Cargando…

Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose

BACKGROUND: To assess left ventricular function and coronary artery simultaneously by third-generation dual-source computed tomography (CT) using a low radiation dose. METHODS: A total of 48 patients (36 men, 12 women; mean age 57.0 ± 9.5 years) who underwent both electrocardiography-gated cardiac C...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Ji Won, Nam, Kyung Jin, Kim, Jin You, Jeong, Yeon Joo, Lee, Geewon, Park, So Min, Lim, Soo Jin, Choo, Ki Seok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Echocardiography 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6992922/
https://www.ncbi.nlm.nih.gov/pubmed/31805621
http://dx.doi.org/10.4250/jcvi.2019.0066
_version_ 1783492930765324288
author Lee, Ji Won
Nam, Kyung Jin
Kim, Jin You
Jeong, Yeon Joo
Lee, Geewon
Park, So Min
Lim, Soo Jin
Choo, Ki Seok
author_facet Lee, Ji Won
Nam, Kyung Jin
Kim, Jin You
Jeong, Yeon Joo
Lee, Geewon
Park, So Min
Lim, Soo Jin
Choo, Ki Seok
author_sort Lee, Ji Won
collection PubMed
description BACKGROUND: To assess left ventricular function and coronary artery simultaneously by third-generation dual-source computed tomography (CT) using a low radiation dose. METHODS: A total of 48 patients (36 men, 12 women; mean age 57.0 ± 9.5 years) who underwent both electrocardiography-gated cardiac CT angiography (CCTA) using 70–90 kVp and echocardiography were included in this retrospective study. The correlation between left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and left ventricular ejection fraction (LVEF) measured using CCTA and echocardiography was determined. The quality of coronary artery images was analyzed using a 4-point scale (1, excellent; 4, poor). The effective radiation dose of CCTA was calculated. RESULTS: Mean heart rate during the CT examination was 59.9 ± 9.9 bpm (range 38–79) and the body mass index of 48 patients was 24.5 ± 2.6 kg/m(2) (range 17.0–29.4). LVEDV, LVESV, and LVEF measured using CCTA and echocardiography demonstrated a fair to moderate correlation (Pearson correlation coefficient: r = 0.395, p = 0.005 for LVEDV; r = 0.509. p < 0.001 for LVESV; r = 0.551, p < 0.001 for LVEF). Average image quality score of coronary arteries was 1.0 ± 0.1 (range 1–2). A total of 99.0% (783 of 791) of segments had an excellent image quality score, and 1.0% (8 of 791) of segments had a good score. Mean effective radiation dose was 2.2 ± 0.7 mSv. CONCLUSIONS: Third-generation dual-source CT using a low tube voltage simultaneously provides information regarding LV function and coronary artery disease at a low radiation dose. It can serve as an alternative option for functional assessment, particularly when other imaging modalities are inadequate.
format Online
Article
Text
id pubmed-6992922
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Society of Echocardiography
record_format MEDLINE/PubMed
spelling pubmed-69929222020-02-10 Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose Lee, Ji Won Nam, Kyung Jin Kim, Jin You Jeong, Yeon Joo Lee, Geewon Park, So Min Lim, Soo Jin Choo, Ki Seok J Cardiovasc Imaging Original Article BACKGROUND: To assess left ventricular function and coronary artery simultaneously by third-generation dual-source computed tomography (CT) using a low radiation dose. METHODS: A total of 48 patients (36 men, 12 women; mean age 57.0 ± 9.5 years) who underwent both electrocardiography-gated cardiac CT angiography (CCTA) using 70–90 kVp and echocardiography were included in this retrospective study. The correlation between left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and left ventricular ejection fraction (LVEF) measured using CCTA and echocardiography was determined. The quality of coronary artery images was analyzed using a 4-point scale (1, excellent; 4, poor). The effective radiation dose of CCTA was calculated. RESULTS: Mean heart rate during the CT examination was 59.9 ± 9.9 bpm (range 38–79) and the body mass index of 48 patients was 24.5 ± 2.6 kg/m(2) (range 17.0–29.4). LVEDV, LVESV, and LVEF measured using CCTA and echocardiography demonstrated a fair to moderate correlation (Pearson correlation coefficient: r = 0.395, p = 0.005 for LVEDV; r = 0.509. p < 0.001 for LVESV; r = 0.551, p < 0.001 for LVEF). Average image quality score of coronary arteries was 1.0 ± 0.1 (range 1–2). A total of 99.0% (783 of 791) of segments had an excellent image quality score, and 1.0% (8 of 791) of segments had a good score. Mean effective radiation dose was 2.2 ± 0.7 mSv. CONCLUSIONS: Third-generation dual-source CT using a low tube voltage simultaneously provides information regarding LV function and coronary artery disease at a low radiation dose. It can serve as an alternative option for functional assessment, particularly when other imaging modalities are inadequate. Korean Society of Echocardiography 2020-01 2019-11-20 /pmc/articles/PMC6992922/ /pubmed/31805621 http://dx.doi.org/10.4250/jcvi.2019.0066 Text en Copyright © 2020 Korean Society of Echocardiography https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Ji Won
Nam, Kyung Jin
Kim, Jin You
Jeong, Yeon Joo
Lee, Geewon
Park, So Min
Lim, Soo Jin
Choo, Ki Seok
Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose
title Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose
title_full Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose
title_fullStr Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose
title_full_unstemmed Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose
title_short Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose
title_sort simultaneous assessment of left ventricular function and coronary artery anatomy by third-generation dual-source computed tomography using a low radiation dose
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6992922/
https://www.ncbi.nlm.nih.gov/pubmed/31805621
http://dx.doi.org/10.4250/jcvi.2019.0066
work_keys_str_mv AT leejiwon simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose
AT namkyungjin simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose
AT kimjinyou simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose
AT jeongyeonjoo simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose
AT leegeewon simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose
AT parksomin simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose
AT limsoojin simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose
AT chookiseok simultaneousassessmentofleftventricularfunctionandcoronaryarteryanatomybythirdgenerationdualsourcecomputedtomographyusingalowradiationdose