Cargando…

Accuracy of Software-Based Three-Dimensional Root Canal Length Measurements Using Cone-Beam Computed Tomography

OBJECTIVE: This study aims to evaluate the accuracy of three-dimensional root canal length measurements performed by dentists with different experience levels using a special software based on cone beam com-puted tomography (CBCT). METHODS: A CBCT scan of an artificial resin maxillary molar was used...

Descripción completa

Detalles Bibliográficos
Autores principales: Tchorz, JP, Wrbas, KT, Von See, C, Vach, K, Patzelt, SBM
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kare Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7006557/
https://www.ncbi.nlm.nih.gov/pubmed/32161883
http://dx.doi.org/10.14744/eej.2018.46320
Descripción
Sumario:OBJECTIVE: This study aims to evaluate the accuracy of three-dimensional root canal length measurements performed by dentists with different experience levels using a special software based on cone beam com-puted tomography (CBCT). METHODS: A CBCT scan of an artificial resin maxillary molar was used to train dentists (n=65) in using the software (3D Endo, DentsplySirona, Ballaigues, Switzerland) as part of a continuing education course. At the beginning, each participant completed a questionnaire on endodontic and CBCT experiences. After com-prehensive instructions, each participant performed an entire three-dimensional treatment plan by tracing the root canal anatomy between the apical foramen and the center of the canal orifice and simulating a straight-line access. The final root canal length was indicated after the virtual rubber stop of a simulated instrument was adapted to the adjoining cusp. To evaluate the individual accuracy in terms of trueness and precision, differences between the three-dimensional planning and the actual root canal length (ARCL) were calculated, and statistically analyzed. RESULTS: Mean absolute differences between the measurements with the 3D Endo™ software (n=260) and the ARCL were 0.30±0.22 mm. All measurements were within a limit of ±1 mm. The accuracy of root canal length measurements was significantly influenced by the type of root canal (p<0.0001). The smallest devia-tions were observed for the palatal root canal (0.18±0.13 mm), followed by the mesiobuccal (0.26±0.22 mm), the distobuccal (0.32±0.17 mm), and the second mesiobuccal root canal (0.46±0.24 mm). CONCLUSION: Within the limitations of this study, the 3D Endo software enables reproducible and accurate root canal length measurements as part of a three-dimensional endodontic treatment plan. However, mea-surements should always be clinically verified, as root canal morphology has a statistically significant influence.