Cargando…
A Non-Enzymatic Sensor Based on Trimetallic Nanoalloy with Poly (Diallyldimethylammonium Chloride)-Capped Reduced Graphene Oxide for Dynamic Monitoring Hydrogen Peroxide Production by Cancerous Cells
Catching cancer at an early stage is necessary to make it easier to treat and to save people’s lives rather than just extending them. Reactive oxygen species (ROS) have sparked a huge interest owing to their vital role in various biological processes, especially in tumorigenesis, thus leading to the...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6982804/ https://www.ncbi.nlm.nih.gov/pubmed/31877704 http://dx.doi.org/10.3390/s20010071 |
_version_ | 1783491373205291008 |
---|---|
author | Jiao, Jun Pan, Meixin Liu, Xinran Li, Binshuai Liu, Jian Chen, Qiang |
author_facet | Jiao, Jun Pan, Meixin Liu, Xinran Li, Binshuai Liu, Jian Chen, Qiang |
author_sort | Jiao, Jun |
collection | PubMed |
description | Catching cancer at an early stage is necessary to make it easier to treat and to save people’s lives rather than just extending them. Reactive oxygen species (ROS) have sparked a huge interest owing to their vital role in various biological processes, especially in tumorigenesis, thus leading to the potential of ROS as prognostic biomarkers for cancer. Herein, a non-enzymatic biosensor for the dynamic monitoring of intracellular hydrogen peroxide (H(2)O(2)), the most important ROS, via an effective electrode composed of poly (diallyldimethylammonium chloride) (PDDA)-capped reduced graphene oxide (RGO) nanosheets with high loading trimetallic AuPtAg nanoalloy, is proposed. The designed biosensor was able to measure H(2)O(2) released from different cancerous cells promptly and precisely owing to the impressive conductivity of RGO and PDDA and the excellent synergistic effect of the ternary alloy in boosting the electrocatalytic activity. Built upon the peroxidase-like activity of the nanoalloy, the developed sensor exhibited distinguished electrochemical performance, resulting in a low detection limit of 1.2 nM and a wide linear range from 0.05 μM to 5.5 mM. Our approach offers a significant contribution toward the further elucidation of the role of ROS in carcinogenesis and the effective screening of cancer at an early stage. |
format | Online Article Text |
id | pubmed-6982804 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-69828042020-02-06 A Non-Enzymatic Sensor Based on Trimetallic Nanoalloy with Poly (Diallyldimethylammonium Chloride)-Capped Reduced Graphene Oxide for Dynamic Monitoring Hydrogen Peroxide Production by Cancerous Cells Jiao, Jun Pan, Meixin Liu, Xinran Li, Binshuai Liu, Jian Chen, Qiang Sensors (Basel) Article Catching cancer at an early stage is necessary to make it easier to treat and to save people’s lives rather than just extending them. Reactive oxygen species (ROS) have sparked a huge interest owing to their vital role in various biological processes, especially in tumorigenesis, thus leading to the potential of ROS as prognostic biomarkers for cancer. Herein, a non-enzymatic biosensor for the dynamic monitoring of intracellular hydrogen peroxide (H(2)O(2)), the most important ROS, via an effective electrode composed of poly (diallyldimethylammonium chloride) (PDDA)-capped reduced graphene oxide (RGO) nanosheets with high loading trimetallic AuPtAg nanoalloy, is proposed. The designed biosensor was able to measure H(2)O(2) released from different cancerous cells promptly and precisely owing to the impressive conductivity of RGO and PDDA and the excellent synergistic effect of the ternary alloy in boosting the electrocatalytic activity. Built upon the peroxidase-like activity of the nanoalloy, the developed sensor exhibited distinguished electrochemical performance, resulting in a low detection limit of 1.2 nM and a wide linear range from 0.05 μM to 5.5 mM. Our approach offers a significant contribution toward the further elucidation of the role of ROS in carcinogenesis and the effective screening of cancer at an early stage. MDPI 2019-12-21 /pmc/articles/PMC6982804/ /pubmed/31877704 http://dx.doi.org/10.3390/s20010071 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jiao, Jun Pan, Meixin Liu, Xinran Li, Binshuai Liu, Jian Chen, Qiang A Non-Enzymatic Sensor Based on Trimetallic Nanoalloy with Poly (Diallyldimethylammonium Chloride)-Capped Reduced Graphene Oxide for Dynamic Monitoring Hydrogen Peroxide Production by Cancerous Cells |
title | A Non-Enzymatic Sensor Based on Trimetallic Nanoalloy with Poly (Diallyldimethylammonium Chloride)-Capped Reduced Graphene Oxide for Dynamic Monitoring Hydrogen Peroxide Production by Cancerous Cells |
title_full | A Non-Enzymatic Sensor Based on Trimetallic Nanoalloy with Poly (Diallyldimethylammonium Chloride)-Capped Reduced Graphene Oxide for Dynamic Monitoring Hydrogen Peroxide Production by Cancerous Cells |
title_fullStr | A Non-Enzymatic Sensor Based on Trimetallic Nanoalloy with Poly (Diallyldimethylammonium Chloride)-Capped Reduced Graphene Oxide for Dynamic Monitoring Hydrogen Peroxide Production by Cancerous Cells |
title_full_unstemmed | A Non-Enzymatic Sensor Based on Trimetallic Nanoalloy with Poly (Diallyldimethylammonium Chloride)-Capped Reduced Graphene Oxide for Dynamic Monitoring Hydrogen Peroxide Production by Cancerous Cells |
title_short | A Non-Enzymatic Sensor Based on Trimetallic Nanoalloy with Poly (Diallyldimethylammonium Chloride)-Capped Reduced Graphene Oxide for Dynamic Monitoring Hydrogen Peroxide Production by Cancerous Cells |
title_sort | non-enzymatic sensor based on trimetallic nanoalloy with poly (diallyldimethylammonium chloride)-capped reduced graphene oxide for dynamic monitoring hydrogen peroxide production by cancerous cells |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6982804/ https://www.ncbi.nlm.nih.gov/pubmed/31877704 http://dx.doi.org/10.3390/s20010071 |
work_keys_str_mv | AT jiaojun anonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT panmeixin anonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT liuxinran anonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT libinshuai anonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT liujian anonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT chenqiang anonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT jiaojun nonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT panmeixin nonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT liuxinran nonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT libinshuai nonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT liujian nonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells AT chenqiang nonenzymaticsensorbasedontrimetallicnanoalloywithpolydiallyldimethylammoniumchloridecappedreducedgrapheneoxidefordynamicmonitoringhydrogenperoxideproductionbycancerouscells |