Cargando…

Development of Sound Field Audiometry System for Small Audiometric Booths and Comparison of Its Equivalence With Traditional System

OBJECTIVES: Sound field (SF) audiometry tests are usually conducted in audiometric booths measuring greater than 2×2 m in size. However, most private ENT clinics carry about 1×1-m-sized audiometric booths, making SF audiometry testing difficult to perform. The aims of this study were to develop an S...

Descripción completa

Detalles Bibliográficos
Autores principales: Jung, Eun Kyung, Choi, Young Mi, Kim, Eun Jung, Lee, Sungsu, Cho, Hyong-Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Otorhinolaryngology-Head and Neck Surgery 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7010499/
https://www.ncbi.nlm.nih.gov/pubmed/31302989
http://dx.doi.org/10.21053/ceo.2019.00577
_version_ 1783495886367621120
author Jung, Eun Kyung
Choi, Young Mi
Kim, Eun Jung
Lee, Sungsu
Cho, Hyong-Ho
author_facet Jung, Eun Kyung
Choi, Young Mi
Kim, Eun Jung
Lee, Sungsu
Cho, Hyong-Ho
author_sort Jung, Eun Kyung
collection PubMed
description OBJECTIVES: Sound field (SF) audiometry tests are usually conducted in audiometric booths measuring greater than 2×2 m in size. However, most private ENT clinics carry about 1×1-m-sized audiometric booths, making SF audiometry testing difficult to perform. The aims of this study were to develop an SF audiometry system for use in smaller audiometric booths and compare its performance with traditional system. METHODS: The newly developed SF audiometry system can yield an SF signal at a distance of about 30 cm from the subject’s ears. Its height can be adjusted according to the subject’s head height. We compared SF hearing results between the new SF system and the traditional SF audiometry system in 20 adults with normal hearing (40 ears) and 24 adults with impaired hearing levels (38 ears) who wore hearing aids. Comparative parameters included warble tone audiometry threshold, a speech reception threshold (SRT), and a speech discrimination score (SDS). For statistical analysis, paired t-test was used. The equivalence of both SF systems was tested using two one-sided test (TOST) with a margin of 5 dB (normal hearing participants) and 10 dB (hearing aids wearing participants). RESULTS: Among participants with normal hearing, warble tone hearing thresholds of 0.5, 1, 2, and 4 kHz, average values of these four frequencies, and SRT were similar between the two systems (all P>0.05). Participants with hearing aids showed similar warble tone threshold and SRT (P>0.05) in both systems except for threshold of 4 kHz (P=0.033). SDS was significantly higher in the newly developed system (P<0.05). TOST results showed equivalent SF audiometry results using either system. CONCLUSION: Audiometric results of the newly developed SF audiometry system were equivalent to those of a traditional system. Therefore, the small SF audiometry system can be used at small audiometric booths present in most private ENT clinics.
format Online
Article
Text
id pubmed-7010499
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Society of Otorhinolaryngology-Head and Neck Surgery
record_format MEDLINE/PubMed
spelling pubmed-70104992020-02-20 Development of Sound Field Audiometry System for Small Audiometric Booths and Comparison of Its Equivalence With Traditional System Jung, Eun Kyung Choi, Young Mi Kim, Eun Jung Lee, Sungsu Cho, Hyong-Ho Clin Exp Otorhinolaryngol Original Article OBJECTIVES: Sound field (SF) audiometry tests are usually conducted in audiometric booths measuring greater than 2×2 m in size. However, most private ENT clinics carry about 1×1-m-sized audiometric booths, making SF audiometry testing difficult to perform. The aims of this study were to develop an SF audiometry system for use in smaller audiometric booths and compare its performance with traditional system. METHODS: The newly developed SF audiometry system can yield an SF signal at a distance of about 30 cm from the subject’s ears. Its height can be adjusted according to the subject’s head height. We compared SF hearing results between the new SF system and the traditional SF audiometry system in 20 adults with normal hearing (40 ears) and 24 adults with impaired hearing levels (38 ears) who wore hearing aids. Comparative parameters included warble tone audiometry threshold, a speech reception threshold (SRT), and a speech discrimination score (SDS). For statistical analysis, paired t-test was used. The equivalence of both SF systems was tested using two one-sided test (TOST) with a margin of 5 dB (normal hearing participants) and 10 dB (hearing aids wearing participants). RESULTS: Among participants with normal hearing, warble tone hearing thresholds of 0.5, 1, 2, and 4 kHz, average values of these four frequencies, and SRT were similar between the two systems (all P>0.05). Participants with hearing aids showed similar warble tone threshold and SRT (P>0.05) in both systems except for threshold of 4 kHz (P=0.033). SDS was significantly higher in the newly developed system (P<0.05). TOST results showed equivalent SF audiometry results using either system. CONCLUSION: Audiometric results of the newly developed SF audiometry system were equivalent to those of a traditional system. Therefore, the small SF audiometry system can be used at small audiometric booths present in most private ENT clinics. Korean Society of Otorhinolaryngology-Head and Neck Surgery 2020-02 2019-07-16 /pmc/articles/PMC7010499/ /pubmed/31302989 http://dx.doi.org/10.21053/ceo.2019.00577 Text en Copyright © 2020 by Korean Society of Otorhinolaryngology-Head and Neck Surgery This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jung, Eun Kyung
Choi, Young Mi
Kim, Eun Jung
Lee, Sungsu
Cho, Hyong-Ho
Development of Sound Field Audiometry System for Small Audiometric Booths and Comparison of Its Equivalence With Traditional System
title Development of Sound Field Audiometry System for Small Audiometric Booths and Comparison of Its Equivalence With Traditional System
title_full Development of Sound Field Audiometry System for Small Audiometric Booths and Comparison of Its Equivalence With Traditional System
title_fullStr Development of Sound Field Audiometry System for Small Audiometric Booths and Comparison of Its Equivalence With Traditional System
title_full_unstemmed Development of Sound Field Audiometry System for Small Audiometric Booths and Comparison of Its Equivalence With Traditional System
title_short Development of Sound Field Audiometry System for Small Audiometric Booths and Comparison of Its Equivalence With Traditional System
title_sort development of sound field audiometry system for small audiometric booths and comparison of its equivalence with traditional system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7010499/
https://www.ncbi.nlm.nih.gov/pubmed/31302989
http://dx.doi.org/10.21053/ceo.2019.00577
work_keys_str_mv AT jungeunkyung developmentofsoundfieldaudiometrysystemforsmallaudiometricboothsandcomparisonofitsequivalencewithtraditionalsystem
AT choiyoungmi developmentofsoundfieldaudiometrysystemforsmallaudiometricboothsandcomparisonofitsequivalencewithtraditionalsystem
AT kimeunjung developmentofsoundfieldaudiometrysystemforsmallaudiometricboothsandcomparisonofitsequivalencewithtraditionalsystem
AT leesungsu developmentofsoundfieldaudiometrysystemforsmallaudiometricboothsandcomparisonofitsequivalencewithtraditionalsystem
AT chohyongho developmentofsoundfieldaudiometrysystemforsmallaudiometricboothsandcomparisonofitsequivalencewithtraditionalsystem