Cargando…
Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage
BACKGROUND: Post-haemorrhagic ventricular dilatation can be measured accurately by MRI. However, two-dimensional (2-D) cranial US can be used at the bedside on a daily basis. OBJECTIVE: To assess whether the ventricular volume can be determined accurately using US. MATERIALS AND METHODS: We included...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6978291/ https://www.ncbi.nlm.nih.gov/pubmed/31691845 http://dx.doi.org/10.1007/s00247-019-04542-x |
_version_ | 1783490665878913024 |
---|---|
author | Beijst, Casper Dudink, Jeroen Wientjes, Rens Benavente-Fernandez, Isabel Groenendaal, Floris Brouwer, Margaretha J. Išgum, Ivana de Jong, Hugo W. A. M. de Vries, Linda S. |
author_facet | Beijst, Casper Dudink, Jeroen Wientjes, Rens Benavente-Fernandez, Isabel Groenendaal, Floris Brouwer, Margaretha J. Išgum, Ivana de Jong, Hugo W. A. M. de Vries, Linda S. |
author_sort | Beijst, Casper |
collection | PubMed |
description | BACKGROUND: Post-haemorrhagic ventricular dilatation can be measured accurately by MRI. However, two-dimensional (2-D) cranial US can be used at the bedside on a daily basis. OBJECTIVE: To assess whether the ventricular volume can be determined accurately using US. MATERIALS AND METHODS: We included 31 preterm infants with germinal matrix intraventricular haemorrhage. Two-dimensional cranial US images were acquired and the ventricular index, anterior horn width and thalamo-occipital distance were measured. In addition, cranial MRI was performed. The ventricular volume on MRI was determined using a previously validated automatic segmentation algorithm. We obtained the correlation and created a linear model between MRI-derived ventricular volume and 2-D cranial US measurements. RESULTS: The ventricular index, anterior horn width and thalamo-occipital distance as measured on 2-D cranial US were significantly associated with the volume of the ventricles as determined with MRI. A general linear model fitted the data best: ∛ventricular volume (ml) = 1.096 + 0.094 × anterior horn width (mm) + 0.020 × thalamo-occipital distance (mm) with R(2) = 0.831. CONCLUSION: The volume of the lateral ventricles of infants with germinal matrix intraventricular haemorrhage can be estimated using 2-D cranial US images by application of a model. |
format | Online Article Text |
id | pubmed-6978291 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-69782912020-02-03 Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage Beijst, Casper Dudink, Jeroen Wientjes, Rens Benavente-Fernandez, Isabel Groenendaal, Floris Brouwer, Margaretha J. Išgum, Ivana de Jong, Hugo W. A. M. de Vries, Linda S. Pediatr Radiol Original Article BACKGROUND: Post-haemorrhagic ventricular dilatation can be measured accurately by MRI. However, two-dimensional (2-D) cranial US can be used at the bedside on a daily basis. OBJECTIVE: To assess whether the ventricular volume can be determined accurately using US. MATERIALS AND METHODS: We included 31 preterm infants with germinal matrix intraventricular haemorrhage. Two-dimensional cranial US images were acquired and the ventricular index, anterior horn width and thalamo-occipital distance were measured. In addition, cranial MRI was performed. The ventricular volume on MRI was determined using a previously validated automatic segmentation algorithm. We obtained the correlation and created a linear model between MRI-derived ventricular volume and 2-D cranial US measurements. RESULTS: The ventricular index, anterior horn width and thalamo-occipital distance as measured on 2-D cranial US were significantly associated with the volume of the ventricles as determined with MRI. A general linear model fitted the data best: ∛ventricular volume (ml) = 1.096 + 0.094 × anterior horn width (mm) + 0.020 × thalamo-occipital distance (mm) with R(2) = 0.831. CONCLUSION: The volume of the lateral ventricles of infants with germinal matrix intraventricular haemorrhage can be estimated using 2-D cranial US images by application of a model. Springer Berlin Heidelberg 2019-11-06 2020 /pmc/articles/PMC6978291/ /pubmed/31691845 http://dx.doi.org/10.1007/s00247-019-04542-x Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Beijst, Casper Dudink, Jeroen Wientjes, Rens Benavente-Fernandez, Isabel Groenendaal, Floris Brouwer, Margaretha J. Išgum, Ivana de Jong, Hugo W. A. M. de Vries, Linda S. Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage |
title | Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage |
title_full | Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage |
title_fullStr | Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage |
title_full_unstemmed | Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage |
title_short | Two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage |
title_sort | two-dimensional ultrasound measurements vs. magnetic resonance imaging-derived ventricular volume of preterm infants with germinal matrix intraventricular haemorrhage |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6978291/ https://www.ncbi.nlm.nih.gov/pubmed/31691845 http://dx.doi.org/10.1007/s00247-019-04542-x |
work_keys_str_mv | AT beijstcasper twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage AT dudinkjeroen twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage AT wientjesrens twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage AT benaventefernandezisabel twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage AT groenendaalfloris twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage AT brouwermargarethaj twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage AT isgumivana twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage AT dejonghugowam twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage AT devrieslindas twodimensionalultrasoundmeasurementsvsmagneticresonanceimagingderivedventricularvolumeofpreterminfantswithgerminalmatrixintraventricularhaemorrhage |