Cargando…

Comparison of the SuperARMS and ARMS for detecting EGFR mutations in liquid-based cytology specimens from NSCLC patients

BACKGROUND: Non-surgical cytological specimens are adequate not only for accurate histological subtyping but also for molecular profiling. A modified amplification refractory mutation system polymerase chain reaction (ARMS PCR), known as SuperARMS PCR, was improved by optimizing the primers designat...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Wei, Cao, Ziyang, Zhang, Wei, Zhang, Liping, Hou, Likun, Wu, Chunyan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6995041/
https://www.ncbi.nlm.nih.gov/pubmed/32005253
http://dx.doi.org/10.1186/s13000-019-0910-5
_version_ 1783493302079717376
author Wu, Wei
Cao, Ziyang
Zhang, Wei
Zhang, Liping
Hou, Likun
Wu, Chunyan
author_facet Wu, Wei
Cao, Ziyang
Zhang, Wei
Zhang, Liping
Hou, Likun
Wu, Chunyan
author_sort Wu, Wei
collection PubMed
description BACKGROUND: Non-surgical cytological specimens are adequate not only for accurate histological subtyping but also for molecular profiling. A modified amplification refractory mutation system polymerase chain reaction (ARMS PCR), known as SuperARMS PCR, was improved by optimizing the primers designation, which provides a higher sensitivity and specificity approach for free plasma DNA detection. It is unclear whether SuperARMS PCR detects epidermal growth factor receptor (EGFR) mutations in cytology samples. The aim of this study was to compare the EGFR mutations detected by ARMS PCR and SuperARMS PCR in cytology samples derived from advanced non-small cell lung cancer (NSCLC) patients. METHODS: From March 2016 to March 2018, a total of 234 cytological samples were obtained from primary or metastatic lesions of NSCLC, including 144 fine-needle aspirations (FNAs), 36 endobroncheal ultrasonography (EBUS) FNAs, 36 transbronchial needle aspirations (TBNAs) and 18 pleural effusion (PLEs). EGFR mutations were simultaneously detected using an ADx-ARMS EGFR kit (Amoy Diagnostics CO., ltd., Xiamen, China) and an ADx-SuperARMS EGFR kit (Amoy Diagnostics CO., ltd., Xiamen, China). Digital droplet PCR (ddPCR) and next-generation sequencing (NGS) were further used to verify the EGFR mutant inconsistent samples. RESULTS: All of the 234 patients with advanced or recurrent NSCLC were diagnosed and assessed by two cytopathologists, and their EGFR mutation statuses were successfully detected by ARMS and SuperARMS. Importantly, the SuperARMS and ARMS methods showed a highly concordant result of 94.0% (220/234) (95%CI: 85.0, 95.0%). The positive rate of the SuperARMS was higher than the ARMS in the cytology samples for EGFR detection (46.2% vs. 40.2%). The specific EGFR mutation sites in 16 samples (6.8%) were not completely consistent between the SuperARMS and ARMS. A total of 14 patients showed EGFR mutations when detected by SuperARMS, but by ARMS there were EGFR wild-type. Two patients were detected as having one more EGFR mutation site by SuperARMS than by ARMS. ddPCR and NGS were used to further confirm the EGFR mutations in these inconsistent samples. Eight samples had the same mutation results as the SuperARMS, and 6 samples were not verified because the remaining DNA was insufficient. A total of 78 EGFR mutation patients received Tyrosine Kinase Inhibitor (TKI) treatment. The overall objective response rate (ORR) was 88.5% (69/78) for EGFR TKI treatment. CONCLUSION: SuperARMS showed a high sensitivity and specificity for EGFR detection and thus, is expected to become a routine test in the clinic to be used as a widely available, easy-to-operate and sensitive method for EGFR mutation detection in liquid-based cytology samples.
format Online
Article
Text
id pubmed-6995041
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-69950412020-02-04 Comparison of the SuperARMS and ARMS for detecting EGFR mutations in liquid-based cytology specimens from NSCLC patients Wu, Wei Cao, Ziyang Zhang, Wei Zhang, Liping Hou, Likun Wu, Chunyan Diagn Pathol Research BACKGROUND: Non-surgical cytological specimens are adequate not only for accurate histological subtyping but also for molecular profiling. A modified amplification refractory mutation system polymerase chain reaction (ARMS PCR), known as SuperARMS PCR, was improved by optimizing the primers designation, which provides a higher sensitivity and specificity approach for free plasma DNA detection. It is unclear whether SuperARMS PCR detects epidermal growth factor receptor (EGFR) mutations in cytology samples. The aim of this study was to compare the EGFR mutations detected by ARMS PCR and SuperARMS PCR in cytology samples derived from advanced non-small cell lung cancer (NSCLC) patients. METHODS: From March 2016 to March 2018, a total of 234 cytological samples were obtained from primary or metastatic lesions of NSCLC, including 144 fine-needle aspirations (FNAs), 36 endobroncheal ultrasonography (EBUS) FNAs, 36 transbronchial needle aspirations (TBNAs) and 18 pleural effusion (PLEs). EGFR mutations were simultaneously detected using an ADx-ARMS EGFR kit (Amoy Diagnostics CO., ltd., Xiamen, China) and an ADx-SuperARMS EGFR kit (Amoy Diagnostics CO., ltd., Xiamen, China). Digital droplet PCR (ddPCR) and next-generation sequencing (NGS) were further used to verify the EGFR mutant inconsistent samples. RESULTS: All of the 234 patients with advanced or recurrent NSCLC were diagnosed and assessed by two cytopathologists, and their EGFR mutation statuses were successfully detected by ARMS and SuperARMS. Importantly, the SuperARMS and ARMS methods showed a highly concordant result of 94.0% (220/234) (95%CI: 85.0, 95.0%). The positive rate of the SuperARMS was higher than the ARMS in the cytology samples for EGFR detection (46.2% vs. 40.2%). The specific EGFR mutation sites in 16 samples (6.8%) were not completely consistent between the SuperARMS and ARMS. A total of 14 patients showed EGFR mutations when detected by SuperARMS, but by ARMS there were EGFR wild-type. Two patients were detected as having one more EGFR mutation site by SuperARMS than by ARMS. ddPCR and NGS were used to further confirm the EGFR mutations in these inconsistent samples. Eight samples had the same mutation results as the SuperARMS, and 6 samples were not verified because the remaining DNA was insufficient. A total of 78 EGFR mutation patients received Tyrosine Kinase Inhibitor (TKI) treatment. The overall objective response rate (ORR) was 88.5% (69/78) for EGFR TKI treatment. CONCLUSION: SuperARMS showed a high sensitivity and specificity for EGFR detection and thus, is expected to become a routine test in the clinic to be used as a widely available, easy-to-operate and sensitive method for EGFR mutation detection in liquid-based cytology samples. BioMed Central 2020-01-31 /pmc/articles/PMC6995041/ /pubmed/32005253 http://dx.doi.org/10.1186/s13000-019-0910-5 Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Wu, Wei
Cao, Ziyang
Zhang, Wei
Zhang, Liping
Hou, Likun
Wu, Chunyan
Comparison of the SuperARMS and ARMS for detecting EGFR mutations in liquid-based cytology specimens from NSCLC patients
title Comparison of the SuperARMS and ARMS for detecting EGFR mutations in liquid-based cytology specimens from NSCLC patients
title_full Comparison of the SuperARMS and ARMS for detecting EGFR mutations in liquid-based cytology specimens from NSCLC patients
title_fullStr Comparison of the SuperARMS and ARMS for detecting EGFR mutations in liquid-based cytology specimens from NSCLC patients
title_full_unstemmed Comparison of the SuperARMS and ARMS for detecting EGFR mutations in liquid-based cytology specimens from NSCLC patients
title_short Comparison of the SuperARMS and ARMS for detecting EGFR mutations in liquid-based cytology specimens from NSCLC patients
title_sort comparison of the superarms and arms for detecting egfr mutations in liquid-based cytology specimens from nsclc patients
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6995041/
https://www.ncbi.nlm.nih.gov/pubmed/32005253
http://dx.doi.org/10.1186/s13000-019-0910-5
work_keys_str_mv AT wuwei comparisonofthesuperarmsandarmsfordetectingegfrmutationsinliquidbasedcytologyspecimensfromnsclcpatients
AT caoziyang comparisonofthesuperarmsandarmsfordetectingegfrmutationsinliquidbasedcytologyspecimensfromnsclcpatients
AT zhangwei comparisonofthesuperarmsandarmsfordetectingegfrmutationsinliquidbasedcytologyspecimensfromnsclcpatients
AT zhangliping comparisonofthesuperarmsandarmsfordetectingegfrmutationsinliquidbasedcytologyspecimensfromnsclcpatients
AT houlikun comparisonofthesuperarmsandarmsfordetectingegfrmutationsinliquidbasedcytologyspecimensfromnsclcpatients
AT wuchunyan comparisonofthesuperarmsandarmsfordetectingegfrmutationsinliquidbasedcytologyspecimensfromnsclcpatients