Cargando…

A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices

This paper presents a fingertip grip force sensor based on custom capacitive sensors for glove-type assistive devices with an open-pad structure. The design of the sensor allows using human tactile sensations during grasping and manipulating an object. The proposed sensor can be attached on both sid...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Junghoon, Heo, Pilwon, Kim, Jung, Na, Youngjin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6982706/
https://www.ncbi.nlm.nih.gov/pubmed/31861271
http://dx.doi.org/10.3390/s20010004
_version_ 1783491350217359360
author Park, Junghoon
Heo, Pilwon
Kim, Jung
Na, Youngjin
author_facet Park, Junghoon
Heo, Pilwon
Kim, Jung
Na, Youngjin
author_sort Park, Junghoon
collection PubMed
description This paper presents a fingertip grip force sensor based on custom capacitive sensors for glove-type assistive devices with an open-pad structure. The design of the sensor allows using human tactile sensations during grasping and manipulating an object. The proposed sensor can be attached on both sides of the fingertip and measure the force caused by the expansion of the fingertip tissue when a grasping force is applied to the fingertip. The number of measurable degrees of freedom (DoFs) are the two DoFs (flexion and adduction) for the thumb and one DoF (flexion) for the index and middle fingers. The proposed sensor allows the combination with a glove-type assistive device to measure the fingertip force. Calibration was performed for each finger joint angle because the variations in the expansion of the fingertip tissue depend on the joint angles. The root mean square error (RMSE) for fingertip force estimation ranged from 3.75% to 9.71% after calibration, regardless of the finger joint angles or finger posture.
format Online
Article
Text
id pubmed-6982706
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69827062020-02-28 A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices Park, Junghoon Heo, Pilwon Kim, Jung Na, Youngjin Sensors (Basel) Article This paper presents a fingertip grip force sensor based on custom capacitive sensors for glove-type assistive devices with an open-pad structure. The design of the sensor allows using human tactile sensations during grasping and manipulating an object. The proposed sensor can be attached on both sides of the fingertip and measure the force caused by the expansion of the fingertip tissue when a grasping force is applied to the fingertip. The number of measurable degrees of freedom (DoFs) are the two DoFs (flexion and adduction) for the thumb and one DoF (flexion) for the index and middle fingers. The proposed sensor allows the combination with a glove-type assistive device to measure the fingertip force. Calibration was performed for each finger joint angle because the variations in the expansion of the fingertip tissue depend on the joint angles. The root mean square error (RMSE) for fingertip force estimation ranged from 3.75% to 9.71% after calibration, regardless of the finger joint angles or finger posture. MDPI 2019-12-18 /pmc/articles/PMC6982706/ /pubmed/31861271 http://dx.doi.org/10.3390/s20010004 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Park, Junghoon
Heo, Pilwon
Kim, Jung
Na, Youngjin
A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices
title A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices
title_full A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices
title_fullStr A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices
title_full_unstemmed A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices
title_short A Finger Grip Force Sensor with an Open-Pad Structure for Glove-Type Assistive Devices
title_sort finger grip force sensor with an open-pad structure for glove-type assistive devices
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6982706/
https://www.ncbi.nlm.nih.gov/pubmed/31861271
http://dx.doi.org/10.3390/s20010004
work_keys_str_mv AT parkjunghoon afingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices
AT heopilwon afingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices
AT kimjung afingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices
AT nayoungjin afingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices
AT parkjunghoon fingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices
AT heopilwon fingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices
AT kimjung fingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices
AT nayoungjin fingergripforcesensorwithanopenpadstructureforglovetypeassistivedevices