Cargando…

Mass Transfer Accompanying Coalescence of Surfactant-Laden and Surfactant-Free Drop in a Microfluidic Channel

[Image: see text] The coalescence of two different drops, one surfactant-laden and the other surfactant-free, was studied under the condition of confined flow in a microchannel. The coalescence was accompanied by penetration of the surfactant-free drop into the surfactant-laden drop because of the d...

Descripción completa

Detalles Bibliográficos
Autores principales: Kovalchuk, Nina M., Reichow, Marten, Frommweiler, Thomas, Vigolo, Daniele, Simmons, Mark J. H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2019
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7007256/
https://www.ncbi.nlm.nih.gov/pubmed/31268330
http://dx.doi.org/10.1021/acs.langmuir.9b00843
_version_ 1783495292875702272
author Kovalchuk, Nina M.
Reichow, Marten
Frommweiler, Thomas
Vigolo, Daniele
Simmons, Mark J. H.
author_facet Kovalchuk, Nina M.
Reichow, Marten
Frommweiler, Thomas
Vigolo, Daniele
Simmons, Mark J. H.
author_sort Kovalchuk, Nina M.
collection PubMed
description [Image: see text] The coalescence of two different drops, one surfactant-laden and the other surfactant-free, was studied under the condition of confined flow in a microchannel. The coalescence was accompanied by penetration of the surfactant-free drop into the surfactant-laden drop because of the difference in the capillary pressure and Marangoni flows causing a film of surfactant-laden liquid to spread over the surfactant-free drop. The penetration rate was dependent on the drop order, with considerably better penetration observed for the case when the surfactant-laden drop goes first. The penetration rate was found to increase with an increase of interfacial tension difference between the two drops, an increase of flow rate and drop confinement in the channel (for the case of the surfactant-laden drop going first), an increase of viscosity of the continuous phase, and a decrease of viscosity of the dispersed phase. Analysis of flow patterns inside the coalescing drops has shown that, unlike coalescence of identical drops, only two vortices are formed by asymmetrical coalescence, centered inside the surfactant-free drop. The vortices were accelerated by the flow of the continuous phase if the surfactant-laden drop preceded the surfactant-free one, increasing the rate of penetration; the opposite was observed if the drop order was reversed. The mixing patterns on a longer time scale were also dependent on the drop order, with better mixing being observed for the case when the surfactant-laden drop goes first.
format Online
Article
Text
id pubmed-7007256
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-70072562020-02-10 Mass Transfer Accompanying Coalescence of Surfactant-Laden and Surfactant-Free Drop in a Microfluidic Channel Kovalchuk, Nina M. Reichow, Marten Frommweiler, Thomas Vigolo, Daniele Simmons, Mark J. H. Langmuir [Image: see text] The coalescence of two different drops, one surfactant-laden and the other surfactant-free, was studied under the condition of confined flow in a microchannel. The coalescence was accompanied by penetration of the surfactant-free drop into the surfactant-laden drop because of the difference in the capillary pressure and Marangoni flows causing a film of surfactant-laden liquid to spread over the surfactant-free drop. The penetration rate was dependent on the drop order, with considerably better penetration observed for the case when the surfactant-laden drop goes first. The penetration rate was found to increase with an increase of interfacial tension difference between the two drops, an increase of flow rate and drop confinement in the channel (for the case of the surfactant-laden drop going first), an increase of viscosity of the continuous phase, and a decrease of viscosity of the dispersed phase. Analysis of flow patterns inside the coalescing drops has shown that, unlike coalescence of identical drops, only two vortices are formed by asymmetrical coalescence, centered inside the surfactant-free drop. The vortices were accelerated by the flow of the continuous phase if the surfactant-laden drop preceded the surfactant-free one, increasing the rate of penetration; the opposite was observed if the drop order was reversed. The mixing patterns on a longer time scale were also dependent on the drop order, with better mixing being observed for the case when the surfactant-laden drop goes first. American Chemical Society 2019-06-21 2019-07-16 /pmc/articles/PMC7007256/ /pubmed/31268330 http://dx.doi.org/10.1021/acs.langmuir.9b00843 Text en Copyright © 2019 American Chemical Society This is an open access article published under a Creative Commons Attribution (CC-BY) License (http://pubs.acs.org/page/policy/authorchoice_ccby_termsofuse.html) , which permits unrestricted use, distribution and reproduction in any medium, provided the author and source are cited.
spellingShingle Kovalchuk, Nina M.
Reichow, Marten
Frommweiler, Thomas
Vigolo, Daniele
Simmons, Mark J. H.
Mass Transfer Accompanying Coalescence of Surfactant-Laden and Surfactant-Free Drop in a Microfluidic Channel
title Mass Transfer Accompanying Coalescence of Surfactant-Laden and Surfactant-Free Drop in a Microfluidic Channel
title_full Mass Transfer Accompanying Coalescence of Surfactant-Laden and Surfactant-Free Drop in a Microfluidic Channel
title_fullStr Mass Transfer Accompanying Coalescence of Surfactant-Laden and Surfactant-Free Drop in a Microfluidic Channel
title_full_unstemmed Mass Transfer Accompanying Coalescence of Surfactant-Laden and Surfactant-Free Drop in a Microfluidic Channel
title_short Mass Transfer Accompanying Coalescence of Surfactant-Laden and Surfactant-Free Drop in a Microfluidic Channel
title_sort mass transfer accompanying coalescence of surfactant-laden and surfactant-free drop in a microfluidic channel
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7007256/
https://www.ncbi.nlm.nih.gov/pubmed/31268330
http://dx.doi.org/10.1021/acs.langmuir.9b00843
work_keys_str_mv AT kovalchukninam masstransferaccompanyingcoalescenceofsurfactantladenandsurfactantfreedropinamicrofluidicchannel
AT reichowmarten masstransferaccompanyingcoalescenceofsurfactantladenandsurfactantfreedropinamicrofluidicchannel
AT frommweilerthomas masstransferaccompanyingcoalescenceofsurfactantladenandsurfactantfreedropinamicrofluidicchannel
AT vigolodaniele masstransferaccompanyingcoalescenceofsurfactantladenandsurfactantfreedropinamicrofluidicchannel
AT simmonsmarkjh masstransferaccompanyingcoalescenceofsurfactantladenandsurfactantfreedropinamicrofluidicchannel