first in vivo experiment observing the changes in [Formula: see text] of microcirculation using SDF oximetry. First, heat from the light-emitting diodes used for the SDF imaging might affect hemodynamics in microcirculation, hence, we performed an experiment to evaluate the influence of that on the SDF oximetry. The result suggested that SDF oximetry had enough stability for long-term experiments. Then, to evaluate the sensitivity of SDF oximetry to alterations in the hemodynamics of the microcirculation, we observed the time-lapsed [Formula: see text] changes in the dermis microcirculation of rats under hypoxic stimulation. We confirmed that the [Formula: see text] estimated by SDF oximetry was in accordance with changes in the fraction of inspired oxygen ([Formula: see text]). Thus, SDF oximetry is considered to be able to observe [Formula: see text] changes that occur in accordance with alteration of the microcirculation.
format Online
Article
Text
id pubmed-6975279
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-69752792020-02-03 Two-wavelength oximetry of tissue microcirculation based on sidestream dark-field imaging Hashimoto, Ryohei Kurata, Tomohiro Sekine, Masashi Nakano, Kazuya Ohnishi, Takashi Haneishi, Hideaki J Biomed Opt Special Section on Biomedical Imaging and Sensing Monitoring oxygen saturation ([Formula: see text]) in microcirculation is effective for understanding disease dynamics. We have developed an [Formula: see text] estimation method, sidestream dark-field (SDF) oximetry, based on SDF imaging. SDF imaging is a noninvasive and clinically applicable technique to observe microcirculation. We report the first in vivo experiment observing the changes in [Formula: see text] of microcirculation using SDF oximetry. First, heat from the light-emitting diodes used for the SDF imaging might affect hemodynamics in microcirculation, hence, we performed an experiment to evaluate the influence of that on the SDF oximetry. The result suggested that SDF oximetry had enough stability for long-term experiments. Then, to evaluate the sensitivity of SDF oximetry to alterations in the hemodynamics of the microcirculation, we observed the time-lapsed [Formula: see text] changes in the dermis microcirculation of rats under hypoxic stimulation. We confirmed that the [Formula: see text] estimated by SDF oximetry was in accordance with changes in the fraction of inspired oxygen ([Formula: see text]). Thus, SDF oximetry is considered to be able to observe [Formula: see text] changes that occur in accordance with alteration of the microcirculation. Society of Photo-Optical Instrumentation Engineers 2018-10-30 2019-03 /pmc/articles/PMC6975279/ /pubmed/30378349 http://dx.doi.org/10.1117/1.JBO.24.3.031013 Text en © The Authors. https://creativecommons.org/licenses/by/3.0/ Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Special Section on Biomedical Imaging and Sensing
Hashimoto, Ryohei
Kurata, Tomohiro
Sekine, Masashi
Nakano, Kazuya
Ohnishi, Takashi
Haneishi, Hideaki
Two-wavelength oximetry of tissue microcirculation based on sidestream dark-field imaging
title Two-wavelength oximetry of tissue microcirculation based on sidestream dark-field imaging
title_full Two-wavelength oximetry of tissue microcirculation based on sidestream dark-field imaging
title_fullStr Two-wavelength oximetry of tissue microcirculation based on sidestream dark-field imaging
title_full_unstemmed Two-wavelength oximetry of tissue microcirculation based on sidestream dark-field imaging
title_short Two-wavelength oximetry of tissue microcirculation based on sidestream dark-field imaging
title_sort two-wavelength oximetry of tissue microcirculation based on sidestream dark-field imaging
topic Special Section on Biomedical Imaging and Sensing
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6975279/
https://www.ncbi.nlm.nih.gov/pubmed/30378349
http://dx.doi.org/10.1117/1.JBO.24.3.031013
work_keys_str_mv AT hashimotoryohei twowavelengthoximetryoftissuemicrocirculationbasedonsidestreamdarkfieldimaging
AT kuratatomohiro twowavelengthoximetryoftissuemicrocirculationbasedonsidestreamdarkfieldimaging
AT sekinemasashi twowavelengthoximetryoftissuemicrocirculationbasedonsidestreamdarkfieldimaging
AT nakanokazuya twowavelengthoximetryoftissuemicrocirculationbasedonsidestreamdarkfieldimaging
AT ohnishitakashi twowavelengthoximetryoftissuemicrocirculationbasedonsidestreamdarkfieldimaging
AT haneishihideaki twowavelengthoximetryoftissuemicrocirculationbasedonsidestreamdarkfieldimaging