Cargando…

A compression transmission device for the evaluation of bonding strength of biocompatible microfluidic and biochip materials and systems

Bonding of a variety of inorganic and organic polymers as multi-layered structures is one of the main challenges for biochip production even to date, since the chemical nature of these materials often does not allow easy and straight forward bonding and proper sealing. After selection of an appropri...

Descripción completa

Detalles Bibliográficos
Autores principales: Kratz, S. R. A., Bachmann, B., Spitz, S., Höll, G., Eilenberger, C., Goeritz, H., Ertl, P., Rothbauer, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6989640/
https://www.ncbi.nlm.nih.gov/pubmed/31996733
http://dx.doi.org/10.1038/s41598-020-58373-0
_version_ 1783492444768174080
author Kratz, S. R. A.
Bachmann, B.
Spitz, S.
Höll, G.
Eilenberger, C.
Goeritz, H.
Ertl, P.
Rothbauer, M.
author_facet Kratz, S. R. A.
Bachmann, B.
Spitz, S.
Höll, G.
Eilenberger, C.
Goeritz, H.
Ertl, P.
Rothbauer, M.
author_sort Kratz, S. R. A.
collection PubMed
description Bonding of a variety of inorganic and organic polymers as multi-layered structures is one of the main challenges for biochip production even to date, since the chemical nature of these materials often does not allow easy and straight forward bonding and proper sealing. After selection of an appropriate method to bond the chosen materials to form a complex biochip, function and stability of bonding either requires qualitative burst tests or expensive mechanical multi-test stations, that often do not have the right adaptors to clamp biochip slides without destruction. Therefore, we have developed a simple and inexpensive bonding test based on 3D printed transmission elements that translate compressive forces via manual compression, hand press or hydraulic press compression into shear and tensile force. Mechanical stress simulations showed that design of the bonding geometry and size must be considered for bonding tests since the stress distribution thus bonding strength heavily varies with size but also with geometry. We demonstrate the broad applicability of our 3D printed bonding test system by testing the most frequent bonding strategies in combination with the respective most frequently used biochip material in a force-to-failure study. All evaluated materials are biocompatible and used in cell-based biochip devices. This study is evaluating state-of-the-art bonding approaches used for sealing of microfluidic biochips including adhesive bonding, plasma bonding, solvent bonding as well as bonding mediated by amino-silane monolayers or even functional thiol-ene epoxy biochip materials that obviate intermediate adhesive layers.
format Online
Article
Text
id pubmed-6989640
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-69896402020-02-05 A compression transmission device for the evaluation of bonding strength of biocompatible microfluidic and biochip materials and systems Kratz, S. R. A. Bachmann, B. Spitz, S. Höll, G. Eilenberger, C. Goeritz, H. Ertl, P. Rothbauer, M. Sci Rep Article Bonding of a variety of inorganic and organic polymers as multi-layered structures is one of the main challenges for biochip production even to date, since the chemical nature of these materials often does not allow easy and straight forward bonding and proper sealing. After selection of an appropriate method to bond the chosen materials to form a complex biochip, function and stability of bonding either requires qualitative burst tests or expensive mechanical multi-test stations, that often do not have the right adaptors to clamp biochip slides without destruction. Therefore, we have developed a simple and inexpensive bonding test based on 3D printed transmission elements that translate compressive forces via manual compression, hand press or hydraulic press compression into shear and tensile force. Mechanical stress simulations showed that design of the bonding geometry and size must be considered for bonding tests since the stress distribution thus bonding strength heavily varies with size but also with geometry. We demonstrate the broad applicability of our 3D printed bonding test system by testing the most frequent bonding strategies in combination with the respective most frequently used biochip material in a force-to-failure study. All evaluated materials are biocompatible and used in cell-based biochip devices. This study is evaluating state-of-the-art bonding approaches used for sealing of microfluidic biochips including adhesive bonding, plasma bonding, solvent bonding as well as bonding mediated by amino-silane monolayers or even functional thiol-ene epoxy biochip materials that obviate intermediate adhesive layers. Nature Publishing Group UK 2020-01-29 /pmc/articles/PMC6989640/ /pubmed/31996733 http://dx.doi.org/10.1038/s41598-020-58373-0 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Kratz, S. R. A.
Bachmann, B.
Spitz, S.
Höll, G.
Eilenberger, C.
Goeritz, H.
Ertl, P.
Rothbauer, M.
A compression transmission device for the evaluation of bonding strength of biocompatible microfluidic and biochip materials and systems
title A compression transmission device for the evaluation of bonding strength of biocompatible microfluidic and biochip materials and systems
title_full A compression transmission device for the evaluation of bonding strength of biocompatible microfluidic and biochip materials and systems
title_fullStr A compression transmission device for the evaluation of bonding strength of biocompatible microfluidic and biochip materials and systems
title_full_unstemmed A compression transmission device for the evaluation of bonding strength of biocompatible microfluidic and biochip materials and systems
title_short A compression transmission device for the evaluation of bonding strength of biocompatible microfluidic and biochip materials and systems
title_sort compression transmission device for the evaluation of bonding strength of biocompatible microfluidic and biochip materials and systems
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6989640/
https://www.ncbi.nlm.nih.gov/pubmed/31996733
http://dx.doi.org/10.1038/s41598-020-58373-0
work_keys_str_mv AT kratzsra acompressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT bachmannb acompressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT spitzs acompressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT hollg acompressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT eilenbergerc acompressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT goeritzh acompressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT ertlp acompressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT rothbauerm acompressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT kratzsra compressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT bachmannb compressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT spitzs compressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT hollg compressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT eilenbergerc compressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT goeritzh compressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT ertlp compressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems
AT rothbauerm compressiontransmissiondevicefortheevaluationofbondingstrengthofbiocompatiblemicrofluidicandbiochipmaterialsandsystems