Cargando…
Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution
Proper pedicle screw placement is an integral part of spine fusion requiring expertly trained spine surgeons. Advances in medical imaging guidance have improved accuracy. There is high interest in the emerging field of robot-assisted spine surgery; however, safety and accuracy studies are needed. Th...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer London
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7000538/ https://www.ncbi.nlm.nih.gov/pubmed/31016575 http://dx.doi.org/10.1007/s11701-019-00959-6 |
_version_ | 1783494064243474432 |
---|---|
author | Huntsman, Kade T. Ahrendtsen, Leigh A. Riggleman, Jessica R. Ledonio, Charles G. |
author_facet | Huntsman, Kade T. Ahrendtsen, Leigh A. Riggleman, Jessica R. Ledonio, Charles G. |
author_sort | Huntsman, Kade T. |
collection | PubMed |
description | Proper pedicle screw placement is an integral part of spine fusion requiring expertly trained spine surgeons. Advances in medical imaging guidance have improved accuracy. There is high interest in the emerging field of robot-assisted spine surgery; however, safety and accuracy studies are needed. This study describes the pedicle screw placement of the first 100 cases in which navigated robotic assistance was used in a private practice clinical setting. A single-surgeon, single-site retrospective Institutional Review Board-exempt review of the first 100 navigated robot-assisted spine surgery cases was performed. An orthopaedic surgeon evaluated screw placement using plain film radiographs. In addition, pedicle screw malposition, reposition, and return to operating room (OR) rates were collected. Results demonstrated a high level (99%) of successful surgeon assessed pedicle screw placement in minimally invasive navigated robot-assisted spine surgery, with no malpositions requiring return to the OR. |
format | Online Article Text |
id | pubmed-7000538 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer London |
record_format | MEDLINE/PubMed |
spelling | pubmed-70005382020-02-21 Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution Huntsman, Kade T. Ahrendtsen, Leigh A. Riggleman, Jessica R. Ledonio, Charles G. J Robot Surg Original Article Proper pedicle screw placement is an integral part of spine fusion requiring expertly trained spine surgeons. Advances in medical imaging guidance have improved accuracy. There is high interest in the emerging field of robot-assisted spine surgery; however, safety and accuracy studies are needed. This study describes the pedicle screw placement of the first 100 cases in which navigated robotic assistance was used in a private practice clinical setting. A single-surgeon, single-site retrospective Institutional Review Board-exempt review of the first 100 navigated robot-assisted spine surgery cases was performed. An orthopaedic surgeon evaluated screw placement using plain film radiographs. In addition, pedicle screw malposition, reposition, and return to operating room (OR) rates were collected. Results demonstrated a high level (99%) of successful surgeon assessed pedicle screw placement in minimally invasive navigated robot-assisted spine surgery, with no malpositions requiring return to the OR. Springer London 2019-04-23 2020 /pmc/articles/PMC7000538/ /pubmed/31016575 http://dx.doi.org/10.1007/s11701-019-00959-6 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Huntsman, Kade T. Ahrendtsen, Leigh A. Riggleman, Jessica R. Ledonio, Charles G. Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution |
title | Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution |
title_full | Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution |
title_fullStr | Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution |
title_full_unstemmed | Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution |
title_short | Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution |
title_sort | robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7000538/ https://www.ncbi.nlm.nih.gov/pubmed/31016575 http://dx.doi.org/10.1007/s11701-019-00959-6 |
work_keys_str_mv | AT huntsmankadet roboticassistednavigatedminimallyinvasivepediclescrewplacementinthefirst100casesatasingleinstitution AT ahrendtsenleigha roboticassistednavigatedminimallyinvasivepediclescrewplacementinthefirst100casesatasingleinstitution AT rigglemanjessicar roboticassistednavigatedminimallyinvasivepediclescrewplacementinthefirst100casesatasingleinstitution AT ledoniocharlesg roboticassistednavigatedminimallyinvasivepediclescrewplacementinthefirst100casesatasingleinstitution |