Cargando…

Task shifting for point-of-care early infant diagnosis: a comparison of the quality of testing between nurses and laboratory personnel in Zimbabwe

BACKGROUND: To decentralize point-of-care early infant diagnosis (POC EID), task shifting to cadres such as nurses is important. However, this should not compromise quality of testing through generating high rates of internal quality control (IQC) failures and long result turnaround times. We used d...

Descripción completa

Detalles Bibliográficos
Autores principales: Simmonds, Francis M., Cohn, Jennifer E., Mafaune, Haurovi W., Nyamundaya, Tichaona H., Mahomva, Agnes, Chadambuka, Addmore
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6986104/
https://www.ncbi.nlm.nih.gov/pubmed/31992332
http://dx.doi.org/10.1186/s12960-020-0449-2
_version_ 1783491917018824704
author Simmonds, Francis M.
Cohn, Jennifer E.
Mafaune, Haurovi W.
Nyamundaya, Tichaona H.
Mahomva, Agnes
Chadambuka, Addmore
author_facet Simmonds, Francis M.
Cohn, Jennifer E.
Mafaune, Haurovi W.
Nyamundaya, Tichaona H.
Mahomva, Agnes
Chadambuka, Addmore
author_sort Simmonds, Francis M.
collection PubMed
description BACKGROUND: To decentralize point-of-care early infant diagnosis (POC EID), task shifting to cadres such as nurses is important. However, this should not compromise quality of testing through generating high rates of internal quality control (IQC) failures and long result turnaround times. We used data from a POC EID project in Zimbabwe to compare IQC rates and result return to caregivers for samples run on a POC EID technology (Alere q HIV 1/2 Detect) between nurses and laboratory-trained personnel to assess effects of task shifting on quality of testing. METHODS: This cross-sectional retrospective study used data from all 46 sites (10 hub and 36 spoke sites in Zimbabwe that piloted POC EID for routine clinical use from December 2016 to June 2017). IQC failure rates were downloaded from each POC EID platform and exported to excel to analyze IQC failure rates by type of operator. Turnaround time (TAT) from sample collection to issuing of results to caregiver was extracted from the EID test request form and uploaded into a project specific Excel-based database for analysis. RESULTS: A total of 1847 tests were conducted by 45 testers (12 laboratory-trained and 33 non-laboratory-trained personnel), including 165 errors. There were no significant differences in IQC failure rates between non-laboratory testers (137 [9.2%] of 14830 tests) and specialized laboratory-trained (28 [7.7%] of 364 tests; p = 0.354). Over time, IQC failure rates for both non-laboratory (χ(2) = 18.5, p < 0.000) and specialized laboratory-trained testers (χ(2) = 8.7, p < 0.003) decreased significantly. There were similar proportions of clients who were issued with results between samples processed by non-laboratory testers (1283 [98.9%] of 1297 tests) and samples processed by specialized laboratory-trained testers (315 [98.7%] of 319 tests; p = 0.790). The overall median turnaround time from sample collection to receipt of results by caregiver for samples run by laboratory-specialized testers was not statistically different from samples run by non-laboratory-specialized testers (1 day [IQR 0–3] versus 0 days [IQR 0–2]; p = 0.583). CONCLUSIONS: Similar IQC failure rates and TATs between non-laboratory and specialized laboratory-trained operators suggest that non-specialized laboratory-trained personnel can perform POC EID equally well as specialized laboratory personnel.
format Online
Article
Text
id pubmed-6986104
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-69861042020-01-30 Task shifting for point-of-care early infant diagnosis: a comparison of the quality of testing between nurses and laboratory personnel in Zimbabwe Simmonds, Francis M. Cohn, Jennifer E. Mafaune, Haurovi W. Nyamundaya, Tichaona H. Mahomva, Agnes Chadambuka, Addmore Hum Resour Health Research BACKGROUND: To decentralize point-of-care early infant diagnosis (POC EID), task shifting to cadres such as nurses is important. However, this should not compromise quality of testing through generating high rates of internal quality control (IQC) failures and long result turnaround times. We used data from a POC EID project in Zimbabwe to compare IQC rates and result return to caregivers for samples run on a POC EID technology (Alere q HIV 1/2 Detect) between nurses and laboratory-trained personnel to assess effects of task shifting on quality of testing. METHODS: This cross-sectional retrospective study used data from all 46 sites (10 hub and 36 spoke sites in Zimbabwe that piloted POC EID for routine clinical use from December 2016 to June 2017). IQC failure rates were downloaded from each POC EID platform and exported to excel to analyze IQC failure rates by type of operator. Turnaround time (TAT) from sample collection to issuing of results to caregiver was extracted from the EID test request form and uploaded into a project specific Excel-based database for analysis. RESULTS: A total of 1847 tests were conducted by 45 testers (12 laboratory-trained and 33 non-laboratory-trained personnel), including 165 errors. There were no significant differences in IQC failure rates between non-laboratory testers (137 [9.2%] of 14830 tests) and specialized laboratory-trained (28 [7.7%] of 364 tests; p = 0.354). Over time, IQC failure rates for both non-laboratory (χ(2) = 18.5, p < 0.000) and specialized laboratory-trained testers (χ(2) = 8.7, p < 0.003) decreased significantly. There were similar proportions of clients who were issued with results between samples processed by non-laboratory testers (1283 [98.9%] of 1297 tests) and samples processed by specialized laboratory-trained testers (315 [98.7%] of 319 tests; p = 0.790). The overall median turnaround time from sample collection to receipt of results by caregiver for samples run by laboratory-specialized testers was not statistically different from samples run by non-laboratory-specialized testers (1 day [IQR 0–3] versus 0 days [IQR 0–2]; p = 0.583). CONCLUSIONS: Similar IQC failure rates and TATs between non-laboratory and specialized laboratory-trained operators suggest that non-specialized laboratory-trained personnel can perform POC EID equally well as specialized laboratory personnel. BioMed Central 2020-01-28 /pmc/articles/PMC6986104/ /pubmed/31992332 http://dx.doi.org/10.1186/s12960-020-0449-2 Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Simmonds, Francis M.
Cohn, Jennifer E.
Mafaune, Haurovi W.
Nyamundaya, Tichaona H.
Mahomva, Agnes
Chadambuka, Addmore
Task shifting for point-of-care early infant diagnosis: a comparison of the quality of testing between nurses and laboratory personnel in Zimbabwe
title Task shifting for point-of-care early infant diagnosis: a comparison of the quality of testing between nurses and laboratory personnel in Zimbabwe
title_full Task shifting for point-of-care early infant diagnosis: a comparison of the quality of testing between nurses and laboratory personnel in Zimbabwe
title_fullStr Task shifting for point-of-care early infant diagnosis: a comparison of the quality of testing between nurses and laboratory personnel in Zimbabwe
title_full_unstemmed Task shifting for point-of-care early infant diagnosis: a comparison of the quality of testing between nurses and laboratory personnel in Zimbabwe
title_short Task shifting for point-of-care early infant diagnosis: a comparison of the quality of testing between nurses and laboratory personnel in Zimbabwe
title_sort task shifting for point-of-care early infant diagnosis: a comparison of the quality of testing between nurses and laboratory personnel in zimbabwe
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6986104/
https://www.ncbi.nlm.nih.gov/pubmed/31992332
http://dx.doi.org/10.1186/s12960-020-0449-2
work_keys_str_mv AT simmondsfrancism taskshiftingforpointofcareearlyinfantdiagnosisacomparisonofthequalityoftestingbetweennursesandlaboratorypersonnelinzimbabwe
AT cohnjennifere taskshiftingforpointofcareearlyinfantdiagnosisacomparisonofthequalityoftestingbetweennursesandlaboratorypersonnelinzimbabwe
AT mafaunehauroviw taskshiftingforpointofcareearlyinfantdiagnosisacomparisonofthequalityoftestingbetweennursesandlaboratorypersonnelinzimbabwe
AT nyamundayatichaonah taskshiftingforpointofcareearlyinfantdiagnosisacomparisonofthequalityoftestingbetweennursesandlaboratorypersonnelinzimbabwe
AT mahomvaagnes taskshiftingforpointofcareearlyinfantdiagnosisacomparisonofthequalityoftestingbetweennursesandlaboratorypersonnelinzimbabwe
AT chadambukaaddmore taskshiftingforpointofcareearlyinfantdiagnosisacomparisonofthequalityoftestingbetweennursesandlaboratorypersonnelinzimbabwe