Cargando…

Diffuse reflectance spectroscopy, a potential optical sensing technology for the detection of cortical breaches during spinal screw placement

Safe and accurate placement of screws remains a critical issue in open and minimally invasive spine surgery. We propose to use diffuse reflectance (DR) spectroscopy as a sensing technology at the tip of a surgical instrument to ensure a safe path of the instrument through the cancellous bone of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Swamy, Akash, Burström, Gustav, Spliethoff, Jarich W., Babic, Drazenko, Reich, Christian, Groen, Joanneke, Edström, Erik, Elmi Terander, Adrian, Racadio, John M., Dankelman, Jenny, Hendriks, Benno H. W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6985697/
https://www.ncbi.nlm.nih.gov/pubmed/30701722
http://dx.doi.org/10.1117/1.JBO.24.1.017002
_version_ 1783491860069613568
author Swamy, Akash
Burström, Gustav
Spliethoff, Jarich W.
Babic, Drazenko
Reich, Christian
Groen, Joanneke
Edström, Erik
Elmi Terander, Adrian
Racadio, John M.
Dankelman, Jenny
Hendriks, Benno H. W.
author_facet Swamy, Akash
Burström, Gustav
Spliethoff, Jarich W.
Babic, Drazenko
Reich, Christian
Groen, Joanneke
Edström, Erik
Elmi Terander, Adrian
Racadio, John M.
Dankelman, Jenny
Hendriks, Benno H. W.
author_sort Swamy, Akash
collection PubMed
description Safe and accurate placement of screws remains a critical issue in open and minimally invasive spine surgery. We propose to use diffuse reflectance (DR) spectroscopy as a sensing technology at the tip of a surgical instrument to ensure a safe path of the instrument through the cancellous bone of the vertebrae. This approach could potentially reduce the rate of cortical bone breaches, thereby resulting in fewer neural and vascular injuries during spinal fusion surgery. In our study, DR spectra in the wavelength ranges of 400 to 1600 nm were acquired from cancellous and cortical bone from three human cadavers. First, it was investigated whether these spectra can be used to distinguish between the two bone types based on fat, water, and blood content along with photon scattering. Subsequently, the penetration of the bone by an optical probe was simulated using the Monte-Carlo (MC) method, to study if the changes in fat content along the probe path would still enable distinction between the bone types. Finally, the simulation findings were validated via an experimental insertion of an optical screw probe into the vertebra aided by x-ray image guidance. The DR spectra indicate that the amount of fat, blood, and photon scattering is significantly higher in cancellous bone than in cortical bone ([Formula: see text]), which allows distinction between the bone types. The MC simulations showed a change in fat content more than 1 mm before the optical probe came in contact with the cortical bone. The experimental insertion of the optical screw probe gave similar results. This study shows that spectral tissue sensing, based on DR spectroscopy at the instrument tip, is a promising technology to identify the transition zone from cancellous to cortical vertebral bone. The technology therefore has the potential to improve the safety and accuracy of spinal screw placement procedures.
format Online
Article
Text
id pubmed-6985697
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-69856972020-02-03 Diffuse reflectance spectroscopy, a potential optical sensing technology for the detection of cortical breaches during spinal screw placement Swamy, Akash Burström, Gustav Spliethoff, Jarich W. Babic, Drazenko Reich, Christian Groen, Joanneke Edström, Erik Elmi Terander, Adrian Racadio, John M. Dankelman, Jenny Hendriks, Benno H. W. J Biomed Opt Sensing Safe and accurate placement of screws remains a critical issue in open and minimally invasive spine surgery. We propose to use diffuse reflectance (DR) spectroscopy as a sensing technology at the tip of a surgical instrument to ensure a safe path of the instrument through the cancellous bone of the vertebrae. This approach could potentially reduce the rate of cortical bone breaches, thereby resulting in fewer neural and vascular injuries during spinal fusion surgery. In our study, DR spectra in the wavelength ranges of 400 to 1600 nm were acquired from cancellous and cortical bone from three human cadavers. First, it was investigated whether these spectra can be used to distinguish between the two bone types based on fat, water, and blood content along with photon scattering. Subsequently, the penetration of the bone by an optical probe was simulated using the Monte-Carlo (MC) method, to study if the changes in fat content along the probe path would still enable distinction between the bone types. Finally, the simulation findings were validated via an experimental insertion of an optical screw probe into the vertebra aided by x-ray image guidance. The DR spectra indicate that the amount of fat, blood, and photon scattering is significantly higher in cancellous bone than in cortical bone ([Formula: see text]), which allows distinction between the bone types. The MC simulations showed a change in fat content more than 1 mm before the optical probe came in contact with the cortical bone. The experimental insertion of the optical screw probe gave similar results. This study shows that spectral tissue sensing, based on DR spectroscopy at the instrument tip, is a promising technology to identify the transition zone from cancellous to cortical vertebral bone. The technology therefore has the potential to improve the safety and accuracy of spinal screw placement procedures. Society of Photo-Optical Instrumentation Engineers 2019-01-30 2019-01 /pmc/articles/PMC6985697/ /pubmed/30701722 http://dx.doi.org/10.1117/1.JBO.24.1.017002 Text en © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Sensing
Swamy, Akash
Burström, Gustav
Spliethoff, Jarich W.
Babic, Drazenko
Reich, Christian
Groen, Joanneke
Edström, Erik
Elmi Terander, Adrian
Racadio, John M.
Dankelman, Jenny
Hendriks, Benno H. W.
Diffuse reflectance spectroscopy, a potential optical sensing technology for the detection of cortical breaches during spinal screw placement
title Diffuse reflectance spectroscopy, a potential optical sensing technology for the detection of cortical breaches during spinal screw placement
title_full Diffuse reflectance spectroscopy, a potential optical sensing technology for the detection of cortical breaches during spinal screw placement
title_fullStr Diffuse reflectance spectroscopy, a potential optical sensing technology for the detection of cortical breaches during spinal screw placement
title_full_unstemmed Diffuse reflectance spectroscopy, a potential optical sensing technology for the detection of cortical breaches during spinal screw placement
title_short Diffuse reflectance spectroscopy, a potential optical sensing technology for the detection of cortical breaches during spinal screw placement
title_sort diffuse reflectance spectroscopy, a potential optical sensing technology for the detection of cortical breaches during spinal screw placement
topic Sensing
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6985697/
https://www.ncbi.nlm.nih.gov/pubmed/30701722
http://dx.doi.org/10.1117/1.JBO.24.1.017002
work_keys_str_mv AT swamyakash diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement
AT burstromgustav diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement
AT spliethoffjarichw diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement
AT babicdrazenko diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement
AT reichchristian diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement
AT groenjoanneke diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement
AT edstromerik diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement
AT elmiteranderadrian diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement
AT racadiojohnm diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement
AT dankelmanjenny diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement
AT hendriksbennohw diffusereflectancespectroscopyapotentialopticalsensingtechnologyforthedetectionofcorticalbreachesduringspinalscrewplacement