Cargando…

Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners

OBJECTIVE: The aim of this study was to compare the accuracy and reliability of measurements performed using two different software programs on digital models generated using two types of plaster model scanners (a laser scanner and a computed tomography [CT] scanner). METHODS: Thirty plaster models...

Descripción completa

Detalles Bibliográficos
Autores principales: Camardella, Leonardo T., Ongkosuwito, Edwin M., Penning, E. Willemijn, Kuijpers-Jagtman, Anne Marie, Vilella, Oswaldo V., Breuning, K. Hero
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Association of Orthodontists 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6995834/
https://www.ncbi.nlm.nih.gov/pubmed/32042716
http://dx.doi.org/10.4041/kjod.2020.50.1.13
_version_ 1783493440939491328
author Camardella, Leonardo T.
Ongkosuwito, Edwin M.
Penning, E. Willemijn
Kuijpers-Jagtman, Anne Marie
Vilella, Oswaldo V.
Breuning, K. Hero
author_facet Camardella, Leonardo T.
Ongkosuwito, Edwin M.
Penning, E. Willemijn
Kuijpers-Jagtman, Anne Marie
Vilella, Oswaldo V.
Breuning, K. Hero
author_sort Camardella, Leonardo T.
collection PubMed
description OBJECTIVE: The aim of this study was to compare the accuracy and reliability of measurements performed using two different software programs on digital models generated using two types of plaster model scanners (a laser scanner and a computed tomography [CT] scanner). METHODS: Thirty plaster models were scanned with a 3Shape laser scanner and with a Flash CT scanner. Two examiners performed measurements on plaster models by using digital calipers and on digital models by using Ortho Analyzer (3Shape) and Digimodel® (OrthoProof) software programs. Forty-two measurements, including tooth diameter, crown height, overjet, overbite, intercanine and intermolar distances, and sagittal relationship, were obtained. RESULTS: Statistically significant differences were not found between the plaster and digital model measurements (ANOVA); however, some discrepancies were clinically relevant. Plaster and digital model measurements made using the two scanning methods showed high intraclass coefficient correlation values and acceptable 95% limits of agreement in the Bland-Altman analysis. The software used did not influence the accuracy of measurements. CONCLUSIONS: Digital models generated from plaster casts by using laser and CT scanning and measured using two different software programs are accurate, and the measurements are reliable. Therefore, both fabrication methods and software could be used interchangeably.
format Online
Article
Text
id pubmed-6995834
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Association of Orthodontists
record_format MEDLINE/PubMed
spelling pubmed-69958342020-02-10 Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners Camardella, Leonardo T. Ongkosuwito, Edwin M. Penning, E. Willemijn Kuijpers-Jagtman, Anne Marie Vilella, Oswaldo V. Breuning, K. Hero Korean J Orthod Original Article OBJECTIVE: The aim of this study was to compare the accuracy and reliability of measurements performed using two different software programs on digital models generated using two types of plaster model scanners (a laser scanner and a computed tomography [CT] scanner). METHODS: Thirty plaster models were scanned with a 3Shape laser scanner and with a Flash CT scanner. Two examiners performed measurements on plaster models by using digital calipers and on digital models by using Ortho Analyzer (3Shape) and Digimodel® (OrthoProof) software programs. Forty-two measurements, including tooth diameter, crown height, overjet, overbite, intercanine and intermolar distances, and sagittal relationship, were obtained. RESULTS: Statistically significant differences were not found between the plaster and digital model measurements (ANOVA); however, some discrepancies were clinically relevant. Plaster and digital model measurements made using the two scanning methods showed high intraclass coefficient correlation values and acceptable 95% limits of agreement in the Bland-Altman analysis. The software used did not influence the accuracy of measurements. CONCLUSIONS: Digital models generated from plaster casts by using laser and CT scanning and measured using two different software programs are accurate, and the measurements are reliable. Therefore, both fabrication methods and software could be used interchangeably. Korean Association of Orthodontists 2020-01 2020-01-22 /pmc/articles/PMC6995834/ /pubmed/32042716 http://dx.doi.org/10.4041/kjod.2020.50.1.13 Text en © 2020 The Korean Association of Orthodontists. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Camardella, Leonardo T.
Ongkosuwito, Edwin M.
Penning, E. Willemijn
Kuijpers-Jagtman, Anne Marie
Vilella, Oswaldo V.
Breuning, K. Hero
Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners
title Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners
title_full Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners
title_fullStr Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners
title_full_unstemmed Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners
title_short Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners
title_sort accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6995834/
https://www.ncbi.nlm.nih.gov/pubmed/32042716
http://dx.doi.org/10.4041/kjod.2020.50.1.13
work_keys_str_mv AT camardellaleonardot accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners
AT ongkosuwitoedwinm accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners
AT penningewillemijn accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners
AT kuijpersjagtmanannemarie accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners
AT vilellaoswaldov accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners
AT breuningkhero accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners