Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure

Non-enzymatic glucose sensing is a crucial field of study because of the current market demand. This study proposes a novel design of glucose sensor with enhanced selectivity and sensitivity by using graphene Schottky diodes, which is composed of graphene (G)/platinum oxide (PtO)/n-silicon (Si) hete...

Descripción completa

Detalles Bibliográficos
Autores principales: Sakr, Mahmoud A., Elgammal, Karim, Delin, Anna, Serry, Mohamed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6982948/
https://www.ncbi.nlm.nih.gov/pubmed/31878328
http://dx.doi.org/10.3390/s20010145
_version_ 1783491406619213824
author Sakr, Mahmoud A.
Elgammal, Karim
Delin, Anna
Serry, Mohamed
author_facet Sakr, Mahmoud A.
Elgammal, Karim
Delin, Anna
Serry, Mohamed
author_sort Sakr, Mahmoud A.
collection PubMed
description Non-enzymatic glucose sensing is a crucial field of study because of the current market demand. This study proposes a novel design of glucose sensor with enhanced selectivity and sensitivity by using graphene Schottky diodes, which is composed of graphene (G)/platinum oxide (PtO)/n-silicon (Si) heterostructure. The sensor was tested with different glucose concentrations and interfering solutions to investigate its sensitivity and selectivity. Different structures of the device were studied by adjusting the platinum oxide film thickness to investigate its catalytic activity. It was found that the film thickness plays a significant role in the efficiency of glucose oxidation and hence in overall device sensitivity. 0.8–2 μA output current was obtained in the case of 4–10 mM with a sensitivity of 0.2 μA/mM.cm(2). Besides, results have shown that 0.8 μA and 15 μA were obtained by testing 4 mM glucose on two different PtO thicknesses, 30 nm and 50 nm, respectively. The sensitivity of the device was enhanced by 150% (i.e., up to 30 μA/mM.cm(2)) by increasing the PtO layer thickness. This was attributed to both the increase of the number of active sites for glucose oxidation as well as the increase in the graphene layer thickness, which leads to enhanced charge carriers concentration and mobility. Moreover, theoretical investigations were conducted using the density function theory (DFT) to understand the detection method and the origins of selectivity better. The working principle of the sensors puts it in a competitive position with other non-enzymatic glucose sensors. DFT calculations provided a qualitative explanation of the charge distribution across the graphene sheet within a system of a platinum substrate with D-glucose molecules above. The proposed G/PtO/n-Si heterostructure has proven to satisfy these factors, which opens the door for further developments of more reliable non-enzymatic glucometers for continuous glucose monitoring systems.
format Online
Article
Text
id pubmed-6982948
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-69829482020-02-06 Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure Sakr, Mahmoud A. Elgammal, Karim Delin, Anna Serry, Mohamed Sensors (Basel) Article Non-enzymatic glucose sensing is a crucial field of study because of the current market demand. This study proposes a novel design of glucose sensor with enhanced selectivity and sensitivity by using graphene Schottky diodes, which is composed of graphene (G)/platinum oxide (PtO)/n-silicon (Si) heterostructure. The sensor was tested with different glucose concentrations and interfering solutions to investigate its sensitivity and selectivity. Different structures of the device were studied by adjusting the platinum oxide film thickness to investigate its catalytic activity. It was found that the film thickness plays a significant role in the efficiency of glucose oxidation and hence in overall device sensitivity. 0.8–2 μA output current was obtained in the case of 4–10 mM with a sensitivity of 0.2 μA/mM.cm(2). Besides, results have shown that 0.8 μA and 15 μA were obtained by testing 4 mM glucose on two different PtO thicknesses, 30 nm and 50 nm, respectively. The sensitivity of the device was enhanced by 150% (i.e., up to 30 μA/mM.cm(2)) by increasing the PtO layer thickness. This was attributed to both the increase of the number of active sites for glucose oxidation as well as the increase in the graphene layer thickness, which leads to enhanced charge carriers concentration and mobility. Moreover, theoretical investigations were conducted using the density function theory (DFT) to understand the detection method and the origins of selectivity better. The working principle of the sensors puts it in a competitive position with other non-enzymatic glucose sensors. DFT calculations provided a qualitative explanation of the charge distribution across the graphene sheet within a system of a platinum substrate with D-glucose molecules above. The proposed G/PtO/n-Si heterostructure has proven to satisfy these factors, which opens the door for further developments of more reliable non-enzymatic glucometers for continuous glucose monitoring systems. MDPI 2019-12-24 /pmc/articles/PMC6982948/ /pubmed/31878328 http://dx.doi.org/10.3390/s20010145 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sakr, Mahmoud A.
Elgammal, Karim
Delin, Anna
Serry, Mohamed
Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure
title Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure
title_full Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure
title_fullStr Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure
title_full_unstemmed Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure
title_short Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure
title_sort performance-enhanced non-enzymatic glucose sensor based on graphene-heterostructure
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6982948/
https://www.ncbi.nlm.nih.gov/pubmed/31878328
http://dx.doi.org/10.3390/s20010145
work_keys_str_mv AT sakrmahmouda performanceenhancednonenzymaticglucosesensorbasedongrapheneheterostructure
AT elgammalkarim performanceenhancednonenzymaticglucosesensorbasedongrapheneheterostructure
AT delinanna performanceenhancednonenzymaticglucosesensorbasedongrapheneheterostructure
AT serrymohamed performanceenhancednonenzymaticglucosesensorbasedongrapheneheterostructure