Cargando…
Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners
OBJECTIVE: The aim of this study was to compare the accuracy and reliability of measurements performed using two different software programs on digital models generated using two types of plaster model scanners (a laser scanner and a computed tomography [CT] scanner). METHODS: Thirty plaster models...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Association of Orthodontists
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6995834/ https://www.ncbi.nlm.nih.gov/pubmed/32042716 http://dx.doi.org/10.4041/kjod.2020.50.1.13 |
_version_ | 1783493440939491328 |
---|---|
author | Camardella, Leonardo T. Ongkosuwito, Edwin M. Penning, E. Willemijn Kuijpers-Jagtman, Anne Marie Vilella, Oswaldo V. Breuning, K. Hero |
author_facet | Camardella, Leonardo T. Ongkosuwito, Edwin M. Penning, E. Willemijn Kuijpers-Jagtman, Anne Marie Vilella, Oswaldo V. Breuning, K. Hero |
author_sort | Camardella, Leonardo T. |
collection | PubMed |
description | OBJECTIVE: The aim of this study was to compare the accuracy and reliability of measurements performed using two different software programs on digital models generated using two types of plaster model scanners (a laser scanner and a computed tomography [CT] scanner). METHODS: Thirty plaster models were scanned with a 3Shape laser scanner and with a Flash CT scanner. Two examiners performed measurements on plaster models by using digital calipers and on digital models by using Ortho Analyzer (3Shape) and Digimodel® (OrthoProof) software programs. Forty-two measurements, including tooth diameter, crown height, overjet, overbite, intercanine and intermolar distances, and sagittal relationship, were obtained. RESULTS: Statistically significant differences were not found between the plaster and digital model measurements (ANOVA); however, some discrepancies were clinically relevant. Plaster and digital model measurements made using the two scanning methods showed high intraclass coefficient correlation values and acceptable 95% limits of agreement in the Bland-Altman analysis. The software used did not influence the accuracy of measurements. CONCLUSIONS: Digital models generated from plaster casts by using laser and CT scanning and measured using two different software programs are accurate, and the measurements are reliable. Therefore, both fabrication methods and software could be used interchangeably. |
format | Online Article Text |
id | pubmed-6995834 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Korean Association of Orthodontists |
record_format | MEDLINE/PubMed |
spelling | pubmed-69958342020-02-10 Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners Camardella, Leonardo T. Ongkosuwito, Edwin M. Penning, E. Willemijn Kuijpers-Jagtman, Anne Marie Vilella, Oswaldo V. Breuning, K. Hero Korean J Orthod Original Article OBJECTIVE: The aim of this study was to compare the accuracy and reliability of measurements performed using two different software programs on digital models generated using two types of plaster model scanners (a laser scanner and a computed tomography [CT] scanner). METHODS: Thirty plaster models were scanned with a 3Shape laser scanner and with a Flash CT scanner. Two examiners performed measurements on plaster models by using digital calipers and on digital models by using Ortho Analyzer (3Shape) and Digimodel® (OrthoProof) software programs. Forty-two measurements, including tooth diameter, crown height, overjet, overbite, intercanine and intermolar distances, and sagittal relationship, were obtained. RESULTS: Statistically significant differences were not found between the plaster and digital model measurements (ANOVA); however, some discrepancies were clinically relevant. Plaster and digital model measurements made using the two scanning methods showed high intraclass coefficient correlation values and acceptable 95% limits of agreement in the Bland-Altman analysis. The software used did not influence the accuracy of measurements. CONCLUSIONS: Digital models generated from plaster casts by using laser and CT scanning and measured using two different software programs are accurate, and the measurements are reliable. Therefore, both fabrication methods and software could be used interchangeably. Korean Association of Orthodontists 2020-01 2020-01-22 /pmc/articles/PMC6995834/ /pubmed/32042716 http://dx.doi.org/10.4041/kjod.2020.50.1.13 Text en © 2020 The Korean Association of Orthodontists. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Camardella, Leonardo T. Ongkosuwito, Edwin M. Penning, E. Willemijn Kuijpers-Jagtman, Anne Marie Vilella, Oswaldo V. Breuning, K. Hero Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners |
title | Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners |
title_full | Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners |
title_fullStr | Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners |
title_full_unstemmed | Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners |
title_short | Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners |
title_sort | accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6995834/ https://www.ncbi.nlm.nih.gov/pubmed/32042716 http://dx.doi.org/10.4041/kjod.2020.50.1.13 |
work_keys_str_mv | AT camardellaleonardot accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners AT ongkosuwitoedwinm accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners AT penningewillemijn accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners AT kuijpersjagtmanannemarie accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners AT vilellaoswaldov accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners AT breuningkhero accuracyandreliabilityofmeasurementsperformedusingtwodifferentsoftwareprogramsondigitalmodelsgeneratedusinglaserandcomputedtomographyplastermodelscanners |