Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose
BACKGROUND: To assess left ventricular function and coronary artery simultaneously by third-generation dual-source computed tomography (CT) using a low radiation dose. METHODS: A total of 48 patients (36 men, 12 women; mean age 57.0 ± 9.5 years) who underwent both electrocardiography-gated cardiac C...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Echocardiography
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6992922/ https://www.ncbi.nlm.nih.gov/pubmed/31805621 http://dx.doi.org/10.4250/jcvi.2019.0066 |
_version_ | 1783492930765324288 |
---|---|
author | Lee, Ji Won Nam, Kyung Jin Kim, Jin You Jeong, Yeon Joo Lee, Geewon Park, So Min Lim, Soo Jin Choo, Ki Seok |
author_facet | Lee, Ji Won Nam, Kyung Jin Kim, Jin You Jeong, Yeon Joo Lee, Geewon Park, So Min Lim, Soo Jin Choo, Ki Seok |
author_sort | Lee, Ji Won |
collection | PubMed |
description | BACKGROUND: To assess left ventricular function and coronary artery simultaneously by third-generation dual-source computed tomography (CT) using a low radiation dose. METHODS: A total of 48 patients (36 men, 12 women; mean age 57.0 ± 9.5 years) who underwent both electrocardiography-gated cardiac CT angiography (CCTA) using 70–90 kVp and echocardiography were included in this retrospective study. The correlation between left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and left ventricular ejection fraction (LVEF) measured using CCTA and echocardiography was determined. The quality of coronary artery images was analyzed using a 4-point scale (1, excellent; 4, poor). The effective radiation dose of CCTA was calculated. RESULTS: Mean heart rate during the CT examination was 59.9 ± 9.9 bpm (range 38–79) and the body mass index of 48 patients was 24.5 ± 2.6 kg/m(2) (range 17.0–29.4). LVEDV, LVESV, and LVEF measured using CCTA and echocardiography demonstrated a fair to moderate correlation (Pearson correlation coefficient: r = 0.395, p = 0.005 for LVEDV; r = 0.509. p < 0.001 for LVESV; r = 0.551, p < 0.001 for LVEF). Average image quality score of coronary arteries was 1.0 ± 0.1 (range 1–2). A total of 99.0% (783 of 791) of segments had an excellent image quality score, and 1.0% (8 of 791) of segments had a good score. Mean effective radiation dose was 2.2 ± 0.7 mSv. CONCLUSIONS: Third-generation dual-source CT using a low tube voltage simultaneously provides information regarding LV function and coronary artery disease at a low radiation dose. It can serve as an alternative option for functional assessment, particularly when other imaging modalities are inadequate. |
format | Online Article Text |
id | pubmed-6992922 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Korean Society of Echocardiography |
record_format | MEDLINE/PubMed |
spelling | pubmed-69929222020-02-10 Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose Lee, Ji Won Nam, Kyung Jin Kim, Jin You Jeong, Yeon Joo Lee, Geewon Park, So Min Lim, Soo Jin Choo, Ki Seok J Cardiovasc Imaging Original Article BACKGROUND: To assess left ventricular function and coronary artery simultaneously by third-generation dual-source computed tomography (CT) using a low radiation dose. METHODS: A total of 48 patients (36 men, 12 women; mean age 57.0 ± 9.5 years) who underwent both electrocardiography-gated cardiac CT angiography (CCTA) using 70–90 kVp and echocardiography were included in this retrospective study. The correlation between left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and left ventricular ejection fraction (LVEF) measured using CCTA and echocardiography was determined. The quality of coronary artery images was analyzed using a 4-point scale (1, excellent; 4, poor). The effective radiation dose of CCTA was calculated. RESULTS: Mean heart rate during the CT examination was 59.9 ± 9.9 bpm (range 38–79) and the body mass index of 48 patients was 24.5 ± 2.6 kg/m(2) (range 17.0–29.4). LVEDV, LVESV, and LVEF measured using CCTA and echocardiography demonstrated a fair to moderate correlation (Pearson correlation coefficient: r = 0.395, p = 0.005 for LVEDV; r = 0.509. p < 0.001 for LVESV; r = 0.551, p < 0.001 for LVEF). Average image quality score of coronary arteries was 1.0 ± 0.1 (range 1–2). A total of 99.0% (783 of 791) of segments had an excellent image quality score, and 1.0% (8 of 791) of segments had a good score. Mean effective radiation dose was 2.2 ± 0.7 mSv. CONCLUSIONS: Third-generation dual-source CT using a low tube voltage simultaneously provides information regarding LV function and coronary artery disease at a low radiation dose. It can serve as an alternative option for functional assessment, particularly when other imaging modalities are inadequate. Korean Society of Echocardiography 2020-01 2019-11-20 /pmc/articles/PMC6992922/ /pubmed/31805621 http://dx.doi.org/10.4250/jcvi.2019.0066 Text en Copyright © 2020 Korean Society of Echocardiography https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Ji Won Nam, Kyung Jin Kim, Jin You Jeong, Yeon Joo Lee, Geewon Park, So Min Lim, Soo Jin Choo, Ki Seok Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose |
title | Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose |
title_full | Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose |
title_fullStr | Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose |
title_full_unstemmed | Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose |
title_short | Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose |
title_sort | simultaneous assessment of left ventricular function and coronary artery anatomy by third-generation dual-source computed tomography using a low radiation dose |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6992922/ https://www.ncbi.nlm.nih.gov/pubmed/31805621 http://dx.doi.org/10.4250/jcvi.2019.0066 |
work_keys_str_mv | AT leejiwon simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose AT namkyungjin simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose AT kimjinyou simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose AT jeongyeonjoo simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose AT leegeewon simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose AT parksomin simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose AT limsoojin simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose AT chookiseok simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose |