Cargando…

Bond strength of locator housing attached to denture base resin secured with different retaining materials

BACKGROUND: The type of housing retaining material may affect the bond strength of the housing to denture base resin. The aim of this in vitro study was to evaluate the bond strength of locator housing attached to polymethyl methacrylate (PMMA) denture base resin secured with different retaining mat...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakhaei, Mohammadreza, Dashti, Hossin, Baghbani, Atefe, Ahmadi, Zahra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7001568/
https://www.ncbi.nlm.nih.gov/pubmed/32055291
_version_ 1783494268505030656
author Nakhaei, Mohammadreza
Dashti, Hossin
Baghbani, Atefe
Ahmadi, Zahra
author_facet Nakhaei, Mohammadreza
Dashti, Hossin
Baghbani, Atefe
Ahmadi, Zahra
author_sort Nakhaei, Mohammadreza
collection PubMed
description BACKGROUND: The type of housing retaining material may affect the bond strength of the housing to denture base resin. The aim of this in vitro study was to evaluate the bond strength of locator housing attached to polymethyl methacrylate (PMMA) denture base resin secured with different retaining materials. MATERIALS AND METHODS: In this in vitro study Forty-four PMMA blocks (10 mm × 15 mm × 15 mm) were prepared with a central cylindrical canal inside to allow the insertion of locator housings. The prepared specimens were then randomly divided into four groups (n = 11). Each group received one of the following retaining materials for housing insertion: Auto-polymerized acrylic resin (APAR), auto-polymerized composite resin (Quick up), application of alloy primer on titanium housing plus Quick up (AL-Quick), and heat-polymerized acrylic resin (HPAR). The specimens were thermocycled 5000 times between 5°C and 55°C, followed by 1000 cycles of vertical insertion separation on the locator abutment. A push-out force was applied on the flat back surface of the housing after which the failure and shear bond strength values were calculated. The data were analyzed using one way-ANOVA and Games-Howell test (α = 0.05). RESULTS: HPAR group had significantly higher shear bond strength values compared to the other groups (P < 0.05). No significant differences were found among the other remaining material groups (P > 0.05). CONCLUSION: Inserting of locator housing using HPAR resulted in higher bond strength between housing and denture base resin. The application of alloy primer did not improve the bond strength of locator housing which was retained with “Quick up”.
format Online
Article
Text
id pubmed-7001568
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-70015682020-02-13 Bond strength of locator housing attached to denture base resin secured with different retaining materials Nakhaei, Mohammadreza Dashti, Hossin Baghbani, Atefe Ahmadi, Zahra Dent Res J (Isfahan) Original Article BACKGROUND: The type of housing retaining material may affect the bond strength of the housing to denture base resin. The aim of this in vitro study was to evaluate the bond strength of locator housing attached to polymethyl methacrylate (PMMA) denture base resin secured with different retaining materials. MATERIALS AND METHODS: In this in vitro study Forty-four PMMA blocks (10 mm × 15 mm × 15 mm) were prepared with a central cylindrical canal inside to allow the insertion of locator housings. The prepared specimens were then randomly divided into four groups (n = 11). Each group received one of the following retaining materials for housing insertion: Auto-polymerized acrylic resin (APAR), auto-polymerized composite resin (Quick up), application of alloy primer on titanium housing plus Quick up (AL-Quick), and heat-polymerized acrylic resin (HPAR). The specimens were thermocycled 5000 times between 5°C and 55°C, followed by 1000 cycles of vertical insertion separation on the locator abutment. A push-out force was applied on the flat back surface of the housing after which the failure and shear bond strength values were calculated. The data were analyzed using one way-ANOVA and Games-Howell test (α = 0.05). RESULTS: HPAR group had significantly higher shear bond strength values compared to the other groups (P < 0.05). No significant differences were found among the other remaining material groups (P > 0.05). CONCLUSION: Inserting of locator housing using HPAR resulted in higher bond strength between housing and denture base resin. The application of alloy primer did not improve the bond strength of locator housing which was retained with “Quick up”. Wolters Kluwer - Medknow 2020-01-21 /pmc/articles/PMC7001568/ /pubmed/32055291 Text en Copyright: © 2020 Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Nakhaei, Mohammadreza
Dashti, Hossin
Baghbani, Atefe
Ahmadi, Zahra
Bond strength of locator housing attached to denture base resin secured with different retaining materials
title Bond strength of locator housing attached to denture base resin secured with different retaining materials
title_full Bond strength of locator housing attached to denture base resin secured with different retaining materials
title_fullStr Bond strength of locator housing attached to denture base resin secured with different retaining materials
title_full_unstemmed Bond strength of locator housing attached to denture base resin secured with different retaining materials
title_short Bond strength of locator housing attached to denture base resin secured with different retaining materials
title_sort bond strength of locator housing attached to denture base resin secured with different retaining materials
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7001568/
https://www.ncbi.nlm.nih.gov/pubmed/32055291
work_keys_str_mv AT nakhaeimohammadreza bondstrengthoflocatorhousingattachedtodenturebaseresinsecuredwithdifferentretainingmaterials
AT dashtihossin bondstrengthoflocatorhousingattachedtodenturebaseresinsecuredwithdifferentretainingmaterials
AT baghbaniatefe bondstrengthoflocatorhousingattachedtodenturebaseresinsecuredwithdifferentretainingmaterials
AT ahmadizahra bondstrengthoflocatorhousingattachedtodenturebaseresinsecuredwithdifferentretainingmaterials