Corrective Intra-Articular Osteotomy Using a 3D-Printed Model and Induced Membrane Technique for AO/OTA C3 Distal Femur Fracture with Articular Malunion and Metaphyseal Nonunion
Comminuted distal femur fracture is a challenging injury, and care must be taken to reduce the articular fragment and acquire the sufficient stability for the metaphyseal comminution. We report the case of a AO/OTA C3-type distal femur fracture with articular malunion and metaphyseal nonunion. Artic...
Autores principales: | Saka, Natsumi, Watanabe, Yoshinobu, Sasaki, Gen, Kawano, Hirotaka |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7007957/ https://www.ncbi.nlm.nih.gov/pubmed/32047684 http://dx.doi.org/10.1155/2020/1250231 |
Ejemplares similares
-
Intra-Articular Osteotomy for Distal Humerus Malunion
por: Marti, René K., et al.
Publicado: (2009) -
Double plating for long-standing nonunion of the humeral shaft complicated with metaphyseal bone defect and deformity: A case report
por: Saka, Natsumi, et al.
Publicado: (2021) -
Extra-Articular Corrective Osteotomy for Malunion of Intra-Articular Fracture of the Elbow in a Child: A Case Report
por: Shibayama, Hiroki, et al.
Publicado: (2022) -
Osteotomy and Autograft Lengthening for Intra-Articular Malunion of the Proximal Ulna: A Case Report
por: Doornberg, Job N., et al.
Publicado: (2009) -
Malunion of the Acetabulum Treated by Intra-articular Buttress
por: Saragaglia, D., et al.
Publicado: (2020)