Cargando…

Neuropathy Caused by Metal Hypersensitivity after Placement of Stainless Steel Plate

Metal hypersensitivity is a rare complication for implants especially with neuropathy involvement. There was not any previous report suggesting metal hypersensitivity manifested in the form of neuropathy or tendinopathy from metal plate implantation. Here, we present a case of a 42-year-old female w...

Descripción completa

Detalles Bibliográficos
Autores principales: Niempoog, Sunyarn, Kukreja, Seksan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6988665/
https://www.ncbi.nlm.nih.gov/pubmed/32015923
http://dx.doi.org/10.1155/2020/9789021
_version_ 1783492297258696704
author Niempoog, Sunyarn
Kukreja, Seksan
author_facet Niempoog, Sunyarn
Kukreja, Seksan
author_sort Niempoog, Sunyarn
collection PubMed
description Metal hypersensitivity is a rare complication for implants especially with neuropathy involvement. There was not any previous report suggesting metal hypersensitivity manifested in the form of neuropathy or tendinopathy from metal plate implantation. Here, we present a case of a 42-year-old female with chronic ulnar wrist pain and unremarkable physical and radiological findings. Ulna shortening osteotomy with small stainless steel-made DCP and screw fixation was done. On the third day postoperative, the patient developed pain, swelling, ulnar neuropathy, and flexor tendon contracture. Severe adhesion was found around the implant and the ulnar nerve. Minimal skin patch testing reaction and pathological study suggest a cell-mediated delayed type IV hypersensitivity reaction. A titanium-made LCP was later implanted in place of the stainless steel-made DCP. The patient's clinical status significantly improved after the operation. Metal hypersensitivity in this patient was unprecedented and unique. The severity of the reaction and its location close to the ulnar nerve may predispose to the intensity of the reaction.
format Online
Article
Text
id pubmed-6988665
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-69886652020-02-03 Neuropathy Caused by Metal Hypersensitivity after Placement of Stainless Steel Plate Niempoog, Sunyarn Kukreja, Seksan Case Rep Orthop Case Report Metal hypersensitivity is a rare complication for implants especially with neuropathy involvement. There was not any previous report suggesting metal hypersensitivity manifested in the form of neuropathy or tendinopathy from metal plate implantation. Here, we present a case of a 42-year-old female with chronic ulnar wrist pain and unremarkable physical and radiological findings. Ulna shortening osteotomy with small stainless steel-made DCP and screw fixation was done. On the third day postoperative, the patient developed pain, swelling, ulnar neuropathy, and flexor tendon contracture. Severe adhesion was found around the implant and the ulnar nerve. Minimal skin patch testing reaction and pathological study suggest a cell-mediated delayed type IV hypersensitivity reaction. A titanium-made LCP was later implanted in place of the stainless steel-made DCP. The patient's clinical status significantly improved after the operation. Metal hypersensitivity in this patient was unprecedented and unique. The severity of the reaction and its location close to the ulnar nerve may predispose to the intensity of the reaction. Hindawi 2020-01-14 /pmc/articles/PMC6988665/ /pubmed/32015923 http://dx.doi.org/10.1155/2020/9789021 Text en Copyright © 2020 Sunyarn Niempoog and Seksan Kukreja. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Niempoog, Sunyarn
Kukreja, Seksan
Neuropathy Caused by Metal Hypersensitivity after Placement of Stainless Steel Plate
title Neuropathy Caused by Metal Hypersensitivity after Placement of Stainless Steel Plate
title_full Neuropathy Caused by Metal Hypersensitivity after Placement of Stainless Steel Plate
title_fullStr Neuropathy Caused by Metal Hypersensitivity after Placement of Stainless Steel Plate
title_full_unstemmed Neuropathy Caused by Metal Hypersensitivity after Placement of Stainless Steel Plate
title_short Neuropathy Caused by Metal Hypersensitivity after Placement of Stainless Steel Plate
title_sort neuropathy caused by metal hypersensitivity after placement of stainless steel plate
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6988665/
https://www.ncbi.nlm.nih.gov/pubmed/32015923
http://dx.doi.org/10.1155/2020/9789021
work_keys_str_mv AT niempoogsunyarn neuropathycausedbymetalhypersensitivityafterplacementofstainlesssteelplate
AT kukrejaseksan neuropathycausedbymetalhypersensitivityafterplacementofstainlesssteelplate