Cargando…
Pseudo-arterial Temporary Hemodialysis Catheter Placement in the Left Internal Jugular Vein Ipsilateral to a Preexisting Brachio-axillary Arteriovenous Graft
Internal jugular vein (IJV) cannulation was originally described by English et al. in 1969 as the safest approach. Carotid artery puncture had an incidence rate of 4–6% before ultrasound guidance. We encountered an unexpected sequence of events following the ultrasound-guided placement of a temporar...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6977375/ https://www.ncbi.nlm.nih.gov/pubmed/32015597 http://dx.doi.org/10.4103/ijn.IJN_389_18 |
_version_ | 1783490496367165440 |
---|---|
author | Onuigbo, Macaulay Amechi Chukwukadibia Agbasi, Nneoma Sarki, Bibek Khan, Sana Wahlberg, Kramer |
author_facet | Onuigbo, Macaulay Amechi Chukwukadibia Agbasi, Nneoma Sarki, Bibek Khan, Sana Wahlberg, Kramer |
author_sort | Onuigbo, Macaulay Amechi Chukwukadibia |
collection | PubMed |
description | Internal jugular vein (IJV) cannulation was originally described by English et al. in 1969 as the safest approach. Carotid artery puncture had an incidence rate of 4–6% before ultrasound guidance. We encountered an unexpected sequence of events following the ultrasound-guided placement of a temporary HD catheter in the left IJV. The postprocedure chest radiograph was misinterpreted as an arterial misplacement, the blood return was correspondingly bright red, and simultaneous blood gas analyses from the left IJV catheter and a right radial artery were near mirror images. Subsequently, a transducer to the catheter showed a clearly venous waveform with a pressure of 40 mmHg. Thus, it was realized that the cacophony of missteps, misjudgments, and misinterpretations was due to the contiguous presence of a functional left brachio-axillary arteriovenous (AV) graft. To our knowledge, this is the first such report of this phenomenon of a pseudo-arterial central venous catheter placement in the IJV. |
format | Online Article Text |
id | pubmed-6977375 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-69773752020-02-03 Pseudo-arterial Temporary Hemodialysis Catheter Placement in the Left Internal Jugular Vein Ipsilateral to a Preexisting Brachio-axillary Arteriovenous Graft Onuigbo, Macaulay Amechi Chukwukadibia Agbasi, Nneoma Sarki, Bibek Khan, Sana Wahlberg, Kramer Indian J Nephrol Case Report Internal jugular vein (IJV) cannulation was originally described by English et al. in 1969 as the safest approach. Carotid artery puncture had an incidence rate of 4–6% before ultrasound guidance. We encountered an unexpected sequence of events following the ultrasound-guided placement of a temporary HD catheter in the left IJV. The postprocedure chest radiograph was misinterpreted as an arterial misplacement, the blood return was correspondingly bright red, and simultaneous blood gas analyses from the left IJV catheter and a right radial artery were near mirror images. Subsequently, a transducer to the catheter showed a clearly venous waveform with a pressure of 40 mmHg. Thus, it was realized that the cacophony of missteps, misjudgments, and misinterpretations was due to the contiguous presence of a functional left brachio-axillary arteriovenous (AV) graft. To our knowledge, this is the first such report of this phenomenon of a pseudo-arterial central venous catheter placement in the IJV. Wolters Kluwer - Medknow 2020 2019-12-27 /pmc/articles/PMC6977375/ /pubmed/32015597 http://dx.doi.org/10.4103/ijn.IJN_389_18 Text en Copyright: © 2020 Indian Journal of Nephrology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Onuigbo, Macaulay Amechi Chukwukadibia Agbasi, Nneoma Sarki, Bibek Khan, Sana Wahlberg, Kramer Pseudo-arterial Temporary Hemodialysis Catheter Placement in the Left Internal Jugular Vein Ipsilateral to a Preexisting Brachio-axillary Arteriovenous Graft |
title | Pseudo-arterial Temporary Hemodialysis Catheter Placement in the Left Internal Jugular Vein Ipsilateral to a Preexisting Brachio-axillary Arteriovenous Graft |
title_full | Pseudo-arterial Temporary Hemodialysis Catheter Placement in the Left Internal Jugular Vein Ipsilateral to a Preexisting Brachio-axillary Arteriovenous Graft |
title_fullStr | Pseudo-arterial Temporary Hemodialysis Catheter Placement in the Left Internal Jugular Vein Ipsilateral to a Preexisting Brachio-axillary Arteriovenous Graft |
title_full_unstemmed | Pseudo-arterial Temporary Hemodialysis Catheter Placement in the Left Internal Jugular Vein Ipsilateral to a Preexisting Brachio-axillary Arteriovenous Graft |
title_short | Pseudo-arterial Temporary Hemodialysis Catheter Placement in the Left Internal Jugular Vein Ipsilateral to a Preexisting Brachio-axillary Arteriovenous Graft |
title_sort | pseudo-arterial temporary hemodialysis catheter placement in the left internal jugular vein ipsilateral to a preexisting brachio-axillary arteriovenous graft |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6977375/ https://www.ncbi.nlm.nih.gov/pubmed/32015597 http://dx.doi.org/10.4103/ijn.IJN_389_18 |
work_keys_str_mv | AT onuigbomacaulayamechichukwukadibia pseudoarterialtemporaryhemodialysiscatheterplacementintheleftinternaljugularveinipsilateraltoapreexistingbrachioaxillaryarteriovenousgraft AT agbasinneoma pseudoarterialtemporaryhemodialysiscatheterplacementintheleftinternaljugularveinipsilateraltoapreexistingbrachioaxillaryarteriovenousgraft AT sarkibibek pseudoarterialtemporaryhemodialysiscatheterplacementintheleftinternaljugularveinipsilateraltoapreexistingbrachioaxillaryarteriovenousgraft AT khansana pseudoarterialtemporaryhemodialysiscatheterplacementintheleftinternaljugularveinipsilateraltoapreexistingbrachioaxillaryarteriovenousgraft AT wahlbergkramer pseudoarterialtemporaryhemodialysiscatheterplacementintheleftinternaljugularveinipsilateraltoapreexistingbrachioaxillaryarteriovenousgraft |