Cargando…

3D Whole‐heart free‐breathing qBOOST‐T2 mapping

PURPOSE: To develop an accelerated motion corrected 3D whole‐heart imaging approach (qBOOST‐T2) for simultaneous high‐resolution bright‐ and black‐blood cardiac MR imaging and quantitative myocardial T2 characterization. METHODS: Three undersampled interleaved balanced steady‐state free precession c...

Descripción completa

Detalles Bibliográficos
Autores principales: Milotta, Giorgia, Ginami, Giulia, Bustin, Aurelien, Neji, Radhouene, Prieto, Claudia, Botnar, René M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7004111/
https://www.ncbi.nlm.nih.gov/pubmed/31631378
http://dx.doi.org/10.1002/mrm.28039
_version_ 1783494664642363392
author Milotta, Giorgia
Ginami, Giulia
Bustin, Aurelien
Neji, Radhouene
Prieto, Claudia
Botnar, René M.
author_facet Milotta, Giorgia
Ginami, Giulia
Bustin, Aurelien
Neji, Radhouene
Prieto, Claudia
Botnar, René M.
author_sort Milotta, Giorgia
collection PubMed
description PURPOSE: To develop an accelerated motion corrected 3D whole‐heart imaging approach (qBOOST‐T2) for simultaneous high‐resolution bright‐ and black‐blood cardiac MR imaging and quantitative myocardial T2 characterization. METHODS: Three undersampled interleaved balanced steady‐state free precession cardiac MR volumes were acquired with a variable density Cartesian trajectory and different magnetization preparations: (1) T2‐prepared inversion recovery (T2prep‐IR), (2) T2‐preparation, and (3) no preparation. Image navigators were acquired prior the acquisition to correct for 2D translational respiratory motion. Each 3D volume was reconstructed with a low‐rank patch‐based reconstruction. The T2prep‐IR volume provides bright‐blood anatomy visualization, the black‐blood volume is obtained by means of phase sensitive reconstruction between first and third datasets, and T2 maps are generated by matching the signal evolution to a simulated dictionary. The proposed sequence has been evaluated in simulations, phantom experiments, 11 healthy subjects and compared with 3D bright‐blood cardiac MR and standard 2D breath‐hold balanced steady‐state free precession T2 mapping. The feasibility of the proposed approach was tested on 4 patients with suspected cardiovascular disease. RESULTS: High linear correlation (y = 1.09 × −0.83, R(2) = 0.99) was found between the proposed qBOOST‐T2 and T2 spin echo measurements in phantom experiment. Good image quality was observed in vivo with the proposed 4x undersampled qBOOST‐T2. Mean T2 values of 53.1 ± 2.1 ms and 55.8 ± 2.7 ms were measured in vivo for 2D balanced steady‐state free precession T2 mapping and qBOOST‐T2, respectively, with linear correlation of y = 1.02x+1.46 (R(2) = 0.61) and T2 bias = 2.7 ms. CONCLUSION: The proposed qBOOST‐T2 sequence allows the acquisition of 3D high‐resolution co‐registered bright‐ and black‐blood volumes and T2 maps in a single scan of ~11 min, showing promising results in terms of T2 quantification.
format Online
Article
Text
id pubmed-7004111
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-70041112020-02-11 3D Whole‐heart free‐breathing qBOOST‐T2 mapping Milotta, Giorgia Ginami, Giulia Bustin, Aurelien Neji, Radhouene Prieto, Claudia Botnar, René M. Magn Reson Med Full Papers—Imaging Methodology PURPOSE: To develop an accelerated motion corrected 3D whole‐heart imaging approach (qBOOST‐T2) for simultaneous high‐resolution bright‐ and black‐blood cardiac MR imaging and quantitative myocardial T2 characterization. METHODS: Three undersampled interleaved balanced steady‐state free precession cardiac MR volumes were acquired with a variable density Cartesian trajectory and different magnetization preparations: (1) T2‐prepared inversion recovery (T2prep‐IR), (2) T2‐preparation, and (3) no preparation. Image navigators were acquired prior the acquisition to correct for 2D translational respiratory motion. Each 3D volume was reconstructed with a low‐rank patch‐based reconstruction. The T2prep‐IR volume provides bright‐blood anatomy visualization, the black‐blood volume is obtained by means of phase sensitive reconstruction between first and third datasets, and T2 maps are generated by matching the signal evolution to a simulated dictionary. The proposed sequence has been evaluated in simulations, phantom experiments, 11 healthy subjects and compared with 3D bright‐blood cardiac MR and standard 2D breath‐hold balanced steady‐state free precession T2 mapping. The feasibility of the proposed approach was tested on 4 patients with suspected cardiovascular disease. RESULTS: High linear correlation (y = 1.09 × −0.83, R(2) = 0.99) was found between the proposed qBOOST‐T2 and T2 spin echo measurements in phantom experiment. Good image quality was observed in vivo with the proposed 4x undersampled qBOOST‐T2. Mean T2 values of 53.1 ± 2.1 ms and 55.8 ± 2.7 ms were measured in vivo for 2D balanced steady‐state free precession T2 mapping and qBOOST‐T2, respectively, with linear correlation of y = 1.02x+1.46 (R(2) = 0.61) and T2 bias = 2.7 ms. CONCLUSION: The proposed qBOOST‐T2 sequence allows the acquisition of 3D high‐resolution co‐registered bright‐ and black‐blood volumes and T2 maps in a single scan of ~11 min, showing promising results in terms of T2 quantification. John Wiley and Sons Inc. 2019-10-21 2020-05 /pmc/articles/PMC7004111/ /pubmed/31631378 http://dx.doi.org/10.1002/mrm.28039 Text en © 2019 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Papers—Imaging Methodology
Milotta, Giorgia
Ginami, Giulia
Bustin, Aurelien
Neji, Radhouene
Prieto, Claudia
Botnar, René M.
3D Whole‐heart free‐breathing qBOOST‐T2 mapping
title 3D Whole‐heart free‐breathing qBOOST‐T2 mapping
title_full 3D Whole‐heart free‐breathing qBOOST‐T2 mapping
title_fullStr 3D Whole‐heart free‐breathing qBOOST‐T2 mapping
title_full_unstemmed 3D Whole‐heart free‐breathing qBOOST‐T2 mapping
title_short 3D Whole‐heart free‐breathing qBOOST‐T2 mapping
title_sort 3d whole‐heart free‐breathing qboost‐t2 mapping
topic Full Papers—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7004111/
https://www.ncbi.nlm.nih.gov/pubmed/31631378
http://dx.doi.org/10.1002/mrm.28039
work_keys_str_mv AT milottagiorgia 3dwholeheartfreebreathingqboostt2mapping
AT ginamigiulia 3dwholeheartfreebreathingqboostt2mapping
AT bustinaurelien 3dwholeheartfreebreathingqboostt2mapping
AT nejiradhouene 3dwholeheartfreebreathingqboostt2mapping
AT prietoclaudia 3dwholeheartfreebreathingqboostt2mapping
AT botnarrenem 3dwholeheartfreebreathingqboostt2mapping