Cargando…

Delayed Aortic Stent Collapse in Blunt Traumatic Aortic Injury Repair

Background  Endovascular stent grafting has emerged as an option to treat traumatic aorta injuries with reported significantly low mortality and morbidity. Stent collapse is one of the complications that can occur in this type of treatment. The aim of this article is to analyze the expected cause of...

Descripción completa

Detalles Bibliográficos
Autores principales: Alhaizaey, Abdullah, Aljabri, Badr, Alghamdi, Musaad, AlAhmari, Ali, Abulyazied, Ahmed, Asiry, Mohammed, Al-Omran, Mohammed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical Publishers 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7000265/
https://www.ncbi.nlm.nih.gov/pubmed/32018308
http://dx.doi.org/10.1055/s-0039-3401022
_version_ 1783494006117761024
author Alhaizaey, Abdullah
Aljabri, Badr
Alghamdi, Musaad
AlAhmari, Ali
Abulyazied, Ahmed
Asiry, Mohammed
Al-Omran, Mohammed
author_facet Alhaizaey, Abdullah
Aljabri, Badr
Alghamdi, Musaad
AlAhmari, Ali
Abulyazied, Ahmed
Asiry, Mohammed
Al-Omran, Mohammed
author_sort Alhaizaey, Abdullah
collection PubMed
description Background  Endovascular stent grafting has emerged as an option to treat traumatic aorta injuries with reported significantly low mortality and morbidity. Stent collapse is one of the complications that can occur in this type of treatment. The aim of this article is to analyze the expected cause of stent collapse and to draw attention to the importance of the surveillance follow-up, as this phenomenon may occur late postdeployment. Methods  A retrospectively collected dataset from the two highest volume trauma centers in Saudi Arabia was analyzed between April 2007 and October 2012. A total of 66 patients received stent grafts for traumatic aortic injury and were included in the study. We apply Ishimaru's anatomical aortic arch zones and Benjamin's aortic injury grading systems. There were 35 patients with aortic injury at zone 2, 26 patients in zone 3, and 5 patients in zone 4. About 96% (63) of the injuries were grades 2 and 3, including large intimal flap or aortic wall pseudoaneurysm with change in wall contour. The technical success rate, as defined by complete exclusion of lesions without leaks, stroke, arm ischemia or stent-related complications, was 90%. Results  Proximal stent collapse occurred in 4.5% of patients (3 of 66 inserted stents) during follow-up of 4 to 8 years (mean, 6 years). Patients with stent collapse tended to have an acute aortic arch angle with long-intraluminal stent lip, when compared with patients with noncollapsed stents. Intraluminal lip protrusion more than 10-mm increased collapse ( p  < 0.001). Stent-grafts sizes larger than 28 mm also demonstrated a higher collapse rate ( p  < 0.001). Conclusions  The risk of stent collapse appears related to poor apposition of the stent due to severe aortic arch angulation in young patients and to large stent sizes (>28 mm). Such age groups may have more anatomical and aortic size changes during the growth. Clinical and radiological surveillance is essential in follow-up after stent-graft treatment for traumatic aortic injury.
format Online
Article
Text
id pubmed-7000265
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Thieme Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-70002652020-02-05 Delayed Aortic Stent Collapse in Blunt Traumatic Aortic Injury Repair Alhaizaey, Abdullah Aljabri, Badr Alghamdi, Musaad AlAhmari, Ali Abulyazied, Ahmed Asiry, Mohammed Al-Omran, Mohammed Aorta (Stamford) Background  Endovascular stent grafting has emerged as an option to treat traumatic aorta injuries with reported significantly low mortality and morbidity. Stent collapse is one of the complications that can occur in this type of treatment. The aim of this article is to analyze the expected cause of stent collapse and to draw attention to the importance of the surveillance follow-up, as this phenomenon may occur late postdeployment. Methods  A retrospectively collected dataset from the two highest volume trauma centers in Saudi Arabia was analyzed between April 2007 and October 2012. A total of 66 patients received stent grafts for traumatic aortic injury and were included in the study. We apply Ishimaru's anatomical aortic arch zones and Benjamin's aortic injury grading systems. There were 35 patients with aortic injury at zone 2, 26 patients in zone 3, and 5 patients in zone 4. About 96% (63) of the injuries were grades 2 and 3, including large intimal flap or aortic wall pseudoaneurysm with change in wall contour. The technical success rate, as defined by complete exclusion of lesions without leaks, stroke, arm ischemia or stent-related complications, was 90%. Results  Proximal stent collapse occurred in 4.5% of patients (3 of 66 inserted stents) during follow-up of 4 to 8 years (mean, 6 years). Patients with stent collapse tended to have an acute aortic arch angle with long-intraluminal stent lip, when compared with patients with noncollapsed stents. Intraluminal lip protrusion more than 10-mm increased collapse ( p  < 0.001). Stent-grafts sizes larger than 28 mm also demonstrated a higher collapse rate ( p  < 0.001). Conclusions  The risk of stent collapse appears related to poor apposition of the stent due to severe aortic arch angulation in young patients and to large stent sizes (>28 mm). Such age groups may have more anatomical and aortic size changes during the growth. Clinical and radiological surveillance is essential in follow-up after stent-graft treatment for traumatic aortic injury. Thieme Medical Publishers 2020-02-04 /pmc/articles/PMC7000265/ /pubmed/32018308 http://dx.doi.org/10.1055/s-0039-3401022 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Alhaizaey, Abdullah
Aljabri, Badr
Alghamdi, Musaad
AlAhmari, Ali
Abulyazied, Ahmed
Asiry, Mohammed
Al-Omran, Mohammed
Delayed Aortic Stent Collapse in Blunt Traumatic Aortic Injury Repair
title Delayed Aortic Stent Collapse in Blunt Traumatic Aortic Injury Repair
title_full Delayed Aortic Stent Collapse in Blunt Traumatic Aortic Injury Repair
title_fullStr Delayed Aortic Stent Collapse in Blunt Traumatic Aortic Injury Repair
title_full_unstemmed Delayed Aortic Stent Collapse in Blunt Traumatic Aortic Injury Repair
title_short Delayed Aortic Stent Collapse in Blunt Traumatic Aortic Injury Repair
title_sort delayed aortic stent collapse in blunt traumatic aortic injury repair
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7000265/
https://www.ncbi.nlm.nih.gov/pubmed/32018308
http://dx.doi.org/10.1055/s-0039-3401022
work_keys_str_mv AT alhaizaeyabdullah delayedaorticstentcollapseinblunttraumaticaorticinjuryrepair
AT aljabribadr delayedaorticstentcollapseinblunttraumaticaorticinjuryrepair
AT alghamdimusaad delayedaorticstentcollapseinblunttraumaticaorticinjuryrepair
AT alahmariali delayedaorticstentcollapseinblunttraumaticaorticinjuryrepair
AT abulyaziedahmed delayedaorticstentcollapseinblunttraumaticaorticinjuryrepair
AT asirymohammed delayedaorticstentcollapseinblunttraumaticaorticinjuryrepair
AT alomranmohammed delayedaorticstentcollapseinblunttraumaticaorticinjuryrepair