Cargando…

The Tensile Strength and Damage Characteristic of Two Types of Concrete and Their Interface

In this study, tensile splitting tests and corresponding numerical simulations are performed on high strength concrete, low strength concrete, the interface between the two types of concrete, and the interface reinforced by steel fiber, respectively. The tensile splitting strength, crack initiation...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Qingchuan, Chen, Wei, Liu, Chao, Zou, Wenjie, Pan, Liufeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6981918/
https://www.ncbi.nlm.nih.gov/pubmed/31861416
http://dx.doi.org/10.3390/ma13010016
_version_ 1783491194158841856
author Shen, Qingchuan
Chen, Wei
Liu, Chao
Zou, Wenjie
Pan, Liufeng
author_facet Shen, Qingchuan
Chen, Wei
Liu, Chao
Zou, Wenjie
Pan, Liufeng
author_sort Shen, Qingchuan
collection PubMed
description In this study, tensile splitting tests and corresponding numerical simulations are performed on high strength concrete, low strength concrete, the interface between the two types of concrete, and the interface reinforced by steel fiber, respectively. The tensile splitting strength, crack initiation load, and damage characteristics are analyzed based on experiment data and fracture surface of samples. It can be concluded that tensile splitting strength and crack initiation load have the descending order of ‘HT’ (high strength concrete sample) > ‘LT’ (low strength concrete sample) > ‘FT’ (interface reinforced by steel fiber) > ‘OT’ (interface). The tensile splitting strength is related not only to the roughness of the fracture surface, but also to the percentage of fractured aggregates. The steel fiber can increase initiation cracking load, peak load and residual strength of the interface. The existing of interface composited by two types of material can cause asymmetric distribution of the stress state, even if geometry and the load are symmetrical for samples.
format Online
Article
Text
id pubmed-6981918
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69819182020-02-07 The Tensile Strength and Damage Characteristic of Two Types of Concrete and Their Interface Shen, Qingchuan Chen, Wei Liu, Chao Zou, Wenjie Pan, Liufeng Materials (Basel) Article In this study, tensile splitting tests and corresponding numerical simulations are performed on high strength concrete, low strength concrete, the interface between the two types of concrete, and the interface reinforced by steel fiber, respectively. The tensile splitting strength, crack initiation load, and damage characteristics are analyzed based on experiment data and fracture surface of samples. It can be concluded that tensile splitting strength and crack initiation load have the descending order of ‘HT’ (high strength concrete sample) > ‘LT’ (low strength concrete sample) > ‘FT’ (interface reinforced by steel fiber) > ‘OT’ (interface). The tensile splitting strength is related not only to the roughness of the fracture surface, but also to the percentage of fractured aggregates. The steel fiber can increase initiation cracking load, peak load and residual strength of the interface. The existing of interface composited by two types of material can cause asymmetric distribution of the stress state, even if geometry and the load are symmetrical for samples. MDPI 2019-12-18 /pmc/articles/PMC6981918/ /pubmed/31861416 http://dx.doi.org/10.3390/ma13010016 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shen, Qingchuan
Chen, Wei
Liu, Chao
Zou, Wenjie
Pan, Liufeng
The Tensile Strength and Damage Characteristic of Two Types of Concrete and Their Interface
title The Tensile Strength and Damage Characteristic of Two Types of Concrete and Their Interface
title_full The Tensile Strength and Damage Characteristic of Two Types of Concrete and Their Interface
title_fullStr The Tensile Strength and Damage Characteristic of Two Types of Concrete and Their Interface
title_full_unstemmed The Tensile Strength and Damage Characteristic of Two Types of Concrete and Their Interface
title_short The Tensile Strength and Damage Characteristic of Two Types of Concrete and Their Interface
title_sort tensile strength and damage characteristic of two types of concrete and their interface
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6981918/
https://www.ncbi.nlm.nih.gov/pubmed/31861416
http://dx.doi.org/10.3390/ma13010016
work_keys_str_mv AT shenqingchuan thetensilestrengthanddamagecharacteristicoftwotypesofconcreteandtheirinterface
AT chenwei thetensilestrengthanddamagecharacteristicoftwotypesofconcreteandtheirinterface
AT liuchao thetensilestrengthanddamagecharacteristicoftwotypesofconcreteandtheirinterface
AT zouwenjie thetensilestrengthanddamagecharacteristicoftwotypesofconcreteandtheirinterface
AT panliufeng thetensilestrengthanddamagecharacteristicoftwotypesofconcreteandtheirinterface
AT shenqingchuan tensilestrengthanddamagecharacteristicoftwotypesofconcreteandtheirinterface
AT chenwei tensilestrengthanddamagecharacteristicoftwotypesofconcreteandtheirinterface
AT liuchao tensilestrengthanddamagecharacteristicoftwotypesofconcreteandtheirinterface
AT zouwenjie tensilestrengthanddamagecharacteristicoftwotypesofconcreteandtheirinterface
AT panliufeng tensilestrengthanddamagecharacteristicoftwotypesofconcreteandtheirinterface