Cargando…
Review of methods and applications of attenuation coefficient measurements with optical coherence tomography
The optical attenuation coefficient (AC), an important tissue parameter that measures how quickly incident light is attenuated when passing through a medium, has been shown to enable quantitative analysis of tissue properties from optical coherence tomography (OCT) signals. Successful extraction of...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6997582/ https://www.ncbi.nlm.nih.gov/pubmed/31520468 http://dx.doi.org/10.1117/1.JBO.24.9.090901 |
_version_ | 1783493732008460288 |
---|---|
author | Chang, Shuang Bowden, Audrey K. |
author_facet | Chang, Shuang Bowden, Audrey K. |
author_sort | Chang, Shuang |
collection | PubMed |
description | The optical attenuation coefficient (AC), an important tissue parameter that measures how quickly incident light is attenuated when passing through a medium, has been shown to enable quantitative analysis of tissue properties from optical coherence tomography (OCT) signals. Successful extraction of this parameter would facilitate tissue differentiation and enhance the diagnostic value of OCT. In this review, we discuss the physical and mathematical basis of AC extraction from OCT data, including current approaches used in modeling light scattering in tissue and in AC estimation. We also report on demonstrated clinical applications of the AC, such as for atherosclerotic tissue characterization, malignant lesion detection, and brain injury visualization. With current studies showing AC analysis as a promising technique, further efforts in the development of methods to accurately extract the AC and to explore its potential use for more extensive clinical applications are desired. |
format | Online Article Text |
id | pubmed-6997582 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-69975822020-02-10 Review of methods and applications of attenuation coefficient measurements with optical coherence tomography Chang, Shuang Bowden, Audrey K. J Biomed Opt Review Papers The optical attenuation coefficient (AC), an important tissue parameter that measures how quickly incident light is attenuated when passing through a medium, has been shown to enable quantitative analysis of tissue properties from optical coherence tomography (OCT) signals. Successful extraction of this parameter would facilitate tissue differentiation and enhance the diagnostic value of OCT. In this review, we discuss the physical and mathematical basis of AC extraction from OCT data, including current approaches used in modeling light scattering in tissue and in AC estimation. We also report on demonstrated clinical applications of the AC, such as for atherosclerotic tissue characterization, malignant lesion detection, and brain injury visualization. With current studies showing AC analysis as a promising technique, further efforts in the development of methods to accurately extract the AC and to explore its potential use for more extensive clinical applications are desired. Society of Photo-Optical Instrumentation Engineers 2019-09-13 2019-09 /pmc/articles/PMC6997582/ /pubmed/31520468 http://dx.doi.org/10.1117/1.JBO.24.9.090901 Text en © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Review Papers Chang, Shuang Bowden, Audrey K. Review of methods and applications of attenuation coefficient measurements with optical coherence tomography |
title | Review of methods and applications of attenuation coefficient measurements with optical coherence tomography |
title_full | Review of methods and applications of attenuation coefficient measurements with optical coherence tomography |
title_fullStr | Review of methods and applications of attenuation coefficient measurements with optical coherence tomography |
title_full_unstemmed | Review of methods and applications of attenuation coefficient measurements with optical coherence tomography |
title_short | Review of methods and applications of attenuation coefficient measurements with optical coherence tomography |
title_sort | review of methods and applications of attenuation coefficient measurements with optical coherence tomography |
topic | Review Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6997582/ https://www.ncbi.nlm.nih.gov/pubmed/31520468 http://dx.doi.org/10.1117/1.JBO.24.9.090901 |
work_keys_str_mv | AT changshuang reviewofmethodsandapplicationsofattenuationcoefficientmeasurementswithopticalcoherencetomography AT bowdenaudreyk reviewofmethodsandapplicationsofattenuationcoefficientmeasurementswithopticalcoherencetomography |