Cargando…

Review of methods and applications of attenuation coefficient measurements with optical coherence tomography

The optical attenuation coefficient (AC), an important tissue parameter that measures how quickly incident light is attenuated when passing through a medium, has been shown to enable quantitative analysis of tissue properties from optical coherence tomography (OCT) signals. Successful extraction of...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Shuang, Bowden, Audrey K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6997582/
https://www.ncbi.nlm.nih.gov/pubmed/31520468
http://dx.doi.org/10.1117/1.JBO.24.9.090901
_version_ 1783493732008460288
author Chang, Shuang
Bowden, Audrey K.
author_facet Chang, Shuang
Bowden, Audrey K.
author_sort Chang, Shuang
collection PubMed
description The optical attenuation coefficient (AC), an important tissue parameter that measures how quickly incident light is attenuated when passing through a medium, has been shown to enable quantitative analysis of tissue properties from optical coherence tomography (OCT) signals. Successful extraction of this parameter would facilitate tissue differentiation and enhance the diagnostic value of OCT. In this review, we discuss the physical and mathematical basis of AC extraction from OCT data, including current approaches used in modeling light scattering in tissue and in AC estimation. We also report on demonstrated clinical applications of the AC, such as for atherosclerotic tissue characterization, malignant lesion detection, and brain injury visualization. With current studies showing AC analysis as a promising technique, further efforts in the development of methods to accurately extract the AC and to explore its potential use for more extensive clinical applications are desired.
format Online
Article
Text
id pubmed-6997582
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-69975822020-02-10 Review of methods and applications of attenuation coefficient measurements with optical coherence tomography Chang, Shuang Bowden, Audrey K. J Biomed Opt Review Papers The optical attenuation coefficient (AC), an important tissue parameter that measures how quickly incident light is attenuated when passing through a medium, has been shown to enable quantitative analysis of tissue properties from optical coherence tomography (OCT) signals. Successful extraction of this parameter would facilitate tissue differentiation and enhance the diagnostic value of OCT. In this review, we discuss the physical and mathematical basis of AC extraction from OCT data, including current approaches used in modeling light scattering in tissue and in AC estimation. We also report on demonstrated clinical applications of the AC, such as for atherosclerotic tissue characterization, malignant lesion detection, and brain injury visualization. With current studies showing AC analysis as a promising technique, further efforts in the development of methods to accurately extract the AC and to explore its potential use for more extensive clinical applications are desired. Society of Photo-Optical Instrumentation Engineers 2019-09-13 2019-09 /pmc/articles/PMC6997582/ /pubmed/31520468 http://dx.doi.org/10.1117/1.JBO.24.9.090901 Text en © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Review Papers
Chang, Shuang
Bowden, Audrey K.
Review of methods and applications of attenuation coefficient measurements with optical coherence tomography
title Review of methods and applications of attenuation coefficient measurements with optical coherence tomography
title_full Review of methods and applications of attenuation coefficient measurements with optical coherence tomography
title_fullStr Review of methods and applications of attenuation coefficient measurements with optical coherence tomography
title_full_unstemmed Review of methods and applications of attenuation coefficient measurements with optical coherence tomography
title_short Review of methods and applications of attenuation coefficient measurements with optical coherence tomography
title_sort review of methods and applications of attenuation coefficient measurements with optical coherence tomography
topic Review Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6997582/
https://www.ncbi.nlm.nih.gov/pubmed/31520468
http://dx.doi.org/10.1117/1.JBO.24.9.090901
work_keys_str_mv AT changshuang reviewofmethodsandapplicationsofattenuationcoefficientmeasurementswithopticalcoherencetomography
AT bowdenaudreyk reviewofmethodsandapplicationsofattenuationcoefficientmeasurementswithopticalcoherencetomography