Cargando…
Effect of voicing and articulation manner on aerosol particle emission during human speech
Previously, we demonstrated a strong correlation between the amplitude of human speech and the emission rate of micron-scale expiratory aerosol particles, which are believed to play a role in respiratory disease transmission. To further those findings, here we systematically investigate the effect o...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6984704/ https://www.ncbi.nlm.nih.gov/pubmed/31986165 http://dx.doi.org/10.1371/journal.pone.0227699 |
_version_ | 1783491679297208320 |
---|---|
author | Asadi, Sima Wexler, Anthony S. Cappa, Christopher D. Barreda, Santiago Bouvier, Nicole M. Ristenpart, William D. |
author_facet | Asadi, Sima Wexler, Anthony S. Cappa, Christopher D. Barreda, Santiago Bouvier, Nicole M. Ristenpart, William D. |
author_sort | Asadi, Sima |
collection | PubMed |
description | Previously, we demonstrated a strong correlation between the amplitude of human speech and the emission rate of micron-scale expiratory aerosol particles, which are believed to play a role in respiratory disease transmission. To further those findings, here we systematically investigate the effect of different ‘phones’ (the basic sound units of speech) on the emission of particles from the human respiratory tract during speech. We measured the respiratory particle emission rates of 56 healthy human volunteers voicing specific phones, both in isolation and in the context of a standard spoken text. We found that certain phones are associated with significantly higher particle production; for example, the vowel /i/ (“need,” “sea”) produces more particles than /ɑ/ (“saw,” “hot”) or /u/ (“blue,” “mood”), while disyllabic words including voiced plosive consonants (e.g., /d/, /b/, /g/) yield more particles than words with voiceless fricatives (e.g., /s/, /h/, /f/). These trends for discrete phones and words were corroborated by the time-resolved particle emission rates as volunteers read aloud from a standard text passage that incorporates a broad range of the phones present in spoken English. Our measurements showed that particle emission rates were positively correlated with the vowel content of a phrase; conversely, particle emission decreased during phrases with a high fraction of voiceless fricatives. Our particle emission data is broadly consistent with prior measurements of the egressive airflow rate associated with the vocalization of various phones that differ in voicing and articulation. These results suggest that airborne transmission of respiratory pathogens via speech aerosol particles could be modulated by specific phonetic characteristics of the language spoken by a given human population, along with other, more frequently considered epidemiological variables. |
format | Online Article Text |
id | pubmed-6984704 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-69847042020-02-07 Effect of voicing and articulation manner on aerosol particle emission during human speech Asadi, Sima Wexler, Anthony S. Cappa, Christopher D. Barreda, Santiago Bouvier, Nicole M. Ristenpart, William D. PLoS One Research Article Previously, we demonstrated a strong correlation between the amplitude of human speech and the emission rate of micron-scale expiratory aerosol particles, which are believed to play a role in respiratory disease transmission. To further those findings, here we systematically investigate the effect of different ‘phones’ (the basic sound units of speech) on the emission of particles from the human respiratory tract during speech. We measured the respiratory particle emission rates of 56 healthy human volunteers voicing specific phones, both in isolation and in the context of a standard spoken text. We found that certain phones are associated with significantly higher particle production; for example, the vowel /i/ (“need,” “sea”) produces more particles than /ɑ/ (“saw,” “hot”) or /u/ (“blue,” “mood”), while disyllabic words including voiced plosive consonants (e.g., /d/, /b/, /g/) yield more particles than words with voiceless fricatives (e.g., /s/, /h/, /f/). These trends for discrete phones and words were corroborated by the time-resolved particle emission rates as volunteers read aloud from a standard text passage that incorporates a broad range of the phones present in spoken English. Our measurements showed that particle emission rates were positively correlated with the vowel content of a phrase; conversely, particle emission decreased during phrases with a high fraction of voiceless fricatives. Our particle emission data is broadly consistent with prior measurements of the egressive airflow rate associated with the vocalization of various phones that differ in voicing and articulation. These results suggest that airborne transmission of respiratory pathogens via speech aerosol particles could be modulated by specific phonetic characteristics of the language spoken by a given human population, along with other, more frequently considered epidemiological variables. Public Library of Science 2020-01-27 /pmc/articles/PMC6984704/ /pubmed/31986165 http://dx.doi.org/10.1371/journal.pone.0227699 Text en © 2020 Asadi et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Asadi, Sima Wexler, Anthony S. Cappa, Christopher D. Barreda, Santiago Bouvier, Nicole M. Ristenpart, William D. Effect of voicing and articulation manner on aerosol particle emission during human speech |
title | Effect of voicing and articulation manner on aerosol particle emission during human speech |
title_full | Effect of voicing and articulation manner on aerosol particle emission during human speech |
title_fullStr | Effect of voicing and articulation manner on aerosol particle emission during human speech |
title_full_unstemmed | Effect of voicing and articulation manner on aerosol particle emission during human speech |
title_short | Effect of voicing and articulation manner on aerosol particle emission during human speech |
title_sort | effect of voicing and articulation manner on aerosol particle emission during human speech |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6984704/ https://www.ncbi.nlm.nih.gov/pubmed/31986165 http://dx.doi.org/10.1371/journal.pone.0227699 |
work_keys_str_mv | AT asadisima effectofvoicingandarticulationmanneronaerosolparticleemissionduringhumanspeech AT wexleranthonys effectofvoicingandarticulationmanneronaerosolparticleemissionduringhumanspeech AT cappachristopherd effectofvoicingandarticulationmanneronaerosolparticleemissionduringhumanspeech AT barredasantiago effectofvoicingandarticulationmanneronaerosolparticleemissionduringhumanspeech AT bouviernicolem effectofvoicingandarticulationmanneronaerosolparticleemissionduringhumanspeech AT ristenpartwilliamd effectofvoicingandarticulationmanneronaerosolparticleemissionduringhumanspeech |