Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis

INTRODUCTION: Pulse pressure variation (PPV) has been shown to be useful to predict fluid responsiveness in patients ventilated at tidal volume (Vt) >8 mL kg(−1). Nevertheless, most conditions in critical care force to use lower Vt. Thus, we sought to evaluate the operative performance of PPV whe...

Descripción completa

Detalles Bibliográficos
Autores principales: Alvarado Sánchez, Jorge Iván, Caicedo Ruiz, Juan Daniel, Diaztagle Fernández, Juan José, Ospina-Tascón, Gustavo Adolfo, Cruz Martínez, Luis Eduardo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6984427/
https://www.ncbi.nlm.nih.gov/pubmed/32047358
http://dx.doi.org/10.1177/1179548420901518
_version_ 1783491650072346624
author Alvarado Sánchez, Jorge Iván
Caicedo Ruiz, Juan Daniel
Diaztagle Fernández, Juan José
Ospina-Tascón, Gustavo Adolfo
Cruz Martínez, Luis Eduardo
author_facet Alvarado Sánchez, Jorge Iván
Caicedo Ruiz, Juan Daniel
Diaztagle Fernández, Juan José
Ospina-Tascón, Gustavo Adolfo
Cruz Martínez, Luis Eduardo
author_sort Alvarado Sánchez, Jorge Iván
collection PubMed
description INTRODUCTION: Pulse pressure variation (PPV) has been shown to be useful to predict fluid responsiveness in patients ventilated at tidal volume (Vt) >8 mL kg(−1). Nevertheless, most conditions in critical care force to use lower Vt. Thus, we sought to evaluate the operative performance of PPV when a Vt ⩽8 mL kg(−1) is used during mechanical ventilation support. METHODS: We searched PubMed and Embase databases for articles evaluating the operative performance of PPV as a predictor of fluid responsiveness in critical care and perioperative adult patients ventilated with tidal volume ⩽8 mL kg(−1) without respiratory effort and arrhythmias, between January 1990 and January 2019. We included cohort and cross-sectional studies. Two authors performed an Independently selection using predefined terms of search. The fitted data of sensitivity, specificity, and area under the curve (AUC) were assessed by bivariate and hierarchical analyses. RESULTS: We retrieved 19 trials with a total of 777 patients and a total of 935 fluid challenges. The fitted sensitivity of PPV to predict fluid responsiveness during mechanical ventilation at Vt ⩽8 mL kg(−1) was 0.65 (95% confidence interval [CI]: 0.57-0.73), the specificity was 0.79 (95% CI: 0.73-0.84), and the AUC was 0.75. The diagnostic odds ratio was 5.5 (95% CI: 3.08-10.01, P < .001) by the random-effects model. CONCLUSIONS: Pulse pressure variation shows a fair operative performance as a predictor of fluid responsiveness in critical care and perioperative patients ventilated with a tidal volume ⩽8 mL kg(−1) without respiratory effort and arrhythmias.
format Online
Article
Text
id pubmed-6984427
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-69844272020-02-11 Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis Alvarado Sánchez, Jorge Iván Caicedo Ruiz, Juan Daniel Diaztagle Fernández, Juan José Ospina-Tascón, Gustavo Adolfo Cruz Martínez, Luis Eduardo Clin Med Insights Circ Respir Pulm Med Meta-Analysis INTRODUCTION: Pulse pressure variation (PPV) has been shown to be useful to predict fluid responsiveness in patients ventilated at tidal volume (Vt) >8 mL kg(−1). Nevertheless, most conditions in critical care force to use lower Vt. Thus, we sought to evaluate the operative performance of PPV when a Vt ⩽8 mL kg(−1) is used during mechanical ventilation support. METHODS: We searched PubMed and Embase databases for articles evaluating the operative performance of PPV as a predictor of fluid responsiveness in critical care and perioperative adult patients ventilated with tidal volume ⩽8 mL kg(−1) without respiratory effort and arrhythmias, between January 1990 and January 2019. We included cohort and cross-sectional studies. Two authors performed an Independently selection using predefined terms of search. The fitted data of sensitivity, specificity, and area under the curve (AUC) were assessed by bivariate and hierarchical analyses. RESULTS: We retrieved 19 trials with a total of 777 patients and a total of 935 fluid challenges. The fitted sensitivity of PPV to predict fluid responsiveness during mechanical ventilation at Vt ⩽8 mL kg(−1) was 0.65 (95% confidence interval [CI]: 0.57-0.73), the specificity was 0.79 (95% CI: 0.73-0.84), and the AUC was 0.75. The diagnostic odds ratio was 5.5 (95% CI: 3.08-10.01, P < .001) by the random-effects model. CONCLUSIONS: Pulse pressure variation shows a fair operative performance as a predictor of fluid responsiveness in critical care and perioperative patients ventilated with a tidal volume ⩽8 mL kg(−1) without respiratory effort and arrhythmias. SAGE Publications 2020-01-24 /pmc/articles/PMC6984427/ /pubmed/32047358 http://dx.doi.org/10.1177/1179548420901518 Text en © The Author(s) 2020 https://www.creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Meta-Analysis
Alvarado Sánchez, Jorge Iván
Caicedo Ruiz, Juan Daniel
Diaztagle Fernández, Juan José
Ospina-Tascón, Gustavo Adolfo
Cruz Martínez, Luis Eduardo
Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
title Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
title_full Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
title_fullStr Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
title_full_unstemmed Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
title_short Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
title_sort use of pulse pressure variation as predictor of fluid responsiveness in patients ventilated with low tidal volume: a systematic review and meta-analysis
topic Meta-Analysis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6984427/
https://www.ncbi.nlm.nih.gov/pubmed/32047358
http://dx.doi.org/10.1177/1179548420901518
work_keys_str_mv AT alvaradosanchezjorgeivan useofpulsepressurevariationaspredictoroffluidresponsivenessinpatientsventilatedwithlowtidalvolumeasystematicreviewandmetaanalysis
AT caicedoruizjuandaniel useofpulsepressurevariationaspredictoroffluidresponsivenessinpatientsventilatedwithlowtidalvolumeasystematicreviewandmetaanalysis
AT diaztaglefernandezjuanjose useofpulsepressurevariationaspredictoroffluidresponsivenessinpatientsventilatedwithlowtidalvolumeasystematicreviewandmetaanalysis
AT ospinatascongustavoadolfo useofpulsepressurevariationaspredictoroffluidresponsivenessinpatientsventilatedwithlowtidalvolumeasystematicreviewandmetaanalysis
AT cruzmartinezluiseduardo useofpulsepressurevariationaspredictoroffluidresponsivenessinpatientsventilatedwithlowtidalvolumeasystematicreviewandmetaanalysis