Cargando…
Comparison of Clinical Outcomes, Radiological Outcomes and Bone Remodeling Outcomes Between Proximal Coated Single-Wedge New Stem and Full Coated Dual-Wedge Classic Stem in 1-Stage Bilateral Total Hip Arthroplasty
BACKGROUND: This retrospective study investigated the clinical outcomes, radiological outcomes, and bone remodeling patterns associated with a Medial/Lateral Taper (M/L Taper) stem and Link Classic Uncemented (LCU) stem in 1-stage bilateral total hip arthroplasty (THA). MATERIAL/METHODS: The results...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7006600/ https://www.ncbi.nlm.nih.gov/pubmed/32001666 http://dx.doi.org/10.12659/MSM.921847 |
Sumario: | BACKGROUND: This retrospective study investigated the clinical outcomes, radiological outcomes, and bone remodeling patterns associated with a Medial/Lateral Taper (M/L Taper) stem and Link Classic Uncemented (LCU) stem in 1-stage bilateral total hip arthroplasty (THA). MATERIAL/METHODS: The results of 52 patients who underwent 1-stage bilateral THA with a M/L Taper stem on one side and an LCU stem on the other between January 2012 and February 2015 were retrospectively compared. Patients were clinically assessed by the Harris hip score (HHS), visual analogue score (VAS) and incidence of complications. Radiological indicators were measured. Periprosthetic bone remodeling was assessed via bone mineral density (BMD) measurements. RESULTS: The mean follow-up time was 5.2 years. At each follow-up, there was no difference in the HHS and VAS between the 2 groups. The neck-shaft angle, offset, vertical height of the rotational center and limb lengthening were lower in the M/L Taper group than in the LCU group (P<0.001). The Engh total score was lower in the LCU group (P=0.039). Significantly higher (P<0.001) BMDs were observed in the M/L Taper group in Gruen zones 1, 2, and 6. significantly lower (P<0.001) BMDs were observed in the M/L Taper group in Gruen zones 3 and 5. CONCLUSIONS: Due to the increased postoperative neck-shaft angle, the full coated dual-wedge classic stem was prone to cause lower limb lengthening. The proximal coated single-wedge new stem patients were more likely to have an insufficient postoperative neck length. The new stem achieved load transfer and proximal fixation, leading to better proximal femoral bone preservation is more in line with human biomechanical characteristics. |
---|