Cargando…

Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage

BACKGROUND: Post-haemorrhagic ventricular dilatation can be measured accurately by MRI. However, two-dimensional (2-D) cranial US can be used at the bedside on a daily basis. OBJECTIVE: To assess whether the ventricular volume can be determined accurately using US. MATERIALS AND METHODS: We included...

Descripción completa

Detalles Bibliográficos
Autores principales: Beijst, Casper, Dudink, Jeroen, Wientjes, Rens, Benavente-Fernandez, Isabel, Groenendaal, Floris, Brouwer, Margaretha J., Išgum, Ivana, de Jong, Hugo W. A. M., de Vries, Linda S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6978291/
https://www.ncbi.nlm.nih.gov/pubmed/31691845
http://dx.doi.org/10.1007/s00247-019-04542-x
_version_ 1783490665878913024
author Beijst, Casper
Dudink, Jeroen
Wientjes, Rens
Benavente-Fernandez, Isabel
Groenendaal, Floris
Brouwer, Margaretha J.
Išgum, Ivana
de Jong, Hugo W. A. M.
de Vries, Linda S.
author_facet Beijst, Casper
Dudink, Jeroen
Wientjes, Rens
Benavente-Fernandez, Isabel
Groenendaal, Floris
Brouwer, Margaretha J.
Išgum, Ivana
de Jong, Hugo W. A. M.
de Vries, Linda S.
author_sort Beijst, Casper
collection PubMed
description BACKGROUND: Post-haemorrhagic ventricular dilatation can be measured accurately by MRI. However, two-dimensional (2-D) cranial US can be used at the bedside on a daily basis. OBJECTIVE: To assess whether the ventricular volume can be determined accurately using US. MATERIALS AND METHODS: We included 31 preterm infants with germinal matrix intraventricular haemorrhage. Two-dimensional cranial US images were acquired and the ventricular index, anterior horn width and thalamo-occipital distance were measured. In addition, cranial MRI was performed. The ventricular volume on MRI was determined using a previously validated automatic segmentation algorithm. We obtained the correlation and created a linear model between MRI-derived ventricular volume and 2-D cranial US measurements. RESULTS: The ventricular index, anterior horn width and thalamo-occipital distance as measured on 2-D cranial US were significantly associated with the volume of the ventricles as determined with MRI. A general linear model fitted the data best: ∛ventricular volume (ml) = 1.096 + 0.094 × anterior horn width (mm) + 0.020 × thalamo-occipital distance (mm) with R(2) = 0.831. CONCLUSION: The volume of the lateral ventricles of infants with germinal matrix intraventricular haemorrhage can be estimated using 2-D cranial US images by application of a model.
format Online
Article
Text
id pubmed-6978291
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-69782912020-02-03 Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage Beijst, Casper Dudink, Jeroen Wientjes, Rens Benavente-Fernandez, Isabel Groenendaal, Floris Brouwer, Margaretha J. Išgum, Ivana de Jong, Hugo W. A. M. de Vries, Linda S. Pediatr Radiol Original Article BACKGROUND: Post-haemorrhagic ventricular dilatation can be measured accurately by MRI. However, two-dimensional (2-D) cranial US can be used at the bedside on a daily basis. OBJECTIVE: To assess whether the ventricular volume can be determined accurately using US. MATERIALS AND METHODS: We included 31 preterm infants with germinal matrix intraventricular haemorrhage. Two-dimensional cranial US images were acquired and the ventricular index, anterior horn width and thalamo-occipital distance were measured. In addition, cranial MRI was performed. The ventricular volume on MRI was determined using a previously validated automatic segmentation algorithm. We obtained the correlation and created a linear model between MRI-derived ventricular volume and 2-D cranial US measurements. RESULTS: The ventricular index, anterior horn width and thalamo-occipital distance as measured on 2-D cranial US were significantly associated with the volume of the ventricles as determined with MRI. A general linear model fitted the data best: ∛ventricular volume (ml) = 1.096 + 0.094 × anterior horn width (mm) + 0.020 × thalamo-occipital distance (mm) with R(2) = 0.831. CONCLUSION: The volume of the lateral ventricles of infants with germinal matrix intraventricular haemorrhage can be estimated using 2-D cranial US images by application of a model. Springer Berlin Heidelberg 2019-11-06 2020 /pmc/articles/PMC6978291/ /pubmed/31691845 http://dx.doi.org/10.1007/s00247-019-04542-x Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Beijst, Casper
Dudink, Jeroen
Wientjes, Rens
Benavente-Fernandez, Isabel
Groenendaal, Floris
Brouwer, Margaretha J.
Išgum, Ivana
de Jong, Hugo W. A. M.
de Vries, Linda S.
Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage
title Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage
title_full Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage
title_fullStr Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage
title_full_unstemmed Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage
title_short Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage
title_sort two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6978291/
https://www.ncbi.nlm.nih.gov/pubmed/31691845
http://dx.doi.org/10.1007/s00247-019-04542-x
work_keys_str_mv AT beijstcasper twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage
AT dudinkjeroen twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage
AT wientjesrens twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage
AT benaventefernandezisabel twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage
AT groenendaalfloris twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage
AT brouwermargarethaj twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage
AT isgumivana twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage
AT dejonghugowam twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage
AT devrieslindas twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage