Cargando…
Determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry
An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantification of donepezil in human plasma. Donepezil and donepezil-D4 were extracted from human plasma by liquid-liquid extraction using a mixture of hexane and ethyl acetate...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society for Clinical Pharmacology and Therapeutics
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6989263/ https://www.ncbi.nlm.nih.gov/pubmed/32055551 http://dx.doi.org/10.12793/tcp.2018.26.2.64 |
_version_ | 1783492370911723520 |
---|---|
author | Jeong, Hyeon-Cheol Park, Jeong-Eun Hyun, Ji-Yeon Park, Min-Kyu Shin, Dong-Seong Shin, Kwang-Hee |
author_facet | Jeong, Hyeon-Cheol Park, Jeong-Eun Hyun, Ji-Yeon Park, Min-Kyu Shin, Dong-Seong Shin, Kwang-Hee |
author_sort | Jeong, Hyeon-Cheol |
collection | PubMed |
description | An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantification of donepezil in human plasma. Donepezil and donepezil-D4 were extracted from human plasma by liquid-liquid extraction using a mixture of hexane and ethyl acetate (70:30 v/v). The extracted samples were analyzed using a Thermo Hypersil Gold C18 column with 5% acetic acid in 20 mM ammonium acetate buffer (pH 3.3) and 100% acetonitrile as a mobile phase with the 60:40 (v:v) isocratic method, at a flow rate of 0.3 mL/min. The injection volume was 3 µL, and the total run time was 3 min. Inter- and intra-batch accuracies ranged from 98.0% to 110.0%, and the precision was below 8%. The developed method was successfully applied to the quantification of donepezil in human plasma. The mean (standard deviation) maximum concentration and the median (range) time to maximum concentration were 8.6 (2.0) ng/mL and 2.0 h (1.0~5.0 h), respectively, in healthy Koreans after oral administration of 5 mg donepezil. |
format | Online Article Text |
id | pubmed-6989263 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Korean Society for Clinical Pharmacology and Therapeutics |
record_format | MEDLINE/PubMed |
spelling | pubmed-69892632020-02-13 Determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry Jeong, Hyeon-Cheol Park, Jeong-Eun Hyun, Ji-Yeon Park, Min-Kyu Shin, Dong-Seong Shin, Kwang-Hee Transl Clin Pharmacol Original Article An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantification of donepezil in human plasma. Donepezil and donepezil-D4 were extracted from human plasma by liquid-liquid extraction using a mixture of hexane and ethyl acetate (70:30 v/v). The extracted samples were analyzed using a Thermo Hypersil Gold C18 column with 5% acetic acid in 20 mM ammonium acetate buffer (pH 3.3) and 100% acetonitrile as a mobile phase with the 60:40 (v:v) isocratic method, at a flow rate of 0.3 mL/min. The injection volume was 3 µL, and the total run time was 3 min. Inter- and intra-batch accuracies ranged from 98.0% to 110.0%, and the precision was below 8%. The developed method was successfully applied to the quantification of donepezil in human plasma. The mean (standard deviation) maximum concentration and the median (range) time to maximum concentration were 8.6 (2.0) ng/mL and 2.0 h (1.0~5.0 h), respectively, in healthy Koreans after oral administration of 5 mg donepezil. Korean Society for Clinical Pharmacology and Therapeutics 2018-06 2018-06-18 /pmc/articles/PMC6989263/ /pubmed/32055551 http://dx.doi.org/10.12793/tcp.2018.26.2.64 Text en Copyright © 2018 Translational and Clinical Pharmacology http://creativecommons.org/licenses/by-nc/3.0/ It is identical to the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/). |
spellingShingle | Original Article Jeong, Hyeon-Cheol Park, Jeong-Eun Hyun, Ji-Yeon Park, Min-Kyu Shin, Dong-Seong Shin, Kwang-Hee Determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry |
title | Determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry |
title_full | Determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry |
title_fullStr | Determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry |
title_full_unstemmed | Determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry |
title_short | Determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry |
title_sort | determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6989263/ https://www.ncbi.nlm.nih.gov/pubmed/32055551 http://dx.doi.org/10.12793/tcp.2018.26.2.64 |
work_keys_str_mv | AT jeonghyeoncheol determinationofdonepezilinhumanplasmausingultraperformanceliquidchromatographytandemmassspectrometry AT parkjeongeun determinationofdonepezilinhumanplasmausingultraperformanceliquidchromatographytandemmassspectrometry AT hyunjiyeon determinationofdonepezilinhumanplasmausingultraperformanceliquidchromatographytandemmassspectrometry AT parkminkyu determinationofdonepezilinhumanplasmausingultraperformanceliquidchromatographytandemmassspectrometry AT shindongseong determinationofdonepezilinhumanplasmausingultraperformanceliquidchromatographytandemmassspectrometry AT shinkwanghee determinationofdonepezilinhumanplasmausingultraperformanceliquidchromatographytandemmassspectrometry |