A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices
This paper presents a fingertip grip force sensor based on custom capacitive sensors for glove-type assistive devices with an open-pad structure. The design of the sensor allows using human tactile sensations during grasping and manipulating an object. The proposed sensor can be attached on both sid...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6982706/ https://www.ncbi.nlm.nih.gov/pubmed/31861271 http://dx.doi.org/10.3390/s20010004 |
_version_ | 1783491350217359360 |
---|---|
author | Park, Junghoon Heo, Pilwon Kim, Jung Na, Youngjin |
author_facet | Park, Junghoon Heo, Pilwon Kim, Jung Na, Youngjin |
author_sort | Park, Junghoon |
collection | PubMed |
description | This paper presents a fingertip grip force sensor based on custom capacitive sensors for glove-type assistive devices with an open-pad structure. The design of the sensor allows using human tactile sensations during grasping and manipulating an object. The proposed sensor can be attached on both sides of the fingertip and measure the force caused by the expansion of the fingertip tissue when a grasping force is applied to the fingertip. The number of measurable degrees of freedom (DoFs) are the two DoFs (flexion and adduction) for the thumb and one DoF (flexion) for the index and middle fingers. The proposed sensor allows the combination with a glove-type assistive device to measure the fingertip force. Calibration was performed for each finger joint angle because the variations in the expansion of the fingertip tissue depend on the joint angles. The root mean square error (RMSE) for fingertip force estimation ranged from 3.75% to 9.71% after calibration, regardless of the finger joint angles or finger posture. |
format | Online Article Text |
id | pubmed-6982706 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-69827062020-02-28 A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices Park, Junghoon Heo, Pilwon Kim, Jung Na, Youngjin Sensors (Basel) Article This paper presents a fingertip grip force sensor based on custom capacitive sensors for glove-type assistive devices with an open-pad structure. The design of the sensor allows using human tactile sensations during grasping and manipulating an object. The proposed sensor can be attached on both sides of the fingertip and measure the force caused by the expansion of the fingertip tissue when a grasping force is applied to the fingertip. The number of measurable degrees of freedom (DoFs) are the two DoFs (flexion and adduction) for the thumb and one DoF (flexion) for the index and middle fingers. The proposed sensor allows the combination with a glove-type assistive device to measure the fingertip force. Calibration was performed for each finger joint angle because the variations in the expansion of the fingertip tissue depend on the joint angles. The root mean square error (RMSE) for fingertip force estimation ranged from 3.75% to 9.71% after calibration, regardless of the finger joint angles or finger posture. MDPI 2019-12-18 /pmc/articles/PMC6982706/ /pubmed/31861271 http://dx.doi.org/10.3390/s20010004 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Park, Junghoon Heo, Pilwon Kim, Jung Na, Youngjin A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices |
title | A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices |
title_full | A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices |
title_fullStr | A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices |
title_full_unstemmed | A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices |
title_short | A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices |
title_sort | finger grip force sensor with an open-pad structure for glove-type assistive devices |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6982706/ https://www.ncbi.nlm.nih.gov/pubmed/31861271 http://dx.doi.org/10.3390/s20010004 |
work_keys_str_mv | AT parkjunghoon afingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices AT heopilwon afingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices AT kimjung afingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices AT nayoungjin afingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices AT parkjunghoon fingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices AT heopilwon fingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices AT kimjung fingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices AT nayoungjin fingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices |