Cargando…

Effects of steroidal implants on feedlot performance, carcass characteristics, and serum and meat estradiol-17β concentrations of Holstein steers

The objectives of the study were to determine the effect of steroidal implants on growth performance, carcass characteristics, and estradiol-17β (E(2)) concentrations in the blood and longissimus muscle of Holstein steers fed a grain-based diet. Seventy Holstein steers (average initial BW = 275 ± 6....

Descripción completa

Detalles Bibliográficos
Autores principales: Carvalho, Pedro Henrique Vilela, Perry, George A, Felix, Tara L
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6994095/
https://www.ncbi.nlm.nih.gov/pubmed/32704980
http://dx.doi.org/10.1093/tas/txz186
_version_ 1783493153360183296
author Carvalho, Pedro Henrique Vilela
Perry, George A
Felix, Tara L
author_facet Carvalho, Pedro Henrique Vilela
Perry, George A
Felix, Tara L
author_sort Carvalho, Pedro Henrique Vilela
collection PubMed
description The objectives of the study were to determine the effect of steroidal implants on growth performance, carcass characteristics, and estradiol-17β (E(2)) concentrations in the blood and longissimus muscle of Holstein steers fed a grain-based diet. Seventy Holstein steers (average initial BW = 275 ± 6.4 kg, 10 to 12 mo of age) were assigned to treatments: (i) implanted with 80 mg of trenbolone acetate (TBA) and 16 mg of E(2) (Component TE-IS with Tylan; Elanco Animal Health, Greenfield, IN) at the start of the trial (day 0), and reimplanted with 120 mg of TBA and 24 mg of E(2) (Component TE-S with Tylan; Elanco Animal Health) on day 84 of the experiment; or (ii) no implant. Implanted Holstein steers were heavier (P ≤ 0.01) than nonimplanted Holstein steers in the middle (day 84) and at the end of the experiment (day 186). Implanting Holstein steers increased (P < 0.01) average daily gain (ADG) and dry matter intake (DMI) without affecting gain-to-feed ratio compared with nonimplanted animals. Carcasses from implanted Holstein steers had greater (P < 0.01) hot carcass weight (HCW) and longissimus muscle (LM) area than carcasses from nonimplanted steers. Implanting did not affect (P ≥ 0.21) other carcass characteristics. There was an increase (P = 0.03) of 1.3 pg of E(2)/g of muscle in implanted Holstein steers compared with that from nonimplanted Holstein steers. There was an implant × day interaction (P < 0.01) in serum E(2) concentrations. Serum E(2) concentrations were not altered in nonimplanted Holstein steers, whereas E(2) concentration increased (P < 0.01) after steers were implanted, regardless of implant characteristics. Serum E(2) peaked at 28 days after the first implant and then rapidly declined after day 56. In summary, steroidal implants administered on days 0 and 84 increased DMI, ADG, HCW, and LM area in Holstein steers compared with nonimplanted steers due to increased serum E(2) concentrations. However, these changes did not improve feed efficiency or other carcass characteristics.
format Online
Article
Text
id pubmed-6994095
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-69940952020-07-22 Effects of steroidal implants on feedlot performance, carcass characteristics, and serum and meat estradiol-17β concentrations of Holstein steers Carvalho, Pedro Henrique Vilela Perry, George A Felix, Tara L Transl Anim Sci Ruminant Nutrition The objectives of the study were to determine the effect of steroidal implants on growth performance, carcass characteristics, and estradiol-17β (E(2)) concentrations in the blood and longissimus muscle of Holstein steers fed a grain-based diet. Seventy Holstein steers (average initial BW = 275 ± 6.4 kg, 10 to 12 mo of age) were assigned to treatments: (i) implanted with 80 mg of trenbolone acetate (TBA) and 16 mg of E(2) (Component TE-IS with Tylan; Elanco Animal Health, Greenfield, IN) at the start of the trial (day 0), and reimplanted with 120 mg of TBA and 24 mg of E(2) (Component TE-S with Tylan; Elanco Animal Health) on day 84 of the experiment; or (ii) no implant. Implanted Holstein steers were heavier (P ≤ 0.01) than nonimplanted Holstein steers in the middle (day 84) and at the end of the experiment (day 186). Implanting Holstein steers increased (P < 0.01) average daily gain (ADG) and dry matter intake (DMI) without affecting gain-to-feed ratio compared with nonimplanted animals. Carcasses from implanted Holstein steers had greater (P < 0.01) hot carcass weight (HCW) and longissimus muscle (LM) area than carcasses from nonimplanted steers. Implanting did not affect (P ≥ 0.21) other carcass characteristics. There was an increase (P = 0.03) of 1.3 pg of E(2)/g of muscle in implanted Holstein steers compared with that from nonimplanted Holstein steers. There was an implant × day interaction (P < 0.01) in serum E(2) concentrations. Serum E(2) concentrations were not altered in nonimplanted Holstein steers, whereas E(2) concentration increased (P < 0.01) after steers were implanted, regardless of implant characteristics. Serum E(2) peaked at 28 days after the first implant and then rapidly declined after day 56. In summary, steroidal implants administered on days 0 and 84 increased DMI, ADG, HCW, and LM area in Holstein steers compared with nonimplanted steers due to increased serum E(2) concentrations. However, these changes did not improve feed efficiency or other carcass characteristics. Oxford University Press 2019-12-10 /pmc/articles/PMC6994095/ /pubmed/32704980 http://dx.doi.org/10.1093/tas/txz186 Text en © The Author(s) 2019. Published by Oxford University Press on behalf of the American Society of Animal Science. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Ruminant Nutrition
Carvalho, Pedro Henrique Vilela
Perry, George A
Felix, Tara L
Effects of steroidal implants on feedlot performance, carcass characteristics, and serum and meat estradiol-17β concentrations of Holstein steers
title Effects of steroidal implants on feedlot performance, carcass characteristics, and serum and meat estradiol-17β concentrations of Holstein steers
title_full Effects of steroidal implants on feedlot performance, carcass characteristics, and serum and meat estradiol-17β concentrations of Holstein steers
title_fullStr Effects of steroidal implants on feedlot performance, carcass characteristics, and serum and meat estradiol-17β concentrations of Holstein steers
title_full_unstemmed Effects of steroidal implants on feedlot performance, carcass characteristics, and serum and meat estradiol-17β concentrations of Holstein steers
title_short Effects of steroidal implants on feedlot performance, carcass characteristics, and serum and meat estradiol-17β concentrations of Holstein steers
title_sort effects of steroidal implants on feedlot performance, carcass characteristics, and serum and meat estradiol-17β concentrations of holstein steers
topic Ruminant Nutrition
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6994095/
https://www.ncbi.nlm.nih.gov/pubmed/32704980
http://dx.doi.org/10.1093/tas/txz186
work_keys_str_mv AT carvalhopedrohenriquevilela effectsofsteroidalimplantsonfeedlotperformancecarcasscharacteristicsandserumandmeatestradiol17bconcentrationsofholsteinsteers
AT perrygeorgea effectsofsteroidalimplantsonfeedlotperformancecarcasscharacteristicsandserumandmeatestradiol17bconcentrationsofholsteinsteers
AT felixtaral effectsofsteroidalimplantsonfeedlotperformancecarcasscharacteristicsandserumandmeatestradiol17bconcentrationsofholsteinsteers