Long-Term in vivo Release Profile of Dexamethasone-Loaded Silicone Rods Implanted Into the Cochlea of Guinea Pigs
Glucocorticoids are used intra-operatively in cochlear implant surgeries to reduce the inflammatory reaction caused by insertion trauma and the foreign body response against the electrode carrier after cochlear implantation. To prevent higher systemic concentrations of glucocorticoids that might cau...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6987378/ https://www.ncbi.nlm.nih.gov/pubmed/32038458 http://dx.doi.org/10.3389/fneur.2019.01377 |
_version_ | 1783492127023431680 |
---|---|
author | Liebau, Arne Schilp, Sören Mugridge, Kenneth Schön, Ilona Kather, Michel Kammerer, Bernd Tillein, Jochen Braun, Susanne Plontke, Stefan K. |
author_facet | Liebau, Arne Schilp, Sören Mugridge, Kenneth Schön, Ilona Kather, Michel Kammerer, Bernd Tillein, Jochen Braun, Susanne Plontke, Stefan K. |
author_sort | Liebau, Arne |
collection | PubMed |
description | Glucocorticoids are used intra-operatively in cochlear implant surgeries to reduce the inflammatory reaction caused by insertion trauma and the foreign body response against the electrode carrier after cochlear implantation. To prevent higher systemic concentrations of glucocorticoids that might cause undesirable systemic side effects, the drug should be applied locally. Since rapid clearance of glucocorticoids occurs in the inner ear fluid spaces, sustained application is supposedly more effective in suppressing foreign body and tissue reactions and in preserving neuronal structures. Embedding of the glucocorticoid dexamethasone into the cochlear implant electrode carrier and its continuous release may solve this problem. The aim of the present study was to examine how dexamethasone concentrations in the electrode carrier influence drug levels in the perilymph at different time points. Silicone rods were implanted through a cochleostomy into the basal turn of the scala tympani of guinea pigs. The silicone rods were loaded homogeneously with 0.1, 1, and 10% concentrations of dexamethasone. After implantation, dexamethasone concentrations in perilymph and cochlear tissue were measured at several time points over a period of up to 7 weeks. The kinetic was concentration-dependent and showed an initial burst release in the 10%- and the 1%-dexamethasone-loaded electrode carrier dummies. The 10%-loaded electrode carrier resulted in a more elevated and longer lasting burst release than the 1%-loaded carrier. Following this initial burst release phase, sustained dexamethasone levels of about 60 and 100 ng/ml were observed in the perilymph for the 1 and 10% loaded rods, respectively, during the remainder of the observation time. The 0.1% loaded carrier dummy achieved very low perilymph drug levels of about 0.5 ng/ml. The cochlear tissue drug concentration shows a similar dynamic to the perilymph drug concentration, but only reaches about 0.005–0.05% of the perilymph drug concentration. Dexamethasone can be released from silicone electrode carrier dummies in a controlled and sustained way over a period of several weeks, leading to constant drug concentrations in the scala tympani perilymph. No accumulation of dexamethasone was observed in the cochlear tissue. In consideration of experimental studies using similar drug depots and investigating physiological effects, an effective dose range between 50 and 100 ng/ml after burst release is suggested for the CI insertion trauma model. |
format | Online Article Text |
id | pubmed-6987378 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-69873782020-02-07 Long-Term in vivo Release Profile of Dexamethasone-Loaded Silicone Rods Implanted Into the Cochlea of Guinea Pigs Liebau, Arne Schilp, Sören Mugridge, Kenneth Schön, Ilona Kather, Michel Kammerer, Bernd Tillein, Jochen Braun, Susanne Plontke, Stefan K. Front Neurol Neurology Glucocorticoids are used intra-operatively in cochlear implant surgeries to reduce the inflammatory reaction caused by insertion trauma and the foreign body response against the electrode carrier after cochlear implantation. To prevent higher systemic concentrations of glucocorticoids that might cause undesirable systemic side effects, the drug should be applied locally. Since rapid clearance of glucocorticoids occurs in the inner ear fluid spaces, sustained application is supposedly more effective in suppressing foreign body and tissue reactions and in preserving neuronal structures. Embedding of the glucocorticoid dexamethasone into the cochlear implant electrode carrier and its continuous release may solve this problem. The aim of the present study was to examine how dexamethasone concentrations in the electrode carrier influence drug levels in the perilymph at different time points. Silicone rods were implanted through a cochleostomy into the basal turn of the scala tympani of guinea pigs. The silicone rods were loaded homogeneously with 0.1, 1, and 10% concentrations of dexamethasone. After implantation, dexamethasone concentrations in perilymph and cochlear tissue were measured at several time points over a period of up to 7 weeks. The kinetic was concentration-dependent and showed an initial burst release in the 10%- and the 1%-dexamethasone-loaded electrode carrier dummies. The 10%-loaded electrode carrier resulted in a more elevated and longer lasting burst release than the 1%-loaded carrier. Following this initial burst release phase, sustained dexamethasone levels of about 60 and 100 ng/ml were observed in the perilymph for the 1 and 10% loaded rods, respectively, during the remainder of the observation time. The 0.1% loaded carrier dummy achieved very low perilymph drug levels of about 0.5 ng/ml. The cochlear tissue drug concentration shows a similar dynamic to the perilymph drug concentration, but only reaches about 0.005–0.05% of the perilymph drug concentration. Dexamethasone can be released from silicone electrode carrier dummies in a controlled and sustained way over a period of several weeks, leading to constant drug concentrations in the scala tympani perilymph. No accumulation of dexamethasone was observed in the cochlear tissue. In consideration of experimental studies using similar drug depots and investigating physiological effects, an effective dose range between 50 and 100 ng/ml after burst release is suggested for the CI insertion trauma model. Frontiers Media S.A. 2020-01-22 /pmc/articles/PMC6987378/ /pubmed/32038458 http://dx.doi.org/10.3389/fneur.2019.01377 Text en Copyright © 2020 Liebau, Schilp, Mugridge, Schön, Kather, Kammerer, Tillein, Braun and Plontke. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Liebau, Arne Schilp, Sören Mugridge, Kenneth Schön, Ilona Kather, Michel Kammerer, Bernd Tillein, Jochen Braun, Susanne Plontke, Stefan K. Long-Term in vivo Release Profile of Dexamethasone-Loaded Silicone Rods Implanted Into the Cochlea of Guinea Pigs |
title | Long-Term in vivo Release Profile of Dexamethasone-Loaded Silicone Rods Implanted Into the Cochlea of Guinea Pigs |
title_full | Long-Term in vivo Release Profile of Dexamethasone-Loaded Silicone Rods Implanted Into the Cochlea of Guinea Pigs |
title_fullStr | Long-Term in vivo Release Profile of Dexamethasone-Loaded Silicone Rods Implanted Into the Cochlea of Guinea Pigs |
title_full_unstemmed | Long-Term in vivo Release Profile of Dexamethasone-Loaded Silicone Rods Implanted Into the Cochlea of Guinea Pigs |
title_short | Long-Term in vivo Release Profile of Dexamethasone-Loaded Silicone Rods Implanted Into the Cochlea of Guinea Pigs |
title_sort | long-term in vivo release profile of dexamethasone-loaded silicone rods implanted into the cochlea of guinea pigs |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6987378/ https://www.ncbi.nlm.nih.gov/pubmed/32038458 http://dx.doi.org/10.3389/fneur.2019.01377 |
work_keys_str_mv | AT liebauarne longterminvivoreleaseprofileofdexamethasoneloadedsiliconerodsimplantedintothecochleaofguineapigs AT schilpsoren longterminvivoreleaseprofileofdexamethasoneloadedsiliconerodsimplantedintothecochleaofguineapigs AT mugridgekenneth longterminvivoreleaseprofileofdexamethasoneloadedsiliconerodsimplantedintothecochleaofguineapigs AT schonilona longterminvivoreleaseprofileofdexamethasoneloadedsiliconerodsimplantedintothecochleaofguineapigs AT kathermichel longterminvivoreleaseprofileofdexamethasoneloadedsiliconerodsimplantedintothecochleaofguineapigs AT kammererbernd longterminvivoreleaseprofileofdexamethasoneloadedsiliconerodsimplantedintothecochleaofguineapigs AT tilleinjochen longterminvivoreleaseprofileofdexamethasoneloadedsiliconerodsimplantedintothecochleaofguineapigs AT braunsusanne longterminvivoreleaseprofileofdexamethasoneloadedsiliconerodsimplantedintothecochleaofguineapigs AT plontkestefank longterminvivoreleaseprofileofdexamethasoneloadedsiliconerodsimplantedintothecochleaofguineapigs |