Cargando…
Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
INTRODUCTION: Pulse pressure variation (PPV) has been shown to be useful to predict fluid responsiveness in patients ventilated at tidal volume (Vt) >8 mL kg(−1). Nevertheless, most conditions in critical care force to use lower Vt. Thus, we sought to evaluate the operative performance of PPV whe...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6984427/ https://www.ncbi.nlm.nih.gov/pubmed/32047358 http://dx.doi.org/10.1177/1179548420901518 |
_version_ | 1783491650072346624 |
---|---|
author | Alvarado Sánchez, Jorge Iván Caicedo Ruiz, Juan Daniel Diaztagle Fernández, Juan José Ospina-Tascón, Gustavo Adolfo Cruz Martínez, Luis Eduardo |
author_facet | Alvarado Sánchez, Jorge Iván Caicedo Ruiz, Juan Daniel Diaztagle Fernández, Juan José Ospina-Tascón, Gustavo Adolfo Cruz Martínez, Luis Eduardo |
author_sort | Alvarado Sánchez, Jorge Iván |
collection | PubMed |
description | INTRODUCTION: Pulse pressure variation (PPV) has been shown to be useful to predict fluid responsiveness in patients ventilated at tidal volume (Vt) >8 mL kg(−1). Nevertheless, most conditions in critical care force to use lower Vt. Thus, we sought to evaluate the operative performance of PPV when a Vt ⩽8 mL kg(−1) is used during mechanical ventilation support. METHODS: We searched PubMed and Embase databases for articles evaluating the operative performance of PPV as a predictor of fluid responsiveness in critical care and perioperative adult patients ventilated with tidal volume ⩽8 mL kg(−1) without respiratory effort and arrhythmias, between January 1990 and January 2019. We included cohort and cross-sectional studies. Two authors performed an Independently selection using predefined terms of search. The fitted data of sensitivity, specificity, and area under the curve (AUC) were assessed by bivariate and hierarchical analyses. RESULTS: We retrieved 19 trials with a total of 777 patients and a total of 935 fluid challenges. The fitted sensitivity of PPV to predict fluid responsiveness during mechanical ventilation at Vt ⩽8 mL kg(−1) was 0.65 (95% confidence interval [CI]: 0.57-0.73), the specificity was 0.79 (95% CI: 0.73-0.84), and the AUC was 0.75. The diagnostic odds ratio was 5.5 (95% CI: 3.08-10.01, P < .001) by the random-effects model. CONCLUSIONS: Pulse pressure variation shows a fair operative performance as a predictor of fluid responsiveness in critical care and perioperative patients ventilated with a tidal volume ⩽8 mL kg(−1) without respiratory effort and arrhythmias. |
format | Online Article Text |
id | pubmed-6984427 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-69844272020-02-11 Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis Alvarado Sánchez, Jorge Iván Caicedo Ruiz, Juan Daniel Diaztagle Fernández, Juan José Ospina-Tascón, Gustavo Adolfo Cruz Martínez, Luis Eduardo Clin Med Insights Circ Respir Pulm Med Meta-Analysis INTRODUCTION: Pulse pressure variation (PPV) has been shown to be useful to predict fluid responsiveness in patients ventilated at tidal volume (Vt) >8 mL kg(−1). Nevertheless, most conditions in critical care force to use lower Vt. Thus, we sought to evaluate the operative performance of PPV when a Vt ⩽8 mL kg(−1) is used during mechanical ventilation support. METHODS: We searched PubMed and Embase databases for articles evaluating the operative performance of PPV as a predictor of fluid responsiveness in critical care and perioperative adult patients ventilated with tidal volume ⩽8 mL kg(−1) without respiratory effort and arrhythmias, between January 1990 and January 2019. We included cohort and cross-sectional studies. Two authors performed an Independently selection using predefined terms of search. The fitted data of sensitivity, specificity, and area under the curve (AUC) were assessed by bivariate and hierarchical analyses. RESULTS: We retrieved 19 trials with a total of 777 patients and a total of 935 fluid challenges. The fitted sensitivity of PPV to predict fluid responsiveness during mechanical ventilation at Vt ⩽8 mL kg(−1) was 0.65 (95% confidence interval [CI]: 0.57-0.73), the specificity was 0.79 (95% CI: 0.73-0.84), and the AUC was 0.75. The diagnostic odds ratio was 5.5 (95% CI: 3.08-10.01, P < .001) by the random-effects model. CONCLUSIONS: Pulse pressure variation shows a fair operative performance as a predictor of fluid responsiveness in critical care and perioperative patients ventilated with a tidal volume ⩽8 mL kg(−1) without respiratory effort and arrhythmias. SAGE Publications 2020-01-24 /pmc/articles/PMC6984427/ /pubmed/32047358 http://dx.doi.org/10.1177/1179548420901518 Text en © The Author(s) 2020 https://www.creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Meta-Analysis Alvarado Sánchez, Jorge Iván Caicedo Ruiz, Juan Daniel Diaztagle Fernández, Juan José Ospina-Tascón, Gustavo Adolfo Cruz Martínez, Luis Eduardo Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis |
title | Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis |
title_full | Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis |
title_fullStr | Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis |
title_short | Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis |
title_sort | use of pulse pressure variation as predictor of fluid responsiveness in patients ventilated with low tidal volume: a systematic review and meta-analysis |
topic | Meta-Analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6984427/ https://www.ncbi.nlm.nih.gov/pubmed/32047358 http://dx.doi.org/10.1177/1179548420901518 |
work_keys_str_mv | AT alvaradosanchezjorgeivan useofpulsepressurevariationaspredictoroffluidresponsivenessinpatientsventilatedwithlowtidalvolumeasystematicreviewandmetaanalysis AT caicedoruizjuandaniel useofpulsepressurevariationaspredictoroffluidresponsivenessinpatientsventilatedwithlowtidalvolumeasystematicreviewandmetaanalysis AT diaztaglefernandezjuanjose useofpulsepressurevariationaspredictoroffluidresponsivenessinpatientsventilatedwithlowtidalvolumeasystematicreviewandmetaanalysis AT ospinatascongustavoadolfo useofpulsepressurevariationaspredictoroffluidresponsivenessinpatientsventilatedwithlowtidalvolumeasystematicreviewandmetaanalysis AT cruzmartinezluiseduardo useofpulsepressurevariationaspredictoroffluidresponsivenessinpatientsventilatedwithlowtidalvolumeasystematicreviewandmetaanalysis |