Cargando…

Automatic detection of retinal regions using fully convolutional networks for diagnosis of abnormal maculae in optical coherence tomography images

In conventional retinal region detection methods for optical coherence tomography (OCT) images, many parameters need to be set manually, which is often detrimental to their generalizability. We present a scheme to detect retinal regions based on fully convolutional networks (FCN) for automatic diagn...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Zhongyang, Sun, Yankui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6992962/
https://www.ncbi.nlm.nih.gov/pubmed/31111697
http://dx.doi.org/10.1117/1.JBO.24.5.056003
_version_ 1783492939902615552
author Sun, Zhongyang
Sun, Yankui
author_facet Sun, Zhongyang
Sun, Yankui
author_sort Sun, Zhongyang
collection PubMed
description In conventional retinal region detection methods for optical coherence tomography (OCT) images, many parameters need to be set manually, which is often detrimental to their generalizability. We present a scheme to detect retinal regions based on fully convolutional networks (FCN) for automatic diagnosis of abnormal maculae in OCT images. The FCN model is trained on 900 labeled age-related macular degeneration (AMD), diabetic macular edema (DME) and normal (NOR) OCT images. Its segmentation accuracy is validated and its effectiveness in recognizing abnormal maculae in OCT images is tested and compared with traditional methods, by using the spatial pyramid matching based on sparse coding (ScSPM) classifier and Inception V3 classifier on two datasets: Duke dataset and our clinic dataset. In our clinic dataset, we randomly selected half of the B-scans of each class (300 AMD, 300 DME, and 300 NOR) for training classifier and the rest (300 AMD, 300 DME, and 300 NOR) for testing with 10 repetitions. Average accuracy, sensitivity, and specificity of 98.69%, 98.03%, and 99.01% are obtained by using ScSPM classifier, and those of 99.69%, 99.53%, and 99.77% are obtained by using Inception V3 classifier. These two classification algorithms achieve 100% classification accuracy when directly applied to Duke dataset, where all the 45 OCT volumes are used as test set. Finally, FCN model with or without flattening and cropping and its influence on classification performance are discussed.
format Online
Article
Text
id pubmed-6992962
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-69929622020-02-10 Automatic detection of retinal regions using fully convolutional networks for diagnosis of abnormal maculae in optical coherence tomography images Sun, Zhongyang Sun, Yankui J Biomed Opt Imaging In conventional retinal region detection methods for optical coherence tomography (OCT) images, many parameters need to be set manually, which is often detrimental to their generalizability. We present a scheme to detect retinal regions based on fully convolutional networks (FCN) for automatic diagnosis of abnormal maculae in OCT images. The FCN model is trained on 900 labeled age-related macular degeneration (AMD), diabetic macular edema (DME) and normal (NOR) OCT images. Its segmentation accuracy is validated and its effectiveness in recognizing abnormal maculae in OCT images is tested and compared with traditional methods, by using the spatial pyramid matching based on sparse coding (ScSPM) classifier and Inception V3 classifier on two datasets: Duke dataset and our clinic dataset. In our clinic dataset, we randomly selected half of the B-scans of each class (300 AMD, 300 DME, and 300 NOR) for training classifier and the rest (300 AMD, 300 DME, and 300 NOR) for testing with 10 repetitions. Average accuracy, sensitivity, and specificity of 98.69%, 98.03%, and 99.01% are obtained by using ScSPM classifier, and those of 99.69%, 99.53%, and 99.77% are obtained by using Inception V3 classifier. These two classification algorithms achieve 100% classification accuracy when directly applied to Duke dataset, where all the 45 OCT volumes are used as test set. Finally, FCN model with or without flattening and cropping and its influence on classification performance are discussed. Society of Photo-Optical Instrumentation Engineers 2019-05-20 2019-05 /pmc/articles/PMC6992962/ /pubmed/31111697 http://dx.doi.org/10.1117/1.JBO.24.5.056003 Text en © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Imaging
Sun, Zhongyang
Sun, Yankui
Automatic detection of retinal regions using fully convolutional networks for diagnosis of abnormal maculae in optical coherence tomography images
title Automatic detection of retinal regions using fully convolutional networks for diagnosis of abnormal maculae in optical coherence tomography images
title_full Automatic detection of retinal regions using fully convolutional networks for diagnosis of abnormal maculae in optical coherence tomography images
title_fullStr Automatic detection of retinal regions using fully convolutional networks for diagnosis of abnormal maculae in optical coherence tomography images
title_full_unstemmed Automatic detection of retinal regions using fully convolutional networks for diagnosis of abnormal maculae in optical coherence tomography images
title_short Automatic detection of retinal regions using fully convolutional networks for diagnosis of abnormal maculae in optical coherence tomography images
title_sort automatic detection of retinal regions using fully convolutional networks for diagnosis of abnormal maculae in optical coherence tomography images
topic Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6992962/
https://www.ncbi.nlm.nih.gov/pubmed/31111697
http://dx.doi.org/10.1117/1.JBO.24.5.056003
work_keys_str_mv AT sunzhongyang automaticdetectionofretinalregionsusingfullyconvolutionalnetworksfordiagnosisofabnormalmaculaeinopticalcoherencetomographyimages
AT sunyankui automaticdetectionofretinalregionsusingfullyconvolutionalnetworksfordiagnosisofabnormalmaculaeinopticalcoherencetomographyimages