Cargando…

Three-layer heterogeneous mammographic phantoms for Monte Carlo simulation of normalized glandular dose coefficients in mammography

Normalized glandular dose (DgN) coefficients obtained using homogeneous breast phantoms are commonly used in breast dosimetry for mammography. However, glandular tissue is heterogeneously distributed in the breast. This study aimed to construct three-layer heterogeneous mammographic phantoms (THEPs)...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Tien-Yu, Lai, Kuan-Jen, Tu, Chun-Yuan, Wu, Jay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7010737/
https://www.ncbi.nlm.nih.gov/pubmed/32042071
http://dx.doi.org/10.1038/s41598-020-59317-4
_version_ 1783495930910081024
author Chang, Tien-Yu
Lai, Kuan-Jen
Tu, Chun-Yuan
Wu, Jay
author_facet Chang, Tien-Yu
Lai, Kuan-Jen
Tu, Chun-Yuan
Wu, Jay
author_sort Chang, Tien-Yu
collection PubMed
description Normalized glandular dose (DgN) coefficients obtained using homogeneous breast phantoms are commonly used in breast dosimetry for mammography. However, glandular tissue is heterogeneously distributed in the breast. This study aimed to construct three-layer heterogeneous mammographic phantoms (THEPs) to examine the effect of glandular distribution on DgN coefficient. Each layer of THEPs was set to 25%, 50%, or 75% glandular fraction to emulate heterogeneous glandular distribution. Monte Carlo simulation was performed to attain mean glandular dose (MGD) and air kerma at 22–36 kVp and W/Al, W/Rh, and W/Ag target–filter combinations. The heterogeneous DgN coefficient was calculated as functions of the mean glandular fraction (MGF), breast thickness, tube voltage, and half-value layer. At 50% MGF, the heterogeneous DgN coefficients for W/Al, W/Rh, and W/Ag differed by 40.3%, 36.7%, and 31.2%. At 9-cm breast thickness, the DgN values of superior and inferior glandular distributions were 25.4% higher and 29.2% lower than those of uniform distribution. The proposed THEPs can be integrated with conventional breast dosimetry to consider the heterogeneous glandular distribution in clinical practice.
format Online
Article
Text
id pubmed-7010737
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-70107372020-02-21 Three-layer heterogeneous mammographic phantoms for Monte Carlo simulation of normalized glandular dose coefficients in mammography Chang, Tien-Yu Lai, Kuan-Jen Tu, Chun-Yuan Wu, Jay Sci Rep Article Normalized glandular dose (DgN) coefficients obtained using homogeneous breast phantoms are commonly used in breast dosimetry for mammography. However, glandular tissue is heterogeneously distributed in the breast. This study aimed to construct three-layer heterogeneous mammographic phantoms (THEPs) to examine the effect of glandular distribution on DgN coefficient. Each layer of THEPs was set to 25%, 50%, or 75% glandular fraction to emulate heterogeneous glandular distribution. Monte Carlo simulation was performed to attain mean glandular dose (MGD) and air kerma at 22–36 kVp and W/Al, W/Rh, and W/Ag target–filter combinations. The heterogeneous DgN coefficient was calculated as functions of the mean glandular fraction (MGF), breast thickness, tube voltage, and half-value layer. At 50% MGF, the heterogeneous DgN coefficients for W/Al, W/Rh, and W/Ag differed by 40.3%, 36.7%, and 31.2%. At 9-cm breast thickness, the DgN values of superior and inferior glandular distributions were 25.4% higher and 29.2% lower than those of uniform distribution. The proposed THEPs can be integrated with conventional breast dosimetry to consider the heterogeneous glandular distribution in clinical practice. Nature Publishing Group UK 2020-02-10 /pmc/articles/PMC7010737/ /pubmed/32042071 http://dx.doi.org/10.1038/s41598-020-59317-4 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Chang, Tien-Yu
Lai, Kuan-Jen
Tu, Chun-Yuan
Wu, Jay
Three-layer heterogeneous mammographic phantoms for Monte Carlo simulation of normalized glandular dose coefficients in mammography
title Three-layer heterogeneous mammographic phantoms for Monte Carlo simulation of normalized glandular dose coefficients in mammography
title_full Three-layer heterogeneous mammographic phantoms for Monte Carlo simulation of normalized glandular dose coefficients in mammography
title_fullStr Three-layer heterogeneous mammographic phantoms for Monte Carlo simulation of normalized glandular dose coefficients in mammography
title_full_unstemmed Three-layer heterogeneous mammographic phantoms for Monte Carlo simulation of normalized glandular dose coefficients in mammography
title_short Three-layer heterogeneous mammographic phantoms for Monte Carlo simulation of normalized glandular dose coefficients in mammography
title_sort three-layer heterogeneous mammographic phantoms for monte carlo simulation of normalized glandular dose coefficients in mammography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7010737/
https://www.ncbi.nlm.nih.gov/pubmed/32042071
http://dx.doi.org/10.1038/s41598-020-59317-4
work_keys_str_mv AT changtienyu threelayerheterogeneousmammographicphantomsformontecarlosimulationofnormalizedglandulardosecoefficientsinmammography
AT laikuanjen threelayerheterogeneousmammographicphantomsformontecarlosimulationofnormalizedglandulardosecoefficientsinmammography
AT tuchunyuan threelayerheterogeneousmammographicphantomsformontecarlosimulationofnormalizedglandulardosecoefficientsinmammography
AT wujay threelayerheterogeneousmammographicphantomsformontecarlosimulationofnormalizedglandulardosecoefficientsinmammography