Detecting inflammation in rheumatoid arthritis using Fourier transform analysis of dorsal optical transmission images from a pilot study
A clinical need exists for low-cost and noninvasive imaging tools capable of detecting inflammation in the joints of inflammatory arthritis patients. Previous studies have reported an optical contrast between inflamed and noninflamed joints resulting from distinct absorption and scattering propertie...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6977034/ https://www.ncbi.nlm.nih.gov/pubmed/31222990 http://dx.doi.org/10.1117/1.JBO.24.6.066008 |
_version_ | 1783490423267786752 |
---|---|
author | Lighter, Daniel Filer, Andrew Dehghani, Hamid |
author_facet | Lighter, Daniel Filer, Andrew Dehghani, Hamid |
author_sort | Lighter, Daniel |
collection | PubMed |
description | A clinical need exists for low-cost and noninvasive imaging tools capable of detecting inflammation in the joints of inflammatory arthritis patients. Previous studies have reported an optical contrast between inflamed and noninflamed joints resulting from distinct absorption and scattering properties. Accurate classification using nonocclusion-based continuous wave, transillumination imaging was limited to patient-specific changes during follow-up examination as opposed to single time-point examination, which was attributed to high intersubject variability. In distinction from previous work, optical images were acquired from the dorsal side with illumination on the palmar side and features about the spatial distribution of transmitted light along the joint were assessed using a normalized Fourier transform method. Results using this approach demonstrated an area under receiver operator curve of up to 0.888 for detecting inflammation in a pilot study involving single time-point examination of 144 joints from 21 rheumatology patients. This workflow may enable future development of clinically viable, low-cost devices for assessing inflammation in arthritis patients, without the need for cuff occlusion or comparison to baseline. |
format | Online Article Text |
id | pubmed-6977034 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-69770342020-02-03 Detecting inflammation in rheumatoid arthritis using Fourier transform analysis of dorsal optical transmission images from a pilot study Lighter, Daniel Filer, Andrew Dehghani, Hamid J Biomed Opt Imaging A clinical need exists for low-cost and noninvasive imaging tools capable of detecting inflammation in the joints of inflammatory arthritis patients. Previous studies have reported an optical contrast between inflamed and noninflamed joints resulting from distinct absorption and scattering properties. Accurate classification using nonocclusion-based continuous wave, transillumination imaging was limited to patient-specific changes during follow-up examination as opposed to single time-point examination, which was attributed to high intersubject variability. In distinction from previous work, optical images were acquired from the dorsal side with illumination on the palmar side and features about the spatial distribution of transmitted light along the joint were assessed using a normalized Fourier transform method. Results using this approach demonstrated an area under receiver operator curve of up to 0.888 for detecting inflammation in a pilot study involving single time-point examination of 144 joints from 21 rheumatology patients. This workflow may enable future development of clinically viable, low-cost devices for assessing inflammation in arthritis patients, without the need for cuff occlusion or comparison to baseline. Society of Photo-Optical Instrumentation Engineers 2019-06-20 2019-06 /pmc/articles/PMC6977034/ /pubmed/31222990 http://dx.doi.org/10.1117/1.JBO.24.6.066008 Text en © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Imaging Lighter, Daniel Filer, Andrew Dehghani, Hamid Detecting inflammation in rheumatoid arthritis using Fourier transform analysis of dorsal optical transmission images from a pilot study |
title | Detecting inflammation in rheumatoid arthritis using Fourier transform analysis of dorsal optical transmission images from a pilot study |
title_full | Detecting inflammation in rheumatoid arthritis using Fourier transform analysis of dorsal optical transmission images from a pilot study |
title_fullStr | Detecting inflammation in rheumatoid arthritis using Fourier transform analysis of dorsal optical transmission images from a pilot study |
title_full_unstemmed | Detecting inflammation in rheumatoid arthritis using Fourier transform analysis of dorsal optical transmission images from a pilot study |
title_short | Detecting inflammation in rheumatoid arthritis using Fourier transform analysis of dorsal optical transmission images from a pilot study |
title_sort | detecting inflammation in rheumatoid arthritis using fourier transform analysis of dorsal optical transmission images from a pilot study |
topic | Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6977034/ https://www.ncbi.nlm.nih.gov/pubmed/31222990 http://dx.doi.org/10.1117/1.JBO.24.6.066008 |
work_keys_str_mv | AT lighterdaniel detectinginflammationinrheumatoidarthritisusingfouriertransformanalysisofdorsalopticaltransmissionimagesfromapilotstudy AT filerandrew detectinginflammationinrheumatoidarthritisusingfouriertransformanalysisofdorsalopticaltransmissionimagesfromapilotstudy AT dehghanihamid detectinginflammationinrheumatoidarthritisusingfouriertransformanalysisofdorsalopticaltransmissionimagesfromapilotstudy |